UPSSTATS.HTML(5) | NUT Manual | UPSSTATS.HTML(5) |
NAME¶
upsstats.html - HTML template for Network UPS Tools upsstatsDESCRIPTION¶
This file is used by upsstats.cgi(8) to generate status pages. Certain commands are recognized, and will be replaced with various status elements on the fly.FORMATTING¶
Commands can be placed anywhere on a line, but must start and end with @. Any extra characters before or after the commands will be passed through unchanged. It is allowed to use more than one command on a single line, as long as each command has its own start and end character. If you need to use the @ sign, use @ to prevent it from being treated as a start character.BLOCK CONTROL¶
Some commands begin blocks - sections of the template that will be included, excluded, or repeated depending on certain parameters.BLOCK CONTROL - ITERATION¶
@FOREACHUPS@Starts a block that will be repeated for each
MONITOR directive in the hosts.conf(5). This is how you can generate
pages that monitor all of your systems simultaneously.
@ENDFOR@
Ends a FOREACHUPS block.
BLOCK CONTROL - MATCHING SPECIFIC CASES¶
@IFSUPP var@*Starts a block that will only be printed if
the variable var is supported by the current UPS. This is generally used to
suppress "not supported" messages by avoiding the label and variable
call entirely.
@IFEQ var value@
Starts a block if the value returned from the
variable var matches value.
@IFBETWEEN varlow varhigh varvalue@
Starts a block if the value returned by the
variable varvalue is between the values returned by the variables
varlow and varhigh.
@ELSE@
If the previous IF-command did not match,
perform this instead.
@ENDIF@
Ends an IF/ELSE-block.
BLOCK CONTROL - ADVANCED EXPRESSIONS¶
Even though the parser is pretty limited, it’s still possible to create rather advanced expressions. The key to this is the fact that multiple block control commands are AND:ed. This is illustrated with an example (more examples are available in upsstats.html).@IFSUPP ambient.humidity@ @IFSUPP ambient.temperature@ This UPS knows both ambient temperature and humidity. @ELSE@ @IFSUPP ambient.humidity@ This UPS only knows ambient humidity. @ELSE@ @IFSUPP ambient.temperature@ This UPS only knows ambient temperature. @ELSE@ This UPS knows nothing, how annoying. @ENDIF@
OTHER COMMANDS¶
@AMBTEMP@Insert the ambient temperature in the current
temperature scale.
@DATE format@
Insert the current date and time. The format
string is passed to strftime, so almost anything is possible. See
strftime(3) for possible values.
@DEGREES@
Insert the entity for degrees (°) and
either C or F depending on the current temperature scale.
@HOST@
Insert the designation of the host being
monitored, like myups@localhost.
@HOSTDESC@
Insert the hout’s description from
hosts.conf(5).
@HOSTLINK@
Insert a link to upsstats.cgi with the
"host" variable set to the current UPS. This is only useful within a
FOREACHUPS block.
@IMG varname @
Insert an IMG SRC to upsimage.cgi(8)
for one of these status variables:
battery.charge
Battery charge - a percentage
battery.voltage
The charge on the battery in volts
input.frequency
Incoming utility frequency (Hz)
input.voltage
Incoming utility voltage
input.L1-L2.voltage
Incoming voltage, L1-L2 (3phase)
input.L2-L3.voltage
Incoming voltage, L2-L3 (3phase)
input.L3-L1.voltage
Incoming voltage, L3-L1 (3phase)
output.frequency
Outgoing utility frequency (Hz)
output.voltage
Outgoing voltage (from the UPS)
output.L1-L2.voltage
Outgoing voltage, L1-L2 (3phase)
output.L2-L3.voltage
Outgoing voltage, L2-L3 (3phase)
output.L3-L1.voltage
Outgoing voltage, L3-L1 (3phase)
output.L1.power.percent
UPS load, L1 (3phase)
output.L2.power.percent
UPS load, L2 (3phase)
output.L3.power.percent
UPS load, L3 (3phase)
ups.load
UPS load - percentage
ups.temperature
UPS temperature
background color
scale_num_col
scale number color
summary_col
summary color (number at the bottom)
ok_zone_maj_col
major scale color for the normal
("ok") zone
ok_zone_min_col
minor scale color for the normal
("ok") zone
neutral_zone_maj_col
major scale color for the neutral zone
neutral_zone_min_col
minor scale color for the neutral zone
warn_zone_maj_col
major scale color for the warning zone
warn_zone_min_col
minor scale color for the warning zone
bar_col
the color of the bar in the middle
@IMG battery.charge@ @IMG battery.charge back_col=0xff00ff bar_col=0xaabbcc@ @IMG input.voltage ok_zone_maj_col=0x123456@
Insert the META header magic for refreshing
the page if that variable has been set by the browser. This needs to be in the
HEAD section of the page.
@STATUS@
Expand the abbreviations in the ups.status
variable - OL becomes "On line", OB becomes "On battery",
and so on.
@STATUSCOLOR@
Insert red, green, or yellow color triplets
depending on the severity of the current UPS status. Normal operations are
green, warnings like voltage trim/boost or "off" are yellow, and
other events like being on battery or having a low battery are red.
@VAR varname@
Insert the current value of the status
variable varname on the host being monitored, or "Not
supported".
@RUNTIME@
Inserts the current runtime, in hh:mm:ss
format.
@TEMPC@
Use the Celsius scale for temperature data
(default).
@TEMPF@
Use the Fahrenheit scale for temperature
data.
@UPSTEMP@
Insert the UPS temperature in the current
scale.
@BATTTEMP@
Insert the battery temperature in the current
scale.
@UTILITYCOLOR@
Obsoleted. Use IFBETWEEN instead (see example
in upsstats.html).
@VERSION@
Insert the version number of the
software.
OTHER TEMPLATES¶
upsstats.cgi(8) will also open a file called upsstats-single.html if you call it with "host=" set in the URL. That file uses the same rules and techniques documented here.SEE ALSO¶
upsstats.cgi(8), upsimage.cgi(8)Internet resources:¶
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/05/22/2012 | Network UPS Tools |