NAME¶
lgagent - ION Load/Go remote agent program
SYNOPSIS¶
lgagent own_endpoint_ID
DESCRIPTION¶
ION Load/Go is a system for management of an ION-based network, enabling the
execution of ION administrative programs at remote nodes. The system comprises
two programs,
lgsend and
lgagent.
The
lgagent task on a given node opens the indicated ION endpoint for
bundle reception, receives the extracted payloads of Load/Go bundles sent to
it by
lgsend as run on one or more remote nodes, and processes those
payloads, which are the text of Load/Go source files.
Load/Go source file content is limited to newline-terminated lines of ASCII
characters. More specifically, the text of any Load/Go source file is a
sequence of
line sets of two types:
file capsules and
directives. Any Load/Go source file may contain any number of file
capsules and any number of directives, freely intermingled in any order, but
the typical structure of a Load/Go source file is simply a single file capsule
followed by a single directive.
When
lgagent identifies a file capsule, it copies all of the capsule's
text lines to a new file that it creates in the current working directory.
When
lgagent identifies a directive, it executes the directive by
passing the text of the directive to the
pseudoshell() function (see
platform(3)).
lgagent processes the line sets of a Load/Go
source file in the order in which they appear in the file, so the text of a
directive may reference a file that was created as the result of processing a
prior file capsule in the same source file.
EXIT STATUS¶
- "0"
- Load/Go remote agent processing has terminated.
FILES¶
lgfile contains the Load/Go file capsules and directives that are to be
processed.
ENVIRONMENT¶
No environment variables apply.
DIAGNOSTICS¶
The following diagnostics may be issued to the
ion.log log file:
- lgagent: can't attach to BP.
- Bundle Protocol is not running on this computer. Run bpadmin(1) to
start BP.
- lgagent: can't open own endpoint.
- own_endpoint_ID is not a declared endpoint on the local ION node.
Run bpadmin(1) to add it.
- lgagent: bundle reception failed.
- ION system problem. Investigate and correct before restarting.
- lgagent cannot continue.
- lgagent processing problem. See earlier diagnostic messages for details.
Investigate and correct before restarting.
- lgagent: no space for bundle content.
- ION system problem: have exhausted available SDR data store reserves.
- lgagent: can't receive bundle content.
- ION system problem: have exhausted available SDR data store reserves.
- lgagent: can't handle bundle delivery.
- ION system problem. Investigate and correct before restarting.
- lgagent: pseudoshell failed.
- Error in directive line, usually an attempt to execute a non-existent
administration program (e.g., a misspelled program name). Terminates
processing of source file content.
A variety of other diagnostics noting source file parsing problems may also be
reported. These errors are non-fatal but they terminate the processing of the
source file content from the most recently received bundle.
BUGS¶
Report bugs to <ion-bugs@korgano.eecs.ohiou.edu>
SEE ALSO¶
lgsend(1),