Scroll to navigation

opareport(8) Master map: IFSFFCLIRG (Man Page) opareport(8)

NAME

opareport

(All) Provides powerful fabric analysis and reporting capabilities. Must be run on a host connected to the Intel(R) Omni-Path Fabric with the Intel(R) Omni-Path Fabric Suite FastFabric Toolset installed.

Syntax

opareport [-v][-q] [-h hfi] [-p port] [--timeout] [-o report]
[-d detail] [-P|-H] [-N] [-x] [-X snapshot_input] [-T topology_input] [-s]
[-r] [-V] [-i seconds] [-b date_time] [-e date_time] [-C] [-a] [-m]
[-M] [-A] [-c file] [-L] [-F point] [-S point] [-D point] [-Q]

Options

--help
Produces full help text.

-v/--verbose
Returns verbose output.

-q/--quiet
Disables progress reports.

-h/--hfi hfi
Specifies the HFI, numbered 1..n. Using 0 specifies that the -p port port is a system-wide port number. Default is 0.

-p/--port port
Specifies the port, numbered 1..n. Using 0 specifies the first active port. Default is 0.

--timeout
Specifies the timeout (wait time for response) in ms. Default is 1000 ms.

-o/--output report
Specifies the report type for output. Refer to Report Types for details.

-d/--detail level
Specifies the level of detail 0-n for output. Default is 2.

-P/--persist
Only includes data persistent across reboots.

-H/--hard
Only includes permanent hardware data.

-N/--noname
Omits node and IOC names.

-x/--xml
Produces output in XML.

-X/--infile snapshot_input
Generates a report using the data in the snapshot_input file. snapshot_input must have been generated during a previous -o snapshot run. When used, the -s, -i, -C, and -a options are ignored. '-' may be used as the snapshot_input to specify stdin.

-T/--topology topology_input
Uses topology_input file to augment and verify fabric information. When used, various reports can be augmented with information not available electronically (such as cable labels). '-' may be used to specify stdin.

-s/--stats
Gets performance statistics for all ports.

-i/--interval seconds
Obtains performance statistics over interval seconds. Clears all statistics, waits interval seconds, then generates report. Implies -s option.

-b/--begin date_time
Obtains past performance stats over an interval beginning at date_time. Implies -s option. date_time may be a time entered as HH:MM[:SS] or date as mm/dd/YYYY, dd.mm.YYYY, YYYY-mm-dd or date followed by time; for example, "2016-07-04 14:40". Relative times are taken as "x [second|minute|hour|day](s) ago.

-e/--end date_time
Obtains past performance stats over an interval ending at date_time. Implies -s option.

date_time may be a time entered as HH:MM[:SS] or date as mm/dd/YYYY, dd.mm.YYYY, YYYY-mm-dd or date followed by time; for example, "2016-07-04 14:40". Relative times are taken as "x [second|minute|hour|day](s) ago.
-C/--clear
Clears performance statistics for all ports. Only statistics with error thresholds are cleared. A clear occurs after generating the report.

-a/--clearall
Clears all performance statistics for all ports.

-m/--smadirect
Accesses fabric information directly from SMA.

-M/--pmadirect
Accesses performance statistics using direct PMA.

-A/--allports
Gets PortInfo for down switch ports. Uses direct SMA to get this data. If used with -M, also gets PMA stats for down switch ports.

-c/--config file
Specifies the error thresholds configuration file. Default is /etc/opa/opamon.conf file.

-L/--limit
Limits operation to exact specified focus with -F for port error counters check (-o errors) and port counters clear (-C or -i). Normally, the neighbor of each selected port is also checked/cleared. Does not affect other reports.

-F/--focus point
Specifies the focus area for report.

Limits output to reflect a subsection of the fabric. May not work with all reports. (For example, route, mcgroups, and the verify* reports may ignore the option or not generate useful results.)
-S/--src point
Specifies the source for trace route. Default is local port.

-D/--dest point
Specifies the destination for trace route.

-Q/--quietfocus
Excludes focus description from report.

-h and -p options permit a variety of selections:

-h 0
First active port in system (Default).

-h 0 -p 0
First active port in system.

-h x
First active port on HFI x.

-h x -p 0
First active port on HFI x.

-h 0 -p y
Port y within system (no matter which ports are active).

-h x -p y
HFI x, port y.

Snapshot-Specific Options

-r/--routes
Gets routing tables for all switches.

-V/--vltables
Gets the P-Key tables for all nodes and the QoS VL-related tables for all ports.

Report Types

comps
Summary of all systems and SMs in fabric.

brcomps
Brief summary of all systems and SMs in fabric.

nodes
Summary of all node types and SMs in fabric.

brnodes
Brief summary of all node types and SMs in fabric.

ious
Summary of all IO units in the fabric.

lids
Summary of all LIDs in the fabric.

links
Summary of all links.

extlinks
Summary of links external to systems.

filinks
Summary of links to FIs.

islinks
Summary of inter-switch links.

extislinks
Summary of inter-switch links external to systems.

slowlinks
Summary of links running slower than expected.

slowconfiglinks
Summary of links configured to run slower than supported, includes slowlinks.

slowconnlinks
Summary of links connected with mismatched speed potential, includes slowconfiglinks.

misconfiglinks
Summary of links configured to run slower than supported.

misconnlinks
Summary of links connected with mismatched speed potential.

errors
Summary of links whose errors exceed counts in the configuration file.

otherports
Summary of ports not connected to the fabric.

linear
Summary of linear forwarding data base (FDB) for each switch.

mcast
Summary of multicast FDB for each switch in the fabric.

mcgroups
Summary of multicast groups.

When used in conjunction with -d, the following report details are possible:

  • -d0 : Shows the number of multicast groups
  • -d1 : Shows a list of multicast groups
  • -d2 : Shows a list of members per multicast group

This report can be used with option -X.
portusage
Summary of ports referenced in linear FDB for each switch, broken down by NodeType of DLID.

pathusage
Summary of number of FI to FI paths routed through each switch port.

treepathusage
Analysis of number of FI to FI paths routed through each switch port for a FAT tree.

portgroups
Summary of adaptive routing port groups for each switch.

quarantinednodes
Summary of quarantined nodes.

validateroutes
Validates all routes in the fabric.

validatevlroutes
Validates all routes in the fabric using SLSC, SCSC, and SCVL tables.

validatepgs
Validates all port groups in the fabric.

validatecreditloops
Validates topology configuration of the fabric to identify any existing credit loops.

validatevlcreditloops
Validates topology configuration of the fabric including SLSC, SCSC, and SCVL tables to identify any existing credit loops.

validatemcroutes
Validates multicast routes of the fabric to identify loops in multicast forwarding tables and detect MFT-multicast membership inconsistencies.

vfinfo
Summary of virtual fabric (vFabric) information.

vfmember
Summary of vFabric membership information.

dgmember
Summary of DeviceGroup membership information.

verifyfis
Compares fabric (or snapshot) FIs to supplied topology and identifies differences and omissions.

verifysws
Compares fabric (or snapshot) switches to supplied topology and identifies differences and omissions.

verifynodes
Returns verifyfis and verifysws reports.

verifysms
Compares fabric (or snapshot) SMs to supplied topology and identifies differences and omissions.

verifylinks
Compares fabric (or snapshot) links to supplied topology and identifies differences and omissions.

verifyextlinks
Compares fabric (or snapshot) links to supplied topology and identifies differences and omissions. Limits analysis to links external to systems.

verifyfilinks
Compares fabric (or snapshot) links to supplied topology and identify differences and omissions. Limits analysis to links to FIs.

verifyislinks
Compares fabric (or snapshot) links to supplied topology and identify differences and omissions. Limits analysis to inter-switch links.

verifyextislinks
Compares fabric (or snapshot) links to supplied topology and identify differences and omissions. Limits analysis to inter-switch links external to systems.

verifyall
Returns verifyfis, verifysws, verifysms, and verifylinks reports.

all
Returns comps, nodes, ious, links, extlinks, slowconnlinks, and errors reports.

route
Traces route between -S and -D points.

bfrctrl
Reports Buffer Control Tables for all ports.

snapshot
Outputs snapshot of the fabric state for later use as snapshot_input. This implies -x. May not be combined with other reports. When selected, -F, -P, -H, and -N options are ignored.

topology
Outputs the topology of the fabric for later use as topology_input. This implies -x. May not be combined with other reports. Use with detail level 3 or more to get Port element under Node in output xml.

none
No report, useful to clear statistics.

Point Syntax

gid:value
value is numeric port GID of form: subnet:guid.

lid:value
value is numeric LID.

lid:value:node
value is numeric LID, selects entire node with given LID.

lid:value:port:value2
value is numeric LID of node, value2 is port number.

portguid:value
value is numeric port GUID.

nodeguid:value
value is numeric node GUID.

nodeguid:value1:port:value2
value1 is numeric node GUID, value2 is port number.

iocguid:value
value is numeric IOC GUID.

iocguid:value1:port:value2
value1 is numeric IOC GUID, value2 is port number.

systemguid:value
value is numeric system image GUID.

systemguid:value1:port:value2
value1 is the numeric system image GUID, value2 is port number.

ioc:value
value is IOC Profile ID String (IOC Name).

ioc:value1:port:value2
value1 is IOC Profile ID String (IOC Name), value2 is port number.

iocpat:value
value is glob pattern for IOC Profile ID String (IOC Name).

iocpat:value1:port:value2
value1 is glob pattern for IOC Profile ID String (IOC Name), value2 is port number.

ioctype:value
value is IOC type (SRP or OTHER).

ioctype:value1:port:value2
value1 is IOC type (SRP or OTHER); value2 is port number.

node:value
value is node description (node name).

node:value1:port:value2
value1 is node description (node name), value2 is port number.

nodepat:value
value is glob pattern for node description (node name).

nodepat:value1:port:value2
value1 is the glob pattern for the node description (node name), value2 is port number.

nodedetpat:value
value is glob pattern for node details.

nodedetpat:value1:port:value2
value1 is the glob pattern for the node details, value2 is port number.

nodetype:value
value is node type (SW, FI, or RT).

nodetype:value1:port:value2
value1 is node type (SW, FI, or RT), value2 is port number.

rate:value
value is string for rate (25g, 50g, 75g, 100g), omits switch mgmt port 0.

portstate:value
value is a string for state (down, init, armed, active, notactive, initarmed).

portphysstate:value
value is a string for PHYs state (polling, disabled, training, linkup, recovery, offline, test)

mtucap:value
value is MTU size (2048, 4096, 8192, 10240), omits switch mgmt port 0.

labelpat:value
value is glob pattern for cable label.

lengthpat:value
value is glob pattern for cable length.

cabledetpat:value
value is glob pattern for cable details.

cabinflenpat:value
value is glob pattern for cable info length.

cabinfvendnamepat:value
value is glob pattern for cable info vendor name.

cabinfvendpnpat:value
value is glob pattern for cable info vendor part number.

cabinfvendrevpat:value
value is glob pattern for cable info vendor revision.

cabinfvendsnpat:value
value is glob pattern for cable info vendor serial number.

cabinftype:value
value is either optical, passive_copper, active_copper, or unknown.

linkdetpat:value
value is glob pattern for link details.

portdetpat:value
value is glob pattern for port details.

sm
Specifies the master subnet manager (SM).

smdetpat:value
value is glob pattern for SM details.

route:point1:point2
Specifies all ports along the routes between the two given points.

led:value
value is either on or off for LED port beacon.

linkqual:value
Specifies the ports with a link quality equal to value.

linkqualLE:value
Specifies the ports with a link quality less than or equal to value.

linkqualGE:value
Specifies the ports with a link quality greater than or equal to value.

Examples

opareport can generate hundreds of different reports. Commonly generated reports include the following:

opareport -o comps -d 3
opareport -o errors -o slowlinks
opareport -o nodes -F portguid:0x00117500a000447b
opareport -o nodes -F nodeguid:0x001175009800447b:port:1
opareport -o nodes -F nodeguid:0x001175009800447b
opareport -o nodes -F 'node:duster hfi1_0'
opareport -o nodes -F 'node:duster hfi1_0:port:1'
opareport -o nodes -F 'nodepat:d*'
opareport -o nodes -F 'nodepat:d*:port:1'
opareport -o nodes -F 'nodedetpat:compute*'
opareport -o nodes -F 'nodedetpat:compute*:port:1'
opareport -o nodes -F nodetype:FI
opareport -o nodes -F nodetype:FI:port:1
opareport -o nodes -F lid:1
opareport -o nodes -F led:on opareport -o nodes -F led:off opareport -o nodes -F lid:1:node
opareport -o nodes -F lid:1:port:2
opareport -o nodes -F gid:0xfe80000000000000:0x00117500a000447b
opareport -o nodes -F systemguid:0x001175009800447b
opareport -o nodes -F systemguid:0x001175009800447b:port:1
opareport -o nodes -F iocguid:0x00117501300001e0
opareport -o nodes -F iocguid:0x00117501300001e0:port:2
opareport -o nodes -F 'ioc:Chassis 0x001175005000010C, Slot 2, IOC 1'
opareport -o nodes -F 'ioc:Chassis 0x001175005000010C, Slot 2, IOC 1:port:2'
opareport -o nodes -F 'iocpat:*Slot 2*'
opareport -o nodes -F 'iocpat:*Slot 2*:port:2'
opareport -o nodes -F ioctype:SRP opareport -o nodes -F ioctype:SRP:port:2
opareport -o extlinks -F rate:100g
opareport -o extlinks -F portstate:armed
opareport -o extlinks -F portphysstate:linkup
opareport -o extlinks -F 'labelpat:S1345*'
opareport -o extlinks -F 'lengthpat:11m'
opareport -o extlinks -F 'cabledetpat:*hitachi*'
opareport -o extlinks -F 'linkdetpat:*core ISL*'
opareport -o extlinks -F 'portdetpat:*mgmt*'
opareport -o links -F mtucap:2048
opareport -o nodes -F sm
opareport -o nodes -F 'smdetpat:primary*'
opareport -o nodes -F 'route:node:duster hfi1_0:node:cuda hfi1_0'
opareport -o nodes -F 'route:node:duster hfi1_0:port:1:node:cuda hfi1_0:port:2'
opareport -s -o snapshot > file
opareport -o topology > topology.xml
opareport -o errors -X file
opareport -s --begin "2 days ago"
opareport -s --begin "12:30" --end "14:00"

Other Information

opareport also supports operation with the Fabric Manager Performance Manager (PM)/Performance Manager Agent (PMA). When opareport detects the presence of a PM, it automatically issues any required PortCounter queries and clears to the PM to access the PMs running totals. If a PM is not detected, then opareport directly accesses the PMAs on all the nodes. The -M option can force access to the PMA even if a PM is present.

opareport takes advantage of these interfaces to obtain extensive information about the fabric from the subnet manager and the end nodes. Using this information, opareport is able to cross-reference it and produce analysis greatly beyond what any single subnet manager request could provide. As such, it exceeds the capabilities previously available in tools such as opasaquery and opafabricinfo.

opareport obtains and displays counters from the Fabric Manager PM/PA or directly from the fabric PMAs using the -M option.

opareport internally cross-references all this information so its output can be in user-friendly form. Reports include GUIDs, LIDs, and names for components. Obviously, these reports are easiest to read if the end user has taken the time to provide unique names for all the components in the fabric (node names and IOC names). All Intel components support this capability. For hosts, the node names are automatically assigned based on the network host name of the server. For switches and line cards, the names can be assigned using the element managers for each component.

Each run of opareport obtains up-to-date information from the fabric. At the start of the run opareport takes a few seconds to obtain all the fabric data, then it is output to stdout. The reports are sorted by GUIDs and other permanent information so they can be rerun in the future and produce output in the same order even if components have been rebooted. This is useful for comparison using simple tools like diff. opareport permits multiple reports to be requested for a single run (for example, one of each report type).

By default, opareport uses the first active port on the local system. However, if the Management Node is connected to more than one fabric (for example, a subnet), the Intel(R) Omni-Path Host Fabric Interface (HFI) and port may be specified to select the fabric to analyze.

Intel Corporation Copyright(C) 2015-2018