NAME¶
- EDS
- - Embedded Data Systems Sensors
- EDS0064
- Temperature
- EDS0065
- Temperature and Humidity
- EDS0066
- Temperature and Barometric Pressure
- EDS0067
- Temperature and Light
- EDS0068
- Temperature, Barometric Pressure and Light
- EDS0070
- Vibration
- EDS0071
- RTD 4-wire temperature
- EDS0072
- RTD 3-wire temperature
- EDS0080
- 8 Channel Analog Current Input
- EDS0082
- 8 Channel Analog Voltage Input
- EDS0083
- 4 Channel Analog Current Input
- EDS0085
- 4 Channel Analog Voltage Input
- EDS0090
- 8 Discrete I/O
SYNOPSIS¶
Embedded Data Systems microprocessor-based sensors
Sub-type ( all )¶
7E [.]XXXXXXXXXXXX[XX][/[
device_id |
device_type |
tag ]]
Memory ( all )¶
7E [.]XXXXXXXXXXXX[XX][/[
memory |
pages/page.[0-2|ALL] ]]
Standard ( all )¶
7E [.]XXXXXXXXXXXX[XX][/[
address |
crc8 |
id |
locator |
r_address |
r_id |
r_locator |
type ]]
Temperature ( EDS0064/5/6/7/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[
temperature |
counters/seconds
|
alarm/temp_[hi|low] |
alarm/clear |
set_alarm/temp_[hi|low] |
threshold/temp_[hi|low] ]]
Humidity ( EDS0065/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[
humidity |
humidex |
dew_point |
heat_index |
alarm/humidity_[hi|low] |
alarm/humidex_[hi|low] |
alarm/dew_point_[hi|low] |
alarm/heat_index_[hi|low] |
alarm/clear |
set_alarm/humidity_[hi|low] |
set_alarm/humidex_[hi|low] |
set_alarm/dew_point_[hi|low] |
set_alarm/heat_index_[hi|low] |
threshold/humidity_[hi|low] |
threshold/humidex_[hi|low] |
threshold/dew_point_[hi|low] |
threshold/heat_index_[hi|low] ]]
Barometric Pressure ( EDS0066/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[
pressure |
inHg |
alarm/pressure_[hi|low] |
alarm/inHg_[hi|low] |
alarm/clear |
set_alarm/pressure_[hi|low] |
set_alarm/inHg_[hi|low] |
threshold/pressure_[hi|low] |
threshold/inHg_[hi|low] ]]
Light ( EDS0067/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[
light |
alarm/light_[hi|low] |
alarm/clear |
set_alarm/light_[hi|low] |
threshold/light_[hi|low] ]]
Vibration ( EDS0070 )¶
7E.XXXXXXXXXXXX/EDS0070 [/[
vib_level |
vib_peak |
vib_min |
vib_max |
counter/seconds |
alarm/vib_[hi|low] |
alarm/clear |
set_alarm/vib_[hi|low]
|
threshold/vib_[hi|low] ]]
RTD Temperature ( EDS0071/2 )¶
7E.XXXXXXXXXXXX/EDS007X [/[
temperature |
resistance |
raw |
delay |
user_byte |
calibration/[key|constant] |
counter/[seconds|samples] |
alarm/temp_[hi|low] |
alarm/RTD_[hi_low] |
alarm/clear |
set_alarm/temp_[hi|low] |
set_alarm/RTD_[hi_low] |
threshold/temp_[hi|low] |
threshold/RTD_[hi_low] ]]
Analog Current ( EDS0080 [0-7] EDS0083 [0-3] )¶
7E.XXXXXXXXXXXX/EDS0080 [/[
current.[0-7|ALL] |
max_current.[0-7|ALL] |
min_current.[0-7|ALL] |
threshold/current_hi.[0-7|ALL] |
threshold/current_low.[0-7|ALL]
|
alarm/current_hi.[0-7|ALL|BYTE] |
alarm/current_low.[0-7|ALL|BYTE] |
set_alarm/current_hi.[0-7|ALL|BYTE] |
set_alarm/current_low.[0-7|ALL|BYTE] |
counter/seconds |
memory |
pages/page.[0-4|ALL]
Analog Voltage ( EDS0082 [0-7] EDS0085 [0-3] )¶
7E.XXXXXXXXXXXX/EDS0082 [/[
volts.[0-7|ALL] |
max_volts.[0-7|ALL] |
min_volts.[0-7|ALL] |
threshold/volts_hi.[0-7|ALL] |
threshold/volts_low.[0-7|ALL] |
alarm/volts_hi.[0-7|ALL|BYTE] |
alarm/volts_low.[0-7|ALL|BYTE] |
set_alarm/volts_hi.[0-7|ALL|BYTE] |
set_alarm/volts_low.[0-7|ALL|BYTE] |
counter/seconds |
memory |
pages/page.[0-4|ALL]
I/O ( EDS0090 )¶
7E.XXXXXXXXXXXX/EDS009X [/[
input.[0-7|ALL] |
counter/[seconds
| pulses.[0-7|ALL]|reset.[0-7|ALL|BYTE]] |
output/[set.[0-7|ALL|BYTE]|off.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] |
latch/[state.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] |
alarm/[hi.[0-7|ALL]|low.[0-7|ALL]|clear] |
set_alarm/[hi.[0-7|ALL]|low.[0-7|ALL]]
LED ( all )¶
7E.XXXXXXXXXXXX/EDS00XX/LED/[state|control]
relay ( all )¶
7E.XXXXXXXXXXXX/EDS00XX/relay/[state|control]
FAMILY CODE¶
- 7E
TEMPERATURE¶
EDS006X/temperature¶
read-only, floating-point
Temperature for the EDS006X series of chips. In the -55C to 125C range, with
0.0636C precision. The temperature is read every second, continually. Data is
presented in the specified temperature scale, Celsius by default.
EDS007X/temperature¶
read-only, floating-point
Temperature for the EDS007X series of chips. Read using a wide-range precise RTD
sensor. Typical range is -60C to 260C with 0.15C accuracy, although a range of
-200C to 850C is possible. The temperature is read every second unless a
longer
EDS007X/delay is given. Data is presented in the specified
temperature scale, Celsius by default.
EDS007X/resistance¶
read-only, floating-point
Actual measured resistance (Ohms) of the RTD element. Useful if the RTD element
doesn't conform to the typical European IEC 60751 standard.
HUMIDITY¶
EDS006X/humidity¶
read-only, floating-point
Relative humidity in the 0-100 range (percent). Read every 0.2 seconds.
EDS006X/dew_point¶
read-only, floating-point
Dew point computed from
EDS006X/temperature and
EDS006X/humidity
computered every 0.2 seconds. Data is a calculated temperature and is reported
in the specified temperature scale. Default Celsius.
EDS006X/heat_index¶
read-only, floating-point
Heat index computed from
EDS006X/temperature and
EDS006X/humidity
computered every 0.2 seconds. Data is a calculated temperature and is reported
in the specified temperature scale. Default Celsius.
EDS006X/humidex¶
read-only, floating-point
Humidex (popular in Canada) computed from
EDS006X/temperature and
EDS006X/humidity computed every 0.2 seconds. Data is a percent and
reported in the 0-100 range.
LIGHT¶
EDS006X/light¶
read-only, unsigned integer
Ambient light in Lux. Measured every 0.2 seconds.
PRESSURE¶
EDS006X/pressure¶
read-only, floating-point
Ambient pressure, measured every 0.2 seconds. Data in the selected pressure
scale (default mBar).
EDS006X/inHg¶
read-only, floating-point
Ambient pressure, measured every 0.2 seconds. Data in the inHg scale.
VIBRATION¶
EDS0070/vib_level¶
read_only, unsigned integer
Vibration registered by sensor (instantaneous value) in 0-1023 range.
EDS0070/vib_peak¶
read_only, unsigned integer
Vibration registered by sensor (highest recent value -- slowly decays) in 0-1023
range.
EDS0070/vib_min¶
read_only, unsigned integer
Vibration registered by sensor (lowest value) in 0-1023 range.
EDS0070/vib_max¶
read_only, unsigned integer
Vibration registered by sensor (highest value) in 0-1023 range.
CURRENT¶
The
EDS0080 and
EDS0083 measure current in the 4-20mA range, with
upper and threshold limits and the ability to set an alarm and independently
trigger a relay if the value is out of range.
EDS0080/current.[0-7|ALL] EDS0083/current.[0-3|ALL]¶
read-only, floating point
Current current level. (4-20mA)
EDS0080/max_current.[0-7|ALL] EDS0080/max_current.[0-3|ALL]¶
EDS0083/min_current.[0-7|ALL] EDS0083/min_current.[0-3|ALL]¶
read-only, floating point
Maximum and minimum current readings since last
alarm/clear command.
VOLTAGE¶
The
EDS0082 and
EDS0085 measure voltage in the 0-10V range, with
upper and threshold limits and the ability to set an alarm and independently
trigger a relay if the value is out of range.
EDS0082/volts.[0-7|ALL] EDS0085/volts.[0-3|ALL]¶
read-only, floating point
Current voltage level. (0-10V)
EDS0082/max_volts.[0-7|ALL] EDS0085/max_volts.[0-3|ALL]¶
EDS0082/min_volts.[0-7|ALL] EDS0085/min_volts.[0-3|ALL]¶
read-only, floating point
Maximum and minimum voltage readings since last
alarm/clear command.
THRESHOLD¶
High and low range of acceptable sensor readings. Values outside this range will
trigger an alarm if the corresponding
EDS00XX/set_alarm flag is set.
EDS00XX/threshold/temp_hi EDS00XX/threshold/temp_low¶
read-write, floating-point
Threshold temperatures in the specified temperature scale. Default Celsius.
EDS006X/threshold/humidity_hi EDS006X/threshold/humidity_low¶
EDS006X/threshold/dew_point_hi EDS006X/threshold/dew_point_low¶
EDS006X/threshold/heat_index_hi EDS006X/threshold/heat_index_low¶
EDS006X/threshold/humidex_hi EDS006X/threshold/humidex_low¶
read-write, floating-point
Threshold humidity values.
Dew point and
Heat index are in the
specified temperature scale. Default Celsius.
EDS006X/threshold/pressure_hi EDS006X/threshold/pressure_low¶
EDS006X/threshold/inHg_hi EDS006X/threshold/inHg_low¶
read-write, floating-point
Threshold barometric pressure values.
Pressure is the specified pressure
scale. Default mBar.
EDS006X/threshold/light_hi EDS006X/threshold/light_low¶
read-write, unsigned
Threshold light (lux) values.
EDS0070/threshold/vib_hi EDS0070/threshold/vib_low¶
read-write, unsigned
Vibration sensor alarm limits in 0-1023 range.
EDS007X/threshold/resistance_hi EDS007X/threshold/resistance_low¶
read-write, floating-point
Threshold RTD resistance values (Ohm).
EDS0080/threshold/current_hi.[0-7|ALL]¶
EDS0080/threshold/current_low.[0-7|ALL]¶
EDS0082/threshold/volts_hi.[0-7|ALL]¶
EDS0082/threshold/volts_low.[0-7|ALL]¶
EDS0083/threshold/current_hi.[0-3|ALL]¶
EDS0083/threshold/current_low.[0-3|ALL]¶
EDS0085/threshold/volts_hi.[0-3|ALL]¶
EDS0085/threshold/volts_low.[0-3|ALL|]¶
read-write, floating-point
Voltage or current threshold limits
SET ALARM¶
Set conditional alarm to trigger if corresponding flag is set. Also must set
high and low
threshold.
EDS00XX/set_alarm/temp_hi EDS00XX/set_alarm/temp_low¶
EDS006X/set_alarm/humidity_hi EDS006X/set_alarm/humidity_low¶
EDS006X/set_alarm/dew_point_hi EDS006X/set_alarm/dew_point_low¶
EDS006X/set_alarm/heat_index_hi EDS006X/set_alarm/heat_index_low¶
EDS006X/set_alarm/humidex_hi EDS006X/set_alarm/humidex_low¶
EDS006X/set_alarm/pressure_hi EDS006X/set_alarm/pressure_low¶
EDS006X/set_alarm/inHg_hi EDS006X/set_alarm/inHg_low¶
EDS006X/set_alarm/light_hi EDS006X/set_alarm/light_low¶
EDS0070/set_alarm/vib_hi EDS0070/set_alarm/vib_low¶
EDS007X/set_alarm/resistance_hi EDS007X/set_alarm/resistance_low¶
EDS0080/set_alarm/current_hi.[0-7|ALL|BYTE]¶
EDS0080/set_alarm/current_low.[0-7|ALL|BYTE]¶
EDS0082/set_alarm/volts_hi.[0-7|ALL|BYTE]¶
EDS0082/set_alarm/volts_low.[0-7|ALL|BYTE]¶
EDS0083/set_alarm/current_hi.[0-3|ALL|BYTE]¶
EDS0083/set_alarm/current_low.[0-3|ALL|BYTE]¶
EDS0085/set_alarm/volts_hi.[0-3|ALL|BYTE]¶
EDS0085/set_alarm/volts_low.[0-3|ALL|BYTE]¶
read-write, yes-no
Flag to set corresponding out-of-range alarm. "1" turns on flag, and
"0" turns off.
ALARM¶
Show or clear the out-of-range flags. When set, the device will respond to a
conditional search. Clearing the flags is performed with the
EDS00XX/alarm/clear command, not just having the measured value return
to the center range.
EDS00XX/alarm/clear¶
write-only, yes-no
Write "1" to clear
ALL the alarm flags.
EDS00XX/alarm/temp_hi EDS00XX/alarm/temp_low¶
EDS006X/alarm/humidity_hi EDS006X/alarm/humidity_low¶
EDS006X/alarm/dew_point_hi EDS006X/alarm/dew_point_low¶
EDS006X/alarm/heat_index_hi EDS006X/alarm/heat_index_low¶
EDS006X/alarm/humidex_hi EDS006X/alarm/humidex_low¶
EDS006X/alarm/pressure_hi EDS006X/alarm/pressure_low¶
EDS006X/alarm/inHg_hi EDS006X/alarm/inHg_low¶
EDS006X/alarm/light_hi EDS006X/alarm/light_low¶
EDS0070/alarm/vib_hi EDS007X/alarm/vib_low¶
EDS007X/alarm/resistance_hi EDS007X/alarm/resistance_low¶
EDS0080/alarm/current_hi.[0-7|ALL|BYTE]¶
EDS0080/alarm/current_low.[0-7|ALL|BYTE]¶
EDS0082/alarm/volts_hi.[0-7|ALL|BYTE]¶
EDS0082/alarm/volts_low.[0-7|ALL|BYTE]¶
EDS0083/alarm/current_hi.[0-3|ALL|BYTE]¶
EDS0083/alarm/current_low.[0-3|ALL|BYTE]¶
EDS0085/alarm/volts_hi.[0-3|ALL|BYTE]¶
EDS0085/alarm/volts_low.[0-3|ALL|BYTE]¶
EDS0090/alarm/hi[0-7|ALL] EDS0090/alarm/low[0-7|ALL]¶
read-only, yes-no
Show corresponding out-of-range alarm. "1" means in alarm state. Can
only be turned off with
clear
RELAY¶
Optionally found on the EDS006X and EDS007X. Can be controlled by software or
the alarm condition.
EDS00XX/relay/control¶
read-write, unsigned
Set the relay control scheme:
- 0
- alarm control with hysteresis
- 1
- alarm control but need EDS00XX/alarm/clear to unset
- 2
- Control with EDS00XX/relay/state
- 3
- Always off
EDS00XX/relay/state¶
read-write, yes-no
Turn the relay on or off if the
EDS00XX/relay/control is set to 2
LED light¶
Found on the EDS006X and EDS007X. Can be controlled by software or the alarm
condition.
EDS00XX/LED/control¶
read-write, unsigned
Set the LED control scheme:
- 0
- alarm control with hysteresis
- 1
- alarm control but need EDS00XX/alarm/clear to unset
- 2
- Control with EDS00XX/LED/state
- 3
- Always off
EDS00XX/LED/state¶
read-write, yes-no
Turn the LED on or off if the
EDS00XX/LED/control is set to 2
COUNTER¶
EDS00XX/counter/seconds¶
read-only, unsigned integer
Approximate seconds since power up.
EDS0090/counter/pulses.0-7 | ALL¶
read-only, unsigned integer
Pulses on each channel since power up or reset. Channel should be set to input (
EDS0090/output/set.x =0 )
EDS0090/counter/reset.0-7 | ALL | BYTE¶
read-write, yes-no
Clear the pulse count on the corresponding channel.
EDS007X/counter/samples¶
read-only, unsigned integer
Approximate samples since power up.
MEMORY¶
memory¶
read-write, binary
96 bytes of memory. Not all is writable. Access to
EDS00XX functions is
better accomplished through the data fields, which expose all the chip
features.
pages/page.0 ... pages/page.2 pages/page.ALL¶
read-write, binary
Memory is split into 3 pages of 32 bytes each. Only page 2 is writable.
ALL is an aggregate of the pages. Each page is accessed sequentially.
EDS008X/memory¶
read-write, binary
160 bytes of memory. Not all is writable. Access to
EDS008X functions is
better accomplished through the data fields, which expose all the chip
features. The
EDS008X has more memory than the other chips, so a
separate entry in the sudbirectory makes it available.
EDS008X/pages/page.0-4 EDS008X/pages/page.ALL¶
read-write, binary
Memory is split into 5 pages of 32 bytes each. Only page 5 is writable. The
EDS008X has more memory than the other chips, so a separate entry in
the sudbirectory makes the extra pages available.
ALL is an aggregate
of the pages. Each page is accessed sequentially.
SUB-TYPE¶
tag¶
read-only, ascii
Text description of the device. Up to 30 characters.
device_type¶
read-only, ascii
Device name. E.g: "EDS0071"
device_id¶
read-only, unsigned
Number corresponding to the hexidecimal type. E.g:
EDS0071 -> 0x0071 -> 113 in decimal
STANDARD PROPERTIES¶
address¶
r_address¶
read-only, ascii
The entire 64-bit unique ID. Given as upper case hexidecimal digits (0-9A-F).
address starts with the
family code
r address is the
address in reverse order, which is often used in
other applications and labeling.
crc8¶
read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed from
the preceding 56 bits of the unique ID number. Given as upper case hexidecimal
digits (0-9A-F).
family¶
read-only, ascii
The 8-bit family code. Unique to each
type of device. Given as upper case
hexidecimal digits (0-9A-F).
r_id¶
read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the family
code or CRC. Given as upper case hexidecimal digits (0-9A-F).
r id is the
id in reverse order, which is often used in other
applications and labeling.
locator¶
r_locator¶
read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that associated
1-wire physical connections with a unique 1-wire code. If the connection is
behind a
Link Locator the
locator will show a unique 8-byte number
(16 character hexidecimal) starting with family code FE.
If no
Link Locator is between the device and the master, the
locator field will be all FF.
r locator is the
locator in reverse order.
present (DEPRECATED)¶
read-only, yes-no
Is the device currently
present on the 1-wire bus?
type¶
read-only, ascii
Part name assigned by Dallas Semi. E.g.
DS2401 Alternative packaging
(iButton vs chip) will not be distiguished.
ALARMS¶
None.
DESCRIPTION¶
1-Wire¶
1-wire is a wiring protocol and series of devices designed and
manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed
low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a
wide variety of devices, including memory, sensors (humidity, temperature,
voltage, contact, current), switches, timers and data loggers. More complex
devices (like thermocouple sensors) can be built with these basic devices.
There are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single
bus master and multiple
slaves on
the same wire. The bus master initiates all communication. The slaves can be
individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c,
network or USB adapters.
OWFS design¶
OWFS is a suite of programs that designed to make the 1-wire bus and its
devices easily accessible. The underlying priciple is to create a virtual
filesystem, with the unique ID being the directory, and the individual
properties of the device are represented as simple files that can be read and
written.
Details of the individual slave or master design are hidden behind a consistent
interface. The goal is to provide an easy set of tools for a software designer
to create monitoring or control applications. There are some performance
enhancements in the implementation, including data caching, parallel access to
bus masters, and aggregation of device communication. Still the fundemental
goal has been ease of use, flexibility and correctness rather than speed.
EDS00XX Overview¶
The EDS00XX sensors are a family of devices from
Embedded Data Systems.
Although provisional support for several types is included, only early
EDS0071 has been tested with
OWFS.
The sensors all share the same
7E family code. They have the same first
memory page layout with a text
tag property that describes them, and a
sub-type field giving the particular sensor. The data properties shown
in a directory listing will be specific to the sensor
sub-type.
EDS0071¶
The
EDS0071 (3) is a micro-processor based 1-wire slave made by EDS
(Embedded Data Systams). Is uses a high accuracy and extended range RTD sensor
to accurately measure temperatures.
Memory¶
The
EDS00XX sensors are read and controlled by accessing parts of their
on-chip memory. Although the raw memory contents are exposed in the
memory and
pages fields, all the available functionality is best
accessed by the other fields. In fact, directly changing memory will confuse
OWFS.
Relay and LED¶
All the
EDS00XX sensors have an LED and optional relay. Both can be
controlled either directly, or when the sensors reaches an alarm state.
ADDRESSING¶
All 1-wire devices are factory assigned a unique 64-bit address. This address is
of the form:
- Family Code
- 8 bits
- Address
- 48 bits
- CRC
- 8 bits
Addressing under OWFS is in hexidecimal, of form:
- 01.123456789ABC
where
01 is an example 8-bit family code, and
12345678ABC is an
example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be
correct.
DATASHEET¶
- EDS0064 EDS0065 EDS0066 EDS0067 EDS0068
- https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vN2E4NGUwMGItMzc5MS00NDNmLTljZGYtN2NmM2Q3YWE5NmVh&hl=en
- EDS0070
- http://www.embeddeddatasystems.com/assets/images/supportFiles/manuals/EN-UserMan%20%20OW-Vibration%20V01.pdf
- EDS0071 EDS0072
- https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vMjVhNWQzYzItZTRhMi00NGY2LWI4NTQtYjZlYTgzYzY0NmNm&hl=en
- EDS0080 EDS0083
- https://eds.zendesk.com/attachments/token/ulnpj6mvpp6yzwo/?name=EN-USERMAN+OW-IO-AIX-420+v1p0.pdf
- EDS0082 EDS0085
- https://eds.zendesk.com/attachments/token/vyai6ylpw6edala/?name=EN-USERMAN+OW-IO-AIX-10V+v1p0.pdf
- EDS0090
- 8 Discrete I/O
SEE ALSO¶
Programs¶
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1)
owwrite (1) owpresent (1) owtap (1)
Configuration and testing¶
owfs (5) owtap (1) owmon (1)
Language bindings¶
owtcl (3) owperl (3) owcapi (3)
Clocks¶
DS1427 (3) DS1904(3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417
(3)
DS2401 (3) DS2411 (3) DS1990A (3)
Memory¶
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3)
DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3)
DS28EC20 (3)
Switches¶
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)
Temperature¶
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921
(3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3)
EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)
Humidity¶
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
Voltage¶
DS2450 (3)
Resistance¶
DS2890 (3)
Multifunction (current, voltage, temperature)¶
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3)
DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)
Counter¶
DS2423 (3)
LCD Screen¶
LCD (3) DS2408 (3)
Crypto¶
DS1977 (3)
Pressure¶
DS2406 (3) TAI8570 EDS0066 (3) EDS0068 (3)
Moisture¶
EEEF (3) DS2438 (3)
AVAILABILITY¶
http://www.owfs.org
AUTHOR¶