NAME¶
- scapin - Scan path insertion
-
ORIGIN¶
This software belongs to the ALLIANCE CAD SYSTEM developed by the ASIM team at
LIP6 laboratory of Université Pierre et Marie CURIE, in Paris,
France.
Web :
http://asim.lip6.fr/recherche/alliance/
E-mail :
alliance-users@asim.lip6.fr
SYNOPSIS¶
- scapin [-VRB] [-P file] Input_name Path_name Output_name
-
DESCRIPTION¶
SCAPIN is an automatic scan path generator for gate level netlists.
SCAPIN inserts a scan path in the netlist
Input_name and drives
a new netlist
Output_name. This scan path contains all registers
specified in the file
Path_name.path (see below for the exact syntax).
SCAPIN adds also 3 new connectors in the netlist: scan_in, scan_out and
scan_test in order to control the scan path. Eventually
SCAPIN adds an
output buffer before the output connector scan_out (option -B).
ENVIRONMENT VARIABLES¶
- MBK_WORK_LIB(1)
- indicates the path to the read/write directory for the session.
- MBK_IN_LO(1)
- indicates the input netlist file format.
- MBK_OUT_LO(1)
- indicates the output netlist file format.
- SCAPIN_PARAM_NAME
- indicates the location of a parameter file (with extention .scapin)
containing the properties (ports name, models name etc ...) of all cells
needed for the scan path insertion. (see below for the exact syntax)
OPTIONS¶
- -V
- Sets verbose mode on. Each step is displayed on the standard output.
- -R
- All registers of the scan path are replaced by an equivalent scannable
register cell (called reg-mux). (With the default option a simple
multiplexor is added just before all registers of the scan path).
- -B
- Adds an output buffer before the output connector scan_out.
- -P file
- Specifies a parameter file (with extention .scapin) containing the
properties of all cells needed for the scan path insertion. (see below for
the exact syntax)
# Example of .scapin file
BEGIN_MUX
MUX_MODEL mx2_x2
MUX_SEL cmd
MUX_INPUT_SEL i1
MUX_INPUT_NSEL i0
MUX_VDD vdd
MUX_VSS vss
MUX_OUTPUT q
END_MUX
BEGIN_REG
REG_MODEL sff1_x4
REG_CLK ck
REG_INPUT i
REG_VDD vdd
REG_VSS vss
REG_OUTPUT q
REG_MUX mx2_x2
REG_REG_MUX sff2_x4
END_REG
BEGIN_REG_MUX
REG_MUX_MODEL sff2_x4
REG_MUX_SEL cmd
REG_MUX_INPUT_SEL i1
REG_MUX_INPUT_NSEL i0
REG_MUX_CLK ck
REG_MUX_VDD vdd
REG_MUX_VSS vss
REG_MUX_OUTPUT q
REG_MUX_MUX mx2_x2
REG_MUX_REG sff1_x4
END_REG_MUX
BEGIN_BUF
BUF_MODEL buf_x2
BUF_INPUT i
BUF_VDD vdd
BUF_VSS vss
BUF_OUTPUT q
END_BUF
- Path_name
- Specifies a parameter file (with extention .path) containing an ordered
list of all instances (registers) of the scan path. It contains also the
name of the 3 connectors scan_in, scan_out and scan_test. (see below for
the exact syntax)
# Example of .path file
BEGIN_PATH_REG
cs_0
cs_1
cs_2
END_PATH_REG
BEGIN_CONNECTOR
SCAN_IN scin
SCAN_OUT scout
SCAN_TEST test
END_CONNECTOR
SEE ALSO¶
MBK_IN_LO(1).
MBK_OUT_LO(1).
MBK_WORK_LIB(1).
BUG REPORT¶
This tool is under development at the
ASIM department of the
LIP6
laboratory.
We need your feedback to improve documentation and tools.