TAPE390_DISPLAY(8) | System Manager's Manual | TAPE390_DISPLAY(8) |
NAME¶
tape390_display - display messages on the display unit of a zSeries tape device.SYNOPSIS¶
- tape390_display
- [-b|--blink]
DESCRIPTION¶
tape390_display displays one or two 8-byte messages on the display unit of a zSeries tape device. Characters to be displayed include capital letters A-Z, numerics 0-9 and special characters. However some special characters may not display on all device types. The characters that should display on model 3490 are:OPTIONS¶
- -h or --help
- Print help text.
- -b or --blink
- Display message1 repeatedly for 2 seconds at
half-second intervals. This option is ignored if two messages are
specified on command line.
- -l or --load
- If this option is given the display request will cause a
load request to be sent to the automatic tape loader (if installed). The
next indexed tape will then be loaded if the loader is in 'system' mode.
Otherwise the request is ignored.
- -q or --quiet
- This option causes the command to run in quiet mode which
will suppress all warning messages.
- -t type or --type type
- Set the type of the message to be displayed. This
influences how long the message(s) stay on the display. Available types
are:
- standard
- The message(s) stay displayed until the drive executes the next tape movement command. This is the default.
- load
- Displays the message(s) until a tape is loaded. If there already is a tape loaded to the device, nothing is displayed at all.
- unload
- This will display the message(s) until currently loaded tape is unloaded. Again, if the drive is currently unloaded there is no output at all.
- noop
- For testing purposes only, this will access the drive but won't do anything at all (no operation). This doesn't seem to work with 3590 tape devices.
- reload
- This display type requires two messages. The first message is displayed as long as there is a tape loaded up to the time the unload operation is completed (or, if there isn't a tape loaded, it will be ignored). The second message is displayed as soon as a tape gets loaded into the drive.
- -v or --version
- Print the S/390 tools package version, the utility version
and exit.
- message1 [ message2 ]
- The message(s) to be displayed. They stay displayed until
either the ending condition for the message type takes place or the
display is updated with another message.
- device
- The tape device on which the message(s) will be displayed,
e.g.:
EXAMPLES¶
tape390_display --blink --type unload "TESTING" /dev/ntibm0Let the message TESTING blink on the display
of the tape unit until the tape is removed (or another message is given). If
there is no tape in the drive, nothing happens.
tape390_display "BACKUP" "COMPLETE"
/dev/ntibm0
This will display the messages BACKUP and
COMPLETE each for 2 seconds until the tape is moved, ejected or (if there
isn't a tape in the device) inserted.
tape390_display --type reload "UNLOAD" "LOAD"
/dev/ntibm 0
The UNLOAD message will be displayed if there
is a tape inserted and as long as the tape isn't removed. After that the LOAD
message is displayed until a tape is inserted. If there is no tape inserted
when the command
tape390_display --load --type load "LOADING" /dev/ntibm0
Causes the device to display the message
LOADING until a tape is inserted and to instruct the automatic stacker to load
the next tape (if the mode of operation is system). If there already is
a tape loaded, nothing will happen at all.
AUTHOR¶
This man-page was written by Despina Papadopoulou<despina_p@de.ibm.com> Updates by Stefan Bader<shbader@de.ibm.com>