NAME¶
DECLAR, GENPAT Package
ORIGIN¶
This software belongs to the ALLIANCE CAD SYSTEM developed by the ASIM team at
LIP6 laboratory of Université Pierre et Marie CURIE, in Paris,
France.
Web :
http://asim.lip6.fr/recherche/alliance/
E-mail :
alliance-users@asim.lip6.fr
SYNOPSYS¶
DECLAR("ident",":nb_space","format",mode,size,option);
PARAMETERS¶
- ident
- External connector, internal observing points or register's
name. For the hierarchical descriptions, the path-name of the internal
observing points or registers must be specified by the syntax :
instance1.instance11.name .
- nb_space
- Specify the number of blank space between each group of
value associated to the connectors, signals or registers in the output
file. 0,1,2,3,4,5,6,7,8,9 or nothing.
- format
- Specify the format that will be used to represent the value
associated to the connectors, signals or registers. X for Hexadecimal, O
for Octal and B for Binary.
- mode
- Specify the type of the connectors. IN for Input, OUT for
Output, INOUT for Input/Output, SIGNAL for internal observing point,
REGISTER for register. IN, OUT, INOUT, SIGNAL, REGISTER are constants
(defines) provided by genpat.
- size
- Specify the size of the bused connectors : empty
("") for the scalar connectors, "nb1" for the numbered
connectors, "nb1 TO nb2" or "(nb1 TO nb2)" (nb1 <
nb2), "nb1 DOWNTO nb2" or "(nb1 DOWNTO nb2)" (nb2 <
nb1) for the vectors. Where nb1 and nb2 are integer.
- option
- Specify options of the connector. "S" for a spied
connector, empty ("") for a normal connector.
DESCRIPTION¶
Describes a set of connectors, signals or registers of the same format, size and
mode.
EXAMPLE¶
DECLAR("a", ":2", "X", OUT, "3 DOWNTO 0", "S");
describes : a 3, a 2, a 1, a 0
format : Hexadecimal.
mode : Output.
option : Spied connector.
the group is separated of the others with 2 blank spaces.
result :
out a(3 downto 0) X spy ;;;
DECLAR ("toto", ":", "O", INOUT, "7 TO 11", "");
describes : toto 7, toto 8, toto 9, toto 10, toto 11.
format : Octal.
mode : Input/Output.
option : none.
the group is separated of the following with 0 blank space.
result :
inout toto(7 to 11) O ;
DECLAR ("ck", ":2", "B", IN, "", "");
describes : ck.
format : Binary.
mode : Input.
option : none.
the port is separated of the following with 2 blank spaces.
result :
in ck ;;;
DECLAR ("accu.f", ":", "B", SIGNAL, "", "S");
describes : accu.f .
format : Binary.
mode : Signal.
option : Spied connector.
the signal is separated of the following with 0 blank space.
result :
signal accu.f spy ;
DECLAR ("accu.reg", ":1", "B", REGISTER, "(3)", "");
describes : accu.reg .
format : Binary.
mode : Register.
option : none.
the signal is separated of the following with 1 blank space.
result :
register accu.reg(3) ;;;;
WARNING¶
The DECLAR function from the 4.0 release have a new parameter (option).
SEE ALSO¶
ARRAY(3),
genpat(1),
pat(5)
BUG REPORT¶
This tool is under development at the
ASIM department of the
LIP6
laboratory.
We need your feedback to improve documentation and tools.