table of contents
other versions
- jessie-backports 1.1.16-1~bpo8+1
- stretch 1.1.16-1
- testing 2.0.1~rc4-1
- unstable 2.0.1~rc5-1
OCF_PACEMAKER_HEALTH(7) | Pacemaker Configuration | OCF_PACEMAKER_HEALTH(7) |
NAME¶
ocf_pacemaker_HealthSMART - SMART health statusSYNOPSIS¶
OCF_RESKEY_state=string [OCF_RESKEY_drives=string] [OCF_RESKEY_devices=string] [ OCF_RESKEY_temp_lower_limit=string] [ OCF_RESKEY_temp_upper_limit=string] [ OCF_RESKEY_temp_warning=string] HealthSMART [start | stop | monitor | meta-data | validate-all]DESCRIPTION¶
Systhem health agent that checks the S.M.A.R.T. status of the given drives and updates the #health-smart attribute.SUPPORTED PARAMETERS¶
OCF_RESKEY_state = string [/HealthSMART-.state]State file
Location to store the resource state in.
OCF_RESKEY_drives = string [/dev/sda]
Drives to check
The drive(s) to check as a SPACE separated list. Enter the full path to the
device, e.g. "/dev/sda".
OCF_RESKEY_devices = string
Device types
The device type(s) to assume for the drive(s) being tested as a SPACE separated
list.
OCF_RESKEY_temp_lower_limit = string [0]
Lower limit for the red smart attribute
Lower limit of the temperature in deg C of the drive(s). Below this limit the
status will be red.
OCF_RESKEY_temp_upper_limit = string [60]
Upper limit for red smart attribute
Upper limit of the temperature if deg C of the drives(s). If the drive reports a
temperature higher than this value the status of #health-smart will be
red.
OCF_RESKEY_temp_warning = string [5]
Deg C below/above the upper limits for yellow smart
attribute
Number of deg C below/above the upper/lower temp limits at which point the
status of #health-smart will change to yellow.
AUTHOR¶
Andrew Beekhof <andrew@beekhof.net>Author.
06/07/2017 | Pacemaker Configuration |