table of contents
SOLIS(8) | NUT Manual | SOLIS(8) |
NAME¶
solis - Driver for Brazilian Microsol SOLIS UPS equipmentNOTE¶
This man page only documents the hardware-specific features of the solis driver. For information about the core driver, see nutupsdrv(8).SUPPORTED HARDWARE¶
This driver has been tested with :•Solis 1000 VA
•Solis 1500 VA
•Solis 2000 VA
•Solis 3000 VA
•Back-UPS BZ1200-BR
•Back-UPS BZ2200BI-BR
All Solis models are sinusoidal on-line.
In 2009, Schneider Electric acquired Microsol Technologies, and by 2012, the entire Microsol line of equipment was being sold under the APC brand.
EXTRA ARGUMENTS¶
This driver support the following extra optional settings in the ups.conf(5).battext = n - (default = 0, no extra battery, where n = Ampere*hour )
prgshut = 1 - (default = 0, no programable shutdown )
COMMANDS¶
•shutdown.return - Shut down in .3 minutes and
restart in .3 minutes
•shutdown.stayoff - Shut down in .3 minutes and do
not return
ISSUES¶
The APC version of the Microsol protocol is slightly incompatible with the solis driver. As of version 0.62 of the solis driver, the driver will connect to the UPS, but some values are read incorrectly.AUTHOR¶
Silvino B. Magalhães <sbm2yk@gmail.com>SEE ALSO¶
The core driver:¶
nutupsdrv(8)Internet resources:¶
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/12/29/2015 | Network UPS Tools 2.7.3. |