NAME¶
ipmitool - utility for controlling IPMI-enabled devices
SYNOPSIS¶
ipmitool [
-c|
-h|
-d N|
-v|
-V]
-I open <
command>
ipmitool [
-c|
-h|
-v|
-V]
-I lan
-H <
hostname>
[
-p <
port>]
[
-U <
username>]
[
-A <
authtype>]
[
-L <
privlvl>]
[
-a|
-E|
-P|
-f <
password>]
[
-o <
oemtype>]
[
-O <
sel oem>]
[
-e <
esc_char>]
<
command>
ipmitool [
-c|
-h|
-v|
-V]
-I lanplus
-H <
hostname>
[
-p <
port>]
[
-U <
username>]
[
-L <
privlvl>]
[
-a|
-E|
-P|
-f <
password>]
[
-o <
oemtype>]
[
-O <
sel oem>]
[
-C <
ciphersuite>]
[
-K|
-k <
kg_key>]
[
-y <
hex_kg_key>]
[
-e <
esc_char>]
<
command>
DESCRIPTION¶
This program lets you manage Intelligent Platform Management Interface (IPMI)
functions of either the local system, via a kernel device driver, or a remote
system, using IPMI V1.5 and IPMI v2.0. These functions include printing FRU
information, LAN configuration, sensor readings, and remote chassis power
control.
IPMI management of a local system interface requires a compatible IPMI kernel
driver to be installed and configured. On Linux this driver is called
OpenIPMI and it is included in standard distributions. On Solaris this
driver is called
BMC and is included in Solaris 10. Management of a
remote station requires the IPMI-over-LAN interface to be enabled and
configured. Depending on the particular requirements of each system it may be
possible to enable the LAN interface using ipmitool over the system interface.
OPTIONS¶
- -a
- Prompt for the remote server password.
- -A <authtype>
- Specify an authentication type to use during IPMIv1.5
lan session activation. Supported types are NONE, PASSWORD, MD2,
MD5, or OEM.
- -c
- Present output in CSV (comma separated variable) format.
This is not available with all commands.
- -e <sol_escape_char>
- Use supplied character for SOL session escape character.
The default is to use ~ but this can conflict with ssh
sessions.
- -k <key>
- Use supplied Kg key for IPMIv2 authentication. The default
is not to use any Kg key.
- -y <hex key>
- Use supplied Kg key for IPMIv2 authentication. The key is
expected in hexadecimal format and can be used to specify keys with
non-printable characters. E.g. '-k PASSWORD' and '-y 50415353574F5244' are
equivalent. The default is not to use any Kg key.
- -C <ciphersuite>
- The remote server authentication, integrity, and encryption
algorithms to use for IPMIv2 lanplus connections. See table 22-19
in the IPMIv2 specification. The default is 3 which specifies
RAKP-HMAC-SHA1 authentication, HMAC-SHA1-96 integrity, and AES-CBC-128
encryption algorightms.
- -E
- The remote server password is specified by the environment
variable IPMI_PASSWORD.
- -f <password_file>
- Specifies a file containing the remote server password. If
this option is absent, or if password_file is empty, the password will
default to NULL.
- -h
- Get basic usage help from the command line.
- -H <address>
- Remote server address, can be IP address or hostname. This
option is required for lan and lanplus interfaces.
- -I <interface>
- Selects IPMI interface to use. Supported interfaces that
are compiled in are visible in the usage help output.
- -L <privlvl>
- Force session privilege level. Can be CALLBACK, USER,
OPERATOR, ADMINISTRATOR. Default is ADMINISTRATOR.
- -m <local_address>
- Set the local IPMB address. The default is 0x20 and there
should be no need to change it for normal operation.
- -o <oemtype>
- Select OEM type to support. This usually involves minor
hacks in place in the code to work around quirks in various BMCs from
various manufacturers. Use -o list to see a list of current
supported OEM types.
- -O <sel oem>
- Open selected file and read OEM SEL event descriptions to
be used during SEL listings. See examples in contrib dir for file
format.
- -p <port>
- Remote server UDP port to connect to. Default is 623.
- -P <password>
- Remote server password is specified on the command line. If
supported it will be obscured in the process list. Note! Specifying
the password as a command line option is not recommended.
- -S <sdr_cache_file>
- Use local file for remote SDR cache. Using a local SDR
cache can drastically increase performance for commands that require
knowledge of the entire SDR to perform their function. Local SDR cache
from a remote system can be created with the sdr dump command.
- -t <target_address>
- Bridge IPMI requests to the remote target address.
- -U <username>
- Remote server username, default is NULL user.
- -d N
- Use device number N to specify the /dev/ipmiN (or
/dev/ipmi/N or /dev/ipmidev/N) device to use for in-band BMC
communication. Used to target a specific BMC on a multi-node, multi-BMC
system through the ipmi device driver interface. Default is 0.
- -v
- Increase verbose output level. This option may be specified
multiple times to increase the level of debug output. If given three times
you will get hexdumps of all incoming and outgoing packets.
- -V
- Display version information.
If no password method is specified then ipmitool will prompt the user for a
password. If no password is entered at the prompt, the remote server password
will default to NULL.
SECURITY¶
There are several security issues be be considered before enabling the IPMI LAN
interface. A remote station has the ability to control a system's power state
as well as being able to gather certain platform information. To reduce
vulnerability it is strongly advised that the IPMI LAN interface only be
enabled in 'trusted' environments where system security is not an issue or
where there is a dedicated secure 'management network'.
Further it is strongly advised that you should not enable IPMI for remote access
without setting a password, and that that password should not be the same as
any other password on that system.
When an IPMI password is changed on a remote machine with the IPMIv1.5
lan interface the new password is sent across the network as clear
text. This could be observed and then used to attack the remote system. It is
thus recommended that IPMI password management only be done over IPMIv2.0
lanplus interface or the system interface on the local station.
For IPMI v1.5, the maximum password length is 16 characters. Passwords longer
than 16 characters will be truncated.
For IPMI v2.0, the maximum password length is 20 characters; longer passwords
are truncated.
COMMANDS¶
- help
- This can be used to get command-line help on ipmitool
commands. It may also be placed at the end of commands to get option usage
help.
ipmitool help
Commands:
raw Send a RAW IPMI request and print response
i2c Send an I2C Master Write-Read command and print response
spd Print SPD info from remote I2C device
lan Configure LAN Channels
chassis Get chassis status and set power state
power Shortcut to chassis power commands
event Send events to MC
mc Management Controller status and global enables
sdr Print Sensor Data Repository entries and readings
sensor Print detailed sensor information
fru Print built-in FRU and scan for FRU locators
sel Print System Event Log (SEL)
pef Configure Platform Event Filtering (PEF)
sol Configure and connect IPMIv2.0 Serial-over-LAN
tsol Configure and connect Tyan IPMIv1.5 Serial-over-LAN
isol Configure and connect Intel IPMIv1.5 Serial-over-LAN
user Configure Management Controller users
channel Configure Management Controller channels
session Print session information
sunoem Manage Sun OEM Extensions
kontronoem Manage Kontron OEM Extensions
picmg Run a PICMG/ATA extended command
firewall Configure Firmware Firewall
shell Launch interactive IPMI shell
exec Run list of commands from file
set Set runtime variable for shell and exec
echo Used to echo lines to stdout in scripts
ekanalyzer run FRU-Ekeying analyzer using FRU files
ipmitool chassis help
Chassis Commands: status, power, identify, policy, restart_cause, poh,
bootdev, bootparam, selftest
ipmitool chassis power help
chassis power Commands: status, on, off, cycle, reset, diag, soft
- bmc|mc
- reset <warm|cold>
-
Instructs the BMC to perform a warm or cold reset.
- guid
-
Display the Management Controller Globally Unique IDentifier.
- info
-
Displays information about the BMC hardware, including device revision,
firmware revision, IPMI version supported, manufacturer ID, and
information on additional device support.
- watchdog
-
These commands allow a user to view and change the current state of the
watchdog timer.
- get
-
Show current Watchdog Timer settings and countdown state.
- reset
-
Reset the Watchdog Timer to its most recent state and restart the countdown
timer.
- off
-
Turn off a currently running Watchdog countdown timer.
- selftest
-
Check on the basic health of the BMC by executing the Get Self Test results
command and report the results.
- getenables
-
Displays a list of the currently enabled options for the BMC.
- setenables
<option>=[on|off]
-
Enables or disables the given option. This command is only supported
over the system interface according to the IPMI specification. Currently
supported values for option include:
- recv_msg_intr
-
Receive Message Queue Interrupt
- event_msg_intr
-
Event Message Buffer Full Interrupt
- event_msg
-
Event Message Buffer
- system_event_log
-
System Event Logging
- oem0
-
OEM-Defined option #0
- oem1
-
OEM-Defined option #1
- oem2
-
OEM-Defined option #2
- channel
- authcap <channel number> <max
priv>
-
Displays information about the authentication capabilities of the selected
channel at the specified privilege level.
- Possible privilege levels are:
-
1 Callback level
2 User level
3 Operator level
4 Administrator level
5 OEM Proprietary level
- info [channel number]
-
Displays information about the selected channel. If no channel is given it
will display information about the currently used channel.
> ipmitool channel info
Channel 0xf info:
Channel Medium Type : System Interface
Channel Protocol Type : KCS
Session Support : session-less
Active Session Count : 0
Protocol Vendor ID : 7154
- getaccess <channel number>
[<userid>]
-
Configure the given userid as the default on the given channel number. When
the given channel is subsequently used, the user is identified implicitly
by the given userid.
- setaccess <channel number>
<userid> [< callin=on|off>]
- [<ipmi=on|off>]
[<link= on|off>]
[<privilege=level>]
Configure user access information on the given channel for the given
userid.
- getciphers <ipmi|sol>
[<channel>]
-
Displays the list of cipher suites supported for the given application (ipmi
or sol) on the given channel.
- chassis
- status
-
Displays information regarding the high-level status of the system chassis
and main power subsystem.
- poh
-
This command will return the Power-On Hours counter.
- identify <interval>
-
Control the front panel identify light. Default interval is 15 seconds. Use
0 to turn off. Use "force" to turn on indefinitely.
- restart_cause
-
Query the chassis for the cause of the last system restart.
- selftest
-
Check on the basic health of the BMC by executing the Get Self Test results
command and report the results.
- policy
-
Set the chassis power policy in the event power failure.
- list
-
Return supported policies.
- always-on
-
Turn on when power is restored.
- previous
-
Returned to previous state when power is restored.
- always-off
-
Stay off after power is restored.
- power
-
Performs a chassis control command to view and change the power state.
- status
-
Show current chassis power status.
- on
-
Power up chassis.
- off
-
Power down chassis into soft off (S4/S5 state). WARNING: This command
does not initiate a clean shutdown of the operating system prior to
powering down the system.
- cycle
-
Provides a power off interval of at least 1 second. No action should occur
if chassis power is in S4/S5 state, but it is recommended to check power
state first and only issue a power cycle command if the system power is on
or in lower sleep state than S4/S5.
- reset
-
This command will perform a hard reset.
- diag
-
Pulse a diagnostic interrupt (NMI) directly to the processor(s).
- soft
-
Initiate a soft-shutdown of OS via ACPI. This can be done in a number of
ways, commonly by simulating an overtemperture or by simulating a power
button press. It is necessary for there to be Operating System support for
ACPI and some sort of daemon watching for events for this soft power to
work.
- bootdev <device>
[<clear-cmos= yes|no>]
[<options=help,...>]
-
Request the system to boot from an alternate boot device on next reboot. The
clear-cmos option, if supplied, will instruct the BIOS to clear its
CMOS on the next reboot. Various options may be used to modify the boot
device settings. Run "bootdev none options=help" for a
list of available boot device modifiers/options.
- Currently supported values for <device> are:
- none
-
Do not change boot device
- pxe
-
Force PXE boot
- disk
-
Force boot from BIOS default boot device
- safe
-
Force boot from BIOS default boot device, request Safe Mode
- diag
-
Force boot from diagnostic partition
- cdrom
-
Force boot from CD/DVD
- bios
-
Force boot into BIOS setup
- floppy
-
Force boot from Floppy/primary removable media
- bootparam
-
Get or set various system boot option parameters.
- get <param #>
-
Get boot parameter. Currently supported values for < param #>
are:
0 - Set In Progress
1 - Service Partition Selector
2 - Service Partition Scan
3 - BMC Boot Flag Valid Bit Clearing
4 - Boot Info Acknowledge
5 - Boot Flags
6 - Boot Initiator Info
7 - Boot Initiator Mailbox
- set <option> [value ...]
-
Set boot parameter.
- Currently supported values for <option>
are:
- force_pxe
-
Force PXE boot
- force_disk
-
Force boot from default hard-drive
- force_safe
-
Force boot from default hard-drive, request Safe Mode
- force_diag
-
Force boot from diagnostic partition
- force_cdrom
-
Force boot from CD/DVD
- force_bios
-
Force boot into BIOS setup
- ekanalyzer <command>
<xx=filename1> < xx=filename2>
[<rc=filename3>] ...
-
NOTE : This command can support a maximum of 8 files per command
line
-
filename1 : binary file that stores FRU data of a Carrier or an AMC
module
-
filename2 : binary file that stores FRU data of an AMC module.
-
These binary files can be generated from command:
ipmitool fru read <id> <filename>
-
filename3 : configuration file used for configuring On-Carrier Device
ID
- or OEM GUID. This file is optional.
-
xx : indicates the type of the file. It can take the following
value:
-
oc : On-Carrier device
-
a1 : AMC slot A1
-
a2 : AMC slot A2
-
a3 : AMC slot A3
-
a4 : AMC slot A4
-
b1 : AMC slot B1
-
b2 : AMC slot B2
-
b3 : AMC slot B3
-
b4 : AMC slot B4
-
sm : Shelf Manager
-
-
The available commands for ekanalyzer are:
-
- print [<carrier | power |
all>]
- carrier (default) <oc=filename1>
<oc=filename2> ...
-
Display point to point physical connectivity between carriers and AMC
modules.
Example:
> ipmitool ekanalyzer print carrier oc=fru oc=carrierfru
From Carrier file: fru
Number of AMC bays supported by Carrier: 2
AMC slot B1 topology:
Port 0 =====> On Carrier Device ID 0, Port 16
Port 1 =====> On Carrier Device ID 0, Port 12
Port 2 =====> AMC slot B2, Port 2
AMC slot B2 topology:
Port 0 =====> On Carrier Device ID 0, Port 3
Port 2 =====> AMC slot B1, Port 2
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
From Carrier file: carrierfru
On Carrier Device ID 0 topology:
Port 0 =====> AMC slot B1, Port 4
Port 1 =====> AMC slot B1, Port 5
Port 2 =====> AMC slot B2, Port 6
Port 3 =====> AMC slot B2, Port 7
AMC slot B1 topology:
Port 0 =====> AMC slot B2, Port 0
AMC slot B1 topology:
Port 1 =====> AMC slot B2, Port 1
Number of AMC bays supported by Carrier: 2
- power <xx=filename1>
<xx=filename2> ...
-
Display power supply informations between carrier and AMC modules.
- all <xx=filename>
<xx=filename> ...
-
Display both physical connectivity and power supply of each carrier and AMC
modules.
- frushow <xx=filename>
-
Convert a binary FRU file into human readable text format. Use -v option to
get more display information.
- summary [<match | unmatch |
all>]
- match (default) <xx=filename>
<xx=filename> ...
-
Display only matched results of Ekeying match between an On-Carrier device
and an AMC module or between 2 AMC modules. Example:
> ipmitool ekanalyzer summary match oc=fru b1=amcB1 a2=amcA2
On-Carrier Device vs AMC slot B1
AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
Matching Result
- From On-Carrier Device ID 0
-Channel ID 11 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
Matching Result
- From On-Carrier Device ID 0
-Channel ID 6 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 1 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
On-Carrier Device vs AMC slot A2
AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
Matching Result
- From On-Carrier Device ID 0
-Channel ID 9 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot A2
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 vs AMC slot A2
AMC slot A2 port 2 ==> AMC slot B1 port 2
Matching Result
- From AMC slot B1
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
- To AMC slot A2
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
- unmatch <xx=filename>
<xx=filename> ...
-
Display the unmatched results of Ekeying match between an On-Carrier device
and an AMC module or between 2 AMC modules
- all <xx=filename>
<xx=filename> ...
-
Display both matched result and unmatched results of Ekeying match between
two cards or two modules.
- event
- <predefined event number N>
-
Send a pre-defined test event to the System Event Log. The following events
are included as a means to test the functionality of the System Event Log
component of the BMC (an entry will be added each time the event N
command is executed).
Currently supported values for N are:
1 Temperature: Upper Critical: Going High
2 Voltage Threshold: Lower Critical: Going Low
3 Memory: Correctable ECC
NOTE: These pre-defined events will likely not produce
"accurate" SEL records for a particular system because they will
not be correctly tied to a valid sensor number, but they are sufficient to
verify correct operation of the SEL.
- file <filename>
-
Event log records specified in < filename> will be added to the
System Event Log.
The format of each line in the file is as follows:
<{ EvM Revision} {Sensor Type} {Sensor Num}
{Event Dir/Type} { Event Data 0} {Event Data 1}
{Event Data 2}>[ # COMMENT]
e.g.: 0x4 0x2 0x60 0x1 0x52 0x0 0x0 # Voltage threshold: Lower Critical:
Going Low
EvM Revision - The "Event Message Revision" is 0x04 for
messages that comply with the IPMI 2.0 Specification and 0x03 for messages
that comply with the IPMI 1.0 Specification.
Sensor Type - Indicates the Event Type or Class.
Sensor Num - Represents the 'sensor' within the management
controller that generated the Event Message.
Event Dir/Type - This field is encoded with the event direction as
the high bit (bit 7) and the event type as the low 7 bits. Event direction
is 0 for an assertion event and 1 for a deassertion event.
See the IPMI 2.0 specification for further details on the definitions for
each field.
- <sensorid> <list>
-
Get a list of all the possible Sensor States and pre-defined Sensor State
Shortcuts available for a particular sensor. sensorid is the
character string representation of the sensor and must be enclosed in
double quotes if it includes white space. Several different commands
including ipmitool sensor list may be used to obtain a list that
includes the sensorid strings representing the sensors on a given
system.
> ipmitool -I open event "PS 2T Fan Fault" list
Finding sensor PS 2T Fan Fault... ok
Sensor States:
State Deasserted
State Asserted
Sensor State Shortcuts:
present absent
assert deassert
limit nolimit
fail nofail
yes no
on off
up down
- <sensorid> <sensor state>
[<direction>]
-
Generate a custom event based on existing sensor information. The optional
event direction can be either assert (the default)
or deassert.
> ipmitool event "PS 2T Fan Fault" "State Asserted"
Finding sensor PS 2T Fan Fault... ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Asserted
> ipmitool event "PS 2T Fan Fault" "State Deasserted"
Finding sensor PS 2T Fan Fault... ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Desserted
- exec <filename>
-
Execute ipmitool commands from
filename. Each line is a complete command. The syntax of the commands
are defined by the COMMANDS section in this manpage. Each line may have an
optional comment at the end of the line, delimited with a `#' symbol.
e.g., a command file with two lines:
sdr list # get a list of sdr records
sel list # get a list of sel records
- fru
- print
-
Read all Field Replaceable Unit (FRU) inventory data and extract such
information as serial number, part number, asset tags, and short strings
describing the chassis, board, or product.
- read <fru id> <fru
file>
-
fru id is the digit ID of the FRU (see output of 'fru print').
fru file is the absolute pathname of a file in which to dump the
binary FRU data pertaining to the specified FRU entity.
- write <fru id> <fru
file>
-
fru id is the digit ID of the FRU (see output of 'fru print').
fru file is the absolute pathname of a file from which to pull the
binary FRU data before uploading it to the specified FRU.
- upgEkey <fru id> <fru
file>
-
Update a multirecord FRU location. fru id is the digit ID of the FRU
(see output of 'fru print'). fru file is the absolute pathname of a
file from which to pull the binary FRU data to upload into the specified
multirecord FRU entity.
- edit <fru id>
-
This command provides interactive editing of some supported records, namely
PICMG Carrier Activation Record. fru id is the digit ID of the FRU
(see output of 'fru print'); default is 0.
- edit <fru id> field
<section> < index> <string>
-
This command may be used to set a field string to a new value. It replaces
the FRU data found at index in the specified section with
the supplied string.
- fru id is the digit ID of the FRU (see output of
'fru print').
-
- <section> is a string which refers to FRU
Inventory Information
- Storage Areas and may be refer to:
- c FRU Inventory Chassis Info Area
-
- b FRU Inventory Board Info Area
-
- p FRU Inventory Product Info Area
-
- <index> specifies the field number. Field
numbering starts on the first 'english text' field type. For instance in the
< board> info area field '0' is <Board
Manufacturer> and field '2' is < Board Serial Number>;
see IPMI Platform Management FRU Information Storage Definition v1.0 R1.1
for field locations.
-
- <string> must be the same length as the string
being replaced and must be 8-bit ASCII (0xCx).
-
- edit <fru id> oem iana
< record> <format> [<args>]
-
This command edits the data found in the multirecord area. Support for OEM
specific records is limited.
- firewall
-
This command supports the Firmware Firewall capability. It may be used to
add or remove security-based restrictions on certain commands/command
sub-functions or to list the current firmware firewall restrictions set on
any commands. For each firmware firewall command listed below, parameters
may be included to cause the command to be executed with increasing
granularity on a specific LUN, for a specific NetFn, for a specific IPMI
Command, and finally for a specific command's sub-function (see Appendix H
in the IPMI 2.0 Specification for a listing of any sub-function numbers
that may be associated with a particular command).
Parameter syntax and dependencies are as follows:
[< channel H>] [<lun L> [
<netfn N> [<command C
[<subfn S>]]]]
Note that if "netfn < N>" is specified, then
"lun < L>" must also be specified; if "command
< C>" is specified, then "netfn
<N>" (and therefore "lun < L>")
must also be specified, and so forth.
"channel < H>" is an optional and standalone
parameter. If not specified, the requested operation will be performed on
the current channel. Note that command support may vary from channel to
channel.
Firmware firewall commands:
- info [<Parms as described above>]
-
List firmware firewall information for the specified LUN, NetFn, and Command
(if supplied) on the current or specified channel. Listed information
includes the support, configurable, and enabled bits for the specified
command or commands.
Some usage examples:
- info [<channel H>] [<lun
L>]
-
This command will list firmware firewall information for all NetFns for the
specified LUN on either the current or the specified channel.
- info [<channel H>] [<lun
L> [ < netfn N> ]
-
This command will print out all command information for a single LUN/NetFn
pair.
- info [<channel H>] [<lun
L> [ < netfn N> [<command C] ]]
-
This prints out detailed, human-readable information showing the support,
configurable, and enabled bits for the specified command on the specified
LUN/NetFn pair. Information will be printed about each of the command
subfunctions.
- info [<channel H>] [<lun
L> [ < netfn N> [<command C [<subfn
S>]]]]
-
Print out information for a specific sub-function.
- enable [<Parms as described
above>]
-
This command is used to enable commands for a given NetFn/LUN combination on
the specified channel.
- disable [<Parms as described above>]
[force]
-
This command is used to disable commands for a given NetFn/LUN combination
on the specified channel. Great care should be taken if using the
"force" option so as not to disable the "Set Command
Enables" command.
- reset [<Parms as described above>]
-
This command may be used to reset the firmware firewall back to a state
where all commands and command sub-functions are enabled.
- i2c <i2caddr> <read bytes>
[< write data>]
-
This command may be used to execute raw I2C commands with the Master
Write-Read IPMI command.
- isol
- info
-
Retrieve information about the Intel IPMI v1.5 Serial-Over-LAN
configuration.
- set <parameter>
<value>
-
Configure parameters for Intel IPMI v1.5 Serial-over-LAN.
- Valid parameters and values are:
-
- enabled
- true, false.
- privilege-level
- user, operator, admin, oem.
- bit-rate
- 9.6, 19.2, 38.4, 57.6, 115.2.
- activate
-
Causes ipmitool to enter Intel IPMI v1.5 Serial Over LAN mode. An RMCP+
connection is made to the BMC, the terminal is set to raw mode, and user
input is sent to the serial console on the remote server. On exit, the the
SOL payload mode is deactivated and the terminal is reset to its original
settings.
Special escape sequences are provided to control the SOL session:
- ~. Terminate connection
- ~^Z Suspend ipmitool
- ~^X Suspend ipmitool, but don't restore tty on
restart
- ~B Send break
- ~~ Send the escape character by typing it twice
- ~? Print the supported escape sequences
Note that escapes are only recognized immediately after newline.
- kontronoem
OEM commands specific to Kontron devices.
- setsn
-
Set FRU serial number.
- setmfgdate
-
Set FRU manufacturing date.
- nextboot <boot device>
-
Select the next boot order on the Kontron CP6012.
- lan
These commands will allow you to configure IPMI LAN channels with network
information so they can be used with the ipmitool
lan and
lanplus interfaces.
NOTE: To determine on which channel the LAN
interface is located, issue the `channel info
number' command until you
come across a valid 802.3 LAN channel. For example:
> ipmitool -I open channel info 1
Channel 0x1 info:
Channel Medium Type : 802.3 LAN
Channel Protocol Type : IPMB-1.0
Session Support : session-based
Active Session Count : 8
Protocol Vendor ID : 7154
- print [<channel>]
-
Print the current configuration for the given channel. The default will
print information on the first found LAN channel.
- set <channel number>
<command> < parameter>
-
Set the given command and parameter on the specified channel. Valid
command/parameter options are:
- ipaddr <x.x.x.x>
-
Set the IP address for this channel.
- netmask <x.x.x.x>
-
Set the netmask for this channel.
- macaddr <xx:xx:xx:xx:xx:xx>
-
Set the MAC address for this channel.
- defgw ipaddr <x.x.x.x>
-
Set the default gateway IP address.
- defgw macaddr <xx:xx:xx:xx:xx:xx>
-
Set the default gateway MAC address.
- bakgw ipaddr <x.x.x.x>
-
Set the backup gateway IP address.
- bakgw macaddr <xx:xx:xx:xx:xx:xx>
-
Set the backup gateway MAC address.
- password <pass>
-
Set the null user password.
- snmp <community string>
-
Set the SNMP community string.
- user
-
Enable user access mode for userid 1 (issue the `user' command to display
information about userids for a given channel).
- access <on|off>
-
Set LAN channel access mode.
- alert <on|off>
-
Enable or disable PEF alerting for this channel.
- ipsrc <source>
-
Set the IP address source:
none unspecified
static manually configured static IP address
dhcp address obtained by BMC running DHCP
bios address loaded by BIOS or system software
- arp respond <on|off>
-
Set BMC generated ARP responses.
- arp generate <on|off>
-
Set BMC generated gratuitous ARPs.
- arp interval <seconds>
-
Set BMC generated gratuitous ARP interval.
- vlan id <off|id>
-
Disable VLAN operation or enable VLAN and set the ID.
ID: value of the virtual lan identifier between 1 and 4094 inclusive.
- vlan priority <priority>
-
Set the priority associated with VLAN frames.
ID: priority of the virtual lan frames between 0 and 7 inclusive.
- auth <level,...>
<type, ...>
-
Set the valid authtypes for a given auth level.
Levels: callback, user, operator, admin
Types: none, md2, md5, password, oem
- cipher_privs <privlist>
-
Correlates cipher suite numbers with the maximum privilege level that is
allowed to use it. In this way, cipher suites can restricted to users with
a given privilege level, so that, for example, administrators are required
to use a stronger cipher suite than normal users.
The format of privlist is as follows. Each character represents a
privilege level and the character position identifies the cipher suite
number. For example, the first character represents cipher suite 1 (cipher
suite 0 is reserved), the second represents cipher suite 2, and so on.
privlist must be 15 characters in length.
Characters used in privlist and their associated privilege levels
are:
X Cipher Suite Unused
c CALLBACK
u USER
o OPERATOR
a ADMIN
O OEM
So, to set the maximum privilege for cipher suite 1 to USER and suite 2 to
ADMIN, issue the following command:
> ipmitool -I interface lan set channel cipher_privs
uaXXXXXXXXXXXXX
- alert print [<channel>]
[<alert destination>]
-
Print alert information for the specified channel and destination. The
default will print all alerts for all alert destinations on the first
found LAN channel.
- alert set <channel number>
<alert destination> <command>
<parameter>
-
Set an alert on the given LAN channel and destination. Alert Destinations
are listed via the ' lan alert print' command. Valid
command/parameter options are:
- ipaddr <x.x.x.x>
-
Set alert IP address.
- macaddr <xx:xx:xx:xx:xx:xx>
-
Set alert MAC address.
- gateway <default | backup>
-
Set the channel gateway to use for alerts.
- ack <on | off>
-
Set Alert Acknowledge on or off.
- type <pet | oem1 | oem2>
-
Set the destination type as PET or OEM.
- time <seconds>
-
Set ack timeout or unack retry interval.
- retry <number>
-
Set the number of alert retries.
- stats get [<channel
number>]
-
Retrieve information about the IP connections on the specified channel. The
default will retrieve statistics on the first found LAN channel.
- stats clear [<channel
number>]
-
Clear all IP/UDP/RMCP Statistics to 0 on the specified channel. The default
will clear statistics on the first found LAN channel.
- pef
- info
-
This command will query the BMC and print information about the PEF
supported features.
- status
-
This command prints the current PEF status (the last SEL entry processed by
the BMC, etc).
- policy
-
This command lists the PEF policy table entries. Each policy entry describes
an alert destination. A policy set is a collection of table entries. PEF
alert actions reference policy sets.
- list
-
This command lists the PEF table entries. Each PEF entry relates a sensor
event to an action. When PEF is active, each platform event causes the BMC
to scan this table for entries matching the event, and possible actions to
be taken. Actions are performed in priority order (higher criticality
first).
- picmg <properties>
Run a PICMG/ATA extended command. Get PICMG properties may be used to obtain and
print Extension major version information, PICMG identifier, FRU Device ID and
Max FRU Device ID.
- addrinfo
-
Get address information. This command may return information on the Hardware
address, IPMB-0 Address, FRU ID, Site/Entity ID, and Site/Entity
Type.
- frucontrol <fru id>
<options>
-
Set various control options:
- 0x00 - Cold Reset
-
- 0x01 - Warm Reset
-
- 0x02 - Graceful Reboot
-
- 0x03 - Issue Diagnostic Interrupt
-
- 0x04 - Quiesce [AMC only]
-
- 0x05-0xFF - Cold Reset
-
- activate <fru id>
-
Activate the specified FRU.
- deactivate <fru id>
-
Deactivate the specified FRU.
- policy get <fru id>
-
Get FRU activation policy.
- policy set <fru id>
<lockmask> < lock>
-
Set FRU activation policy. lockmask is 1 or 0 to indicate action on
the deactivation or activation locked bit respectively. lock is 1
or 0 to set/clear locked bit.
- portstate
set|getall|getgranted| getdenied
<parameters>
-
Get or set various port states. See usage for parameter details.
- power <chassis power command>
-
Shortcut to the chassis power commands. See the chassis power
commands for usage information.
- raw <netfn> <cmd>
[<data>]
-
This will allow you to execute raw IPMI commands. For example to query the
POH counter with a raw command:
> ipmitool -v raw 0x0 0xf
RAW REQ (netfn=0x0 cmd=0xf data_len=0)
RAW RSP (5 bytes)
3c 72 0c 00 00
- sdr
- get <id> ... [<id>]
-
Prints information for sensor data records specified by sensor id.
- info
-
This command will query the BMC for Sensor Data Record (SDR) Repository
information.
- type [<sensor type>]
-
This command will display all records from the SDR Repository of a specific
type. Run with type list (or simply with no type) to see the list
of available types. For example to query for all Temperature sensors:
> ipmitool sdr type Temperature
Baseboard Temp | 30h | ok | 7.1 | 28 degrees C
FntPnl Amb Temp | 32h | ok | 12.1 | 24 degrees C
Processor1 Temp | 98h | ok | 3.1 | 57 degrees C
Processor2 Temp | 99h | ok | 3.2 | 53 degrees C
- list | elist
[<all|full|compact|
event|mcloc|fru| generic>]
-
This command will read the Sensor Data Records (SDR) and extract sensor
information of a given type, then query each sensor and print its name,
reading, and status. If invoked as elist then it will also print
sensor number, entity id and instance, and asserted discrete states.
The default output will only display full and compact sensor
types, to see all sensors use the all type with this command.
- Valid types are:
- all
-
All SDR records (Sensor and Locator)
- full
-
Full Sensor Record
- compact
-
Compact Sensor Record
- event
-
Event-Only Sensor Record
- mcloc
-
Management Controller Locator Record
- fru
-
FRU Locator Record
- generic
-
Generic SDR records
- entity
<id>[.<instance>]
-
Displays all sensors associated with an entity. Get a list of valid entity
ids on the target system by issuing the sdr elist command. A list
of all entity ids can be found in the IPMI specifications.
- dump <file>
-
Dumps raw SDR data to a file. This data file can then be used as a local SDR
cache of the remote managed system with the -S <file> option
on the ipmitool command line. This can greatly improve performance over
system interface or remote LAN.
- fill sensors
-
Create the SDR Repository for the current configuration. Will perform a
'Clear SDR Repository' command so be careful.
- fill file <filename>
-
Fill the SDR Repository using records stored in a binary data file. Will
perform a 'Clear SDR Repository' command so be careful.
- sel
-
NOTE: System Event Log (SEL) entry-times are displayed as `Pre-Init
Time-stamp' if the SEL clock needs to be set. Ensure that the SEL clock is
accurate by invoking the sel time get and sel time set <time
string> commands.
- info
-
This command will query the BMC for information about the System Event Log
(SEL) and its contents.
- clear
-
This command will clear the contents of the SEL. It cannot be undone so be
careful.
- list | elist
-
When this command is invoked without arguments, the entire contents of the
System Event Log are displayed. If invoked as elist (extended list)
it will also use the Sensor Data Record entries to display the sensor ID
for the sensor that caused each event. Note this can take a long
time over the system interface.
- <count> | first
<count>
-
Displays the first count (least-recent) entries in the SEL. If
count is zero, all entries are displayed.
- last <count>
-
Displays the last count (most-recent) entries in the SEL. If
count is zero, all entries are displayed.
- delete <SEL Record ID> ... <SEL
Record ID>
-
Delete one or more SEL event records.
- add <filename ID>
-
Read event entries from a file and add them to the SEL. New SEL entries area
added onto the SEL after the last record in the SEL. Record added is of
type 2 and is automatically timestamped.
- get <SEL Record ID>
-
Print information on the specified SEL Record entry.
- save <file>
-
Save SEL records to a text file that can be fed back into the event
file ipmitool command. This can be useful for testing Event generation
by building an appropriate Platform Event Message file based on existing
events. Please see the available help for the 'event file ...' command for
a description of the format of this file.
- writeraw <file>
-
Save SEL records to a file in raw, binary format. This file can be fed back
to the sel readraw ipmitool command for viewing.
- readraw <file>
-
Read and display SEL records from a binary file. Such a file can be created
using the sel writeraw ipmitool command.
- time
- get
-
Displays the SEL clock's current time.
- set <time string>
-
Sets the SEL clock. Future SEL entries will use the time set by this
command. < time string> is of the form "MM/DD/YYYY
HH:MM:SS". Note that hours are in 24-hour form. It is recommended
that the SEL be cleared before setting the time.
- sensor
- list
-
Lists sensors and thresholds in a wide table format.
- get <id> ... [<id>]
-
Prints information for sensors specified by name.
- thresh <id> <threshold>
< setting>
-
This allows you to set a particular sensor threshold value. The sensor is
specified by name.
- Valid thresholds are:
-
unr Upper Non-Recoverable
ucr Upper Critical
unc Upper Non-Critical
lnc Lower Non-Critical
lcr Lower Critical
lnr Lower Non-Recoverable
- thresh <id> lower
<lnr> < lcr> <lnc>
-
This allows you to set all lower thresholds for a sensor at the same time.
The sensor is specified by name and the thresholds are listed in order of
Lower Non-Recoverable, Lower Critical, and Lower Non-Critical.
- thresh <id> upper
<unc> < ucr> <unr>
-
This allows you to set all upper thresholds for a sensor at the same time.
The sensor is specified by name and the thresholds are listed in order of
Upper Non-Critical, Upper Critical, and Upper Non-Recoverable.
- session
- info <active|all|id
0xnnnnnnnn| handle 0xnn>
-
Get information about the specified session(s). You may identify sessions by
their id, by their handle number, by their active status, or by using the
keyword `all' to specify all sessions.
- shell
This command will launch an interactive shell
which you can use to send multiple ipmitool commands to a BMC and see the
responses. This can be useful instead of running the full ipmitool command
each time. Some commands will make use of a Sensor Data Record cache and you
will see marked improvement in speed if these commands are able to reuse the
same cache in a shell session. LAN sessions will send a periodic keepalive
command to keep the IPMI session from timing out.
- sol
- info [<channel number>]
-
Retrieve information about the Serial-Over-LAN configuration on the
specified channel. If no channel is given, it will display SOL
configuration data for the currently used channel.
- payload <enable | disable |
status> < channel number> <userid>
-
Enable, disable or show status of SOL payload for the user on the specified
channel.
- set <parameter> <value>
[< channel>]
-
Configure parameters for Serial Over Lan. If no channel is given, it will
display SOL configuration data for the currently used channel.
Configuration parameter updates are automatically guarded with the updates
to the set-in-progress parameter.
- Valid parameters and values are:
-
- set-in-progress
- set-complete set-in-progress commit-write
- enabled
- true false
- force-encryption
- true false
- force-authentication
- true false
- privilege-level
- user operator admin oem
- character-accumulate-level
- Decimal number given in 5 milliseconds increments
- character-send-threshold
- Decimal number
- retry-count
- Decimal number. 0 indicates no retries after packet is
transmitted.
- retry-interval
- Decimal number in 10 millisend increments. 0 indicates that
retries should be sent back to back.
- non-volatile-bit-rate
- serial, 19.2, 38.4, 57.6, 115.2. Setting this value to
serial indicates that the BMC should use the setting used by the IPMI over
serial channel.
- volatile-bit-rate
- serial, 19.2, 38.4, 57.6, 115.2. Setting this value to
serial indiates that the BMC should use the setting used by the IPMI over
serial channel.
- activate [usesolkeepalive |
nokeepalive]
-
Causes ipmitool to enter Serial Over LAN mode, and is only available when
using the lanplus interface. An RMCP+ connection is made to the BMC, the
terminal is set to raw mode, and user input is sent to the serial console
on the remote server. On exit,the the SOL payload mode is deactivated and
the terminal is reset to its original settings.
Special escape sequences are provided to control the SOL session:
- ~. Terminate connection
- ~^Z Suspend ipmitool
- ~^X Suspend ipmitool, but don't restore tty on
restart
- ~B Send break
- ~~ Send the escape character by typing it twice
- ~? Print the supported escape sequences
Note that escapes are only recognized immediately after newline.
- deactivate
-
Deactivates Serial Over LAN mode on the BMC. Exiting Serial Over LAN mode
should automatically cause this command to be sent to the BMC, but in the
case of an unintentional exit from SOL mode, this command may be necessary
to reset the state of the BMC.
- spd <i2cbus> <i2caddr>
[< channel>] [<axread>]
-
This command may be used to read SPD (Serial Presence Detect) data using the
I2C Master Write-Read IPMI command.
- sunoem
- led
These commands provide a way to get and set the status of LEDs on a Sun
Microsystems server. Use 'sdr list generic' to get a list of devices that are
controllable LEDs. The
ledtype parameter is optional and not necessary
to provide on the command line unless it is required by hardware.
- get <sensorid>
[<ledtype>]
-
Get status of a particular LED described by a Generic Device Locator record
in the SDR. A sensorid of all will get the status of all available
LEDS.
- set <sensorid> <ledmode>
[< ledtype>]
-
Set status of a particular LED described by a Generic Device Locator record
in the SDR. A sensorid of all will set the status of all available
LEDS to the specified ledmode and ledtype.
- LED Mode is required for set operations:
-
OFF Off
ON Steady On
STANDBY 100ms on 2900ms off blink rate
SLOW 1HZ blink rate
FAST 4HZ blink rate
- LED Type is optional:
-
OK2RM Ok to Remove
SERVICE Service Required
ACT Activity
LOCATE Locate
- fan speed <0-100>
-
Set system fan speed (PWM duty cycle).
- sshkey
- set <userid>
<keyfile>
-
This command will allow you to specify an SSH key to use for a particular
user on the Service Processor. This key will be used for CLI logins to the
SP and not for IPMI sessions. View available users and their userids with
the 'user list' command.
- del <userid>
-
This command will delete the SSH key for a specified userid.
- tsol
This command allows Serial-over-LAN sessions to be established with Tyan
IPMIv1.5 SMDC such as the M3289 or M3290. The default command run with no
arguments will establish default SOL session back to local IP address.
Optional arguments may be supplied in any order.
- <ipaddr>
-
Send receiver IP address to SMDC which it will use to send serial traffic
to. By default this detects the local IP address and establishes two-way
session. Format of ipaddr is XX.XX.XX.XX
- port=NUM
-
Configure UDP port to receive serial traffic on. By default this is 6230.
- ro|rw
-
Confiure SOL session as read-only or read-write. Sessions are read-write by
default.
- user
- summary
-
Displays a summary of userid information, including maximum number of
userids, the number of enabled users, and the number of fixed names
defined.
- list
-
Displays a list of user information for all defined userids.
- set
- name <userid>
<username>
-
Sets the username associated with the given userid.
- password <userid>
[<password>]
-
Sets the password for the given userid. If no password is given, the
password is cleared (set to the NULL password). Be careful when removing
passwords from administrator-level accounts.
- disable <userid>
-
Disables access to the BMC by the given userid.
- enable <userid>
-
Enables access to the BMC by the given userid.
- priv <userid> <privilege
level> [< channel number>]
-
Set user privilege level on the specified channel. If the channel is not
specified, the current channel will be used.
- test <userid>
<16|20> [< password>]
-
Determine whether a password has been stored as 16 or 20 bytes.
OPEN INTERFACE¶
The ipmitool
open interface utilizes the OpenIPMI kernel device driver.
This driver is present in all modern 2.4 and all 2.6 kernels and it should be
present in recent Linux distribution kernels. There are also IPMI driver
kernel patches for different kernel versions available from the OpenIPMI
homepage.
The required kernel modules is different for 2.4 and 2.6 kernels. The following
kernel modules must be loaded on a 2.4-based kernel in order for ipmitool to
work:
- ipmi_msghandler
- Incoming and outgoing message handler for IPMI
interfaces.
- ipmi_kcs_drv
- An IPMI Keyboard Controler Style (KCS) interface driver for
the message handler.
- ipmi_devintf
- Linux character device interface for the message
handler.
The following kernel modules must be loaded on a 2.6-based kernel in order for
ipmitool to work:
- ipmi_msghandler
- Incoming and outgoing message handler for IPMI
interfaces.
- ipmi_si
- An IPMI system interface driver for the message handler.
This module supports various IPMI system interfaces such as KCS, BT, SMIC,
and even SMBus in 2.6 kernels.
- ipmi_devintf
- Linux character device interface for the message
handler.
Once the required modules are loaded there will be a dynamic character device
entry that must exist at
/dev/ipmi0. For systems that use devfs or udev
this will appear at
/dev/ipmi/0.
To create the device node first determine what dynamic major number it was
assigned by the kernel by looking in
/proc/devices and checking for the
ipmidev entry. Usually if this is the first dynamic device it will be
major number
254 and the minor number for the first system interface is
0 so you would create the device entry with:
mknod /dev/ipmi0 c 254 0
ipmitool includes some sample initialization scripts that can perform this task
automatically at start-up.
In order to have ipmitool use the OpenIPMI device interface you can specifiy it
on the command line:
ipmitool
-I open <
command>
BMC INTERFACE¶
The ipmitool bmc interface utilizes the
bmc device driver as provided by
Solaris 10 and higher. In order to force ipmitool to make use of this
interface you can specify it on the command line:
ipmitool
-I bmc <
command>
The following files are associated with the bmc driver:
- /platform/i86pc/kernel/drv/bmc
- 32-bit ELF kernel module for the bmc driver.
- /platform/i86pc/kernel/drv/amd64/bmc
- 64-bit ELF kernel module for the bmc driver.
- /dev/bmc
- Character device node used to communicate with the bmc
driver.
LIPMI INTERFACE¶
The ipmitool
lipmi interface uses the Solaris 9 IPMI kernel device
driver. It has been superceeded by the
bmc interface on Solaris 10. You
can tell ipmitool to use this interface by specifying it on the command line.
ipmitool
-I lipmi <
expression>
LAN INTERFACE¶
The ipmitool
lan interface communicates with the BMC over an Ethernet LAN
connection using UDP under IPv4. UDP datagrams are formatted to contain IPMI
request/response messages with a IPMI session headers and RMCP headers.
IPMI-over-LAN uses version 1 of the Remote Management Control Protocol (RMCP) to
support pre-OS and OS-absent management. RMCP is a request-response protocol
delivered using UDP datagrams to port 623.
The LAN interface is an authenticatiod multi-session connection; messages
delivered to the BMC can (and should) be authenticated with a
challenge/response protocol with either straight password/key or MD5
message-digest algorithm. ipmitool will attempt to connect with administrator
privilege level as this is required to perform chassis power functions.
You can tell ipmitool to use the lan interface with the
-I lan
option:
ipmitool
-I lan -H <
hostname> [
-U
<
username>] [
-P <
password>]
<
command>
A hostname must be given on the command line in order to use the lan interface
with ipmitool. The password field is optional; if you do not provide a
password on the command line, ipmitool will attempt to connect without
authentication. If you specify a password it will use MD5 authentication if
supported by the BMC and straight password/key otherwise, unless overridden
with a command line option.
LANPLUS INTERFACE¶
Like the
lan interface, the
lanplus interface communicates with
the BMC over an Ethernet LAN connection using UDP under IPv4. The difference
is that the
lanplus interface uses the RMCP+ protocol as described in
the IPMI v2.0 specification. RMCP+ allows for improved authentication and data
integrity checks, as well as encryption and the ability to carry multiple
types of payloads. Generic Serial Over LAN support requires RMCP+, so the
ipmitool
sol activate command requires the use of the
lanplus
interface.
RMCP+ session establishment uses a symmetric challenge-response protocol called
RAKP (
Remote Authenticated Key-Exchange Protocol) which allows the
negotiation of many options. ipmitool does not yet allow the user to specify
the value of every option, defaulting to the most obvious settings marked as
required in the v2.0 specification. Authentication and integrity HMACS are
produced with SHA1, and encryption is performed with AES-CBC-128. Role-level
logins are not yet supported.
ipmitool must be linked with the
OpenSSL library in order to perform the
encryption functions and support the
lanplus interface. If the required
packages are not found it will not be compiled in and supported.
You can tell ipmitool to use the lanplus interface with the
-I
lanplus option:
ipmitool
-I lanplus -H <
hostname> [
-U
<
username>] [
-P <
password>] <
command>
A hostname must be given on the command line in order to use the lan interface
with ipmitool. With the exception of the
-A and
-C options the
rest of the command line options are identical to those available for the
lan interface.
The
-C option allows you specify the authentication, integrity, and
encryption algorithms to use for for
lanplus session based on the
cipher suite ID found in the IPMIv2.0 specification in table 22-19. The
default cipher suite is
3 which specifies RAKP-HMAC-SHA1
authentication, HMAC-SHA1-96 integrity, and AES-CBC-128 encryption
algorightms.
FREE INTERFACE¶
The ipmitool
free interface utilizes the FreeIPMI libfreeipmi drivers.
You can tell ipmitool to use the FreeIPMI interface with the -I option:
ipmitool
-I free <
command>
IMB INTERFACE¶
The ipmitool
imb interface supports the Intel IMB (Intel Inter-module
Bus) Interface through the /dev/imb device.
You can tell ipmitool to use the IMB interface with the -I option:
ipmitool
-I imb <
command>
EXAMPLES¶
- Example 1: Listing remote sensors
-
> ipmitool -I lan -H 1.2.3.4 -f passfile sdr list
Baseboard 1.25V | 1.24 Volts | ok
Baseboard 2.5V | 2.49 Volts | ok
Baseboard 3.3V | 3.32 Volts | ok
- Example 2: Displaying status of a remote sensor
-
> ipmitool -I lan -H 1.2.3.4 -f passfile sensor get "Baseboard
1.25V"
Locating sensor record...
Sensor ID : Baseboard 1.25V (0x10)
Sensor Type (Analog) : Voltage
Sensor Reading : 1.245 (+/- 0.039) Volts
Status : ok
Lower Non-Recoverable : na
Lower Critical : 1.078
Lower Non-Critical : 1.107
Upper Non-Critical : 1.382
Upper Critical : 1.431
Upper Non-Recoverable : na
- Example 3: Displaying the power status of a remote
chassis
-
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power status
Chassis Power is on
- Example 4: Controlling the power on a remote
chassis
-
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power on
Chassis Power Control: Up/On
AUTHOR¶
Duncan Laurie <duncan@iceblink.org>
SEE ALSO¶
- IPMItool Homepage
- http://ipmitool.sourceforge.net
- Intelligent Platform Management Interface
Specification
- http://www.intel.com/design/servers/ipmi
- OpenIPMI Homepage
- http://openipmi.sourceforge.net
- FreeIPMI Homepage