.\" nmcli (1) manual page .\" .\" This is free documentation; you can redistribute it and/or .\" modify it under the terms of the GNU General Public License as .\" published by the Free Software Foundation; either version 2 of .\" the License, or (at your option) any later version. .\" .\" The GNU General Public License's references to "object code" .\" and "executables" are to be interpreted as the output of any .\" document formatting or typesetting system, including .\" intermediate and printed output. .\" .\" This manual is distributed in the hope that it will be useful, .\" but WITHOUT ANY WARRANTY; without even the implied warranty of .\" MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the .\" GNU General Public License for more details. .\" .\" You should have received a copy of the GNU General Public .\" License along with this manual; if not, write to the Free .\" Software Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111, .\" USA. .\" .\" Copyright (C) 2010 - 2011 Red Hat, Inc. .\" .TH NMCLI "1" "6 September 2011" .SH NAME nmcli \- command-line tool for controlling NetworkManager .SH SYNOPSIS .ad l .B nmcli .RI " [ " OPTIONS " ] " OBJECT " { " COMMAND " | " .BR help " } " .sp .IR OBJECT " := { " .BR nm " | " con " | " dev " } " .sp .IR OPTIONS " := { " .br \fB\-t\fR[\fIerse\fR] .br \fB\-p\fR[\fIretty\fR] .br \fB\-m\fR[\fImode\fR] tabular | multiline .br \fB\-f\fR[\fIields\fR] | all | common .br \fB\-e\fR[\fIscape\fR] yes | no .br \fB\-v\fR[\fIersion\fR] .br \fB\-h\fR[\fIelp\fR] .br .RI "}" .SH DESCRIPTION .B nmcli is a command-line tool for controlling NetworkManager and getting its status. It is not meant as a replacement of \fInm-applet\fP or other similar clients. Rather it's a complementary utility to these programs. The main \fInmcli\fP's usage is on servers, headless machines or just for power users who prefer the command line. .P The use cases comprise: .IP \(em 4 Initscripts: ifup/ifdown can utilize NetworkManager via \fInmcli\fP instead of having to manage connections itself and possibly interfere with NetworkManager. .IP \(em 4 Servers, headless machines: No GUI is available; then \fInmcli\fP can be used to activate/deactivate connections. However, if a connection requires a secret to activate and if that secret is not stored at the system level, \fInmcli\fP will not be able to activate it; it is currently unable to supply the needed secrets to NetworkManager. .IP \(em 4 User sessions: \fInmcli\fP can be used activate/deactivate connections from the command line, but a full NetworkManager client (like \fInm-applet\fP) is used for supplying secrets not stored at the system level. Keyring dialogs and password prompts may appear if this happens. .SS \fIOPTIONS\fP .TP .B \-t, \-\-terse Output is terse. This mode is designed and suitable for computer (script) processing. .TP .B \-p, \-\-pretty Output is pretty. This causes \fInmcli\fP to produce easy readable outputs for humans, i.e. values are aligned, headers are printed, etc. .TP .B \-m, \-\-mode tabular | multiline Switch between \fItabular\fP and \fImultiline\fP output. If omitted, default is \fItabular\fP for most commands. For the commands producing more structured information, that cannot be displayed on a single line, default is \fImultiline\fP. Currenly, they are: .br .nf 'nmcli con list id|uuid ' 'nmcli dev list' .fi \fItabular\fP - Output is a table where each line describes a single entry. Columns define particular properties of the entry. .br \fImultiline\fP - Each entry comprises more lines, each property on its own line. The values are prefixed with the property name. .TP .B \-f, \-\-fields | all | common This option is used to specify what fields (column names) should be printed. Valid field names differ for specific commands. List available fields by providing an invalid value to the \fI--fields\fP option. .br \fIall\fP is used to print all valid field values of the command. \fIcommon\fP is used to print common field values of the command. If omitted, default is \fIcommon\fP. The option is mandatory when \fI--terse\fP is used. In this case, generic values \fIall\fP and \fIcommon\fP cannot be used. (This is to maintain compatibility when new fields are added in the future). .TP .B \-e, \-\-escape yes | no Whether to escape ':' and '\\' characters in terse tabular mode. The escape character is '\\'. If omitted, default is \fIyes\fP. .TP .B \-v, \-\-version Show \fInmcli\fP version. .TP .B \-h, \-\-help Print help information. .SS \fIOBJECT\fP .TP .B nm NetworkManager .br Use this object to inquire and change state of NetworkManager. .TP .SS \fICOMMAND\fP := { status | enable | sleep | wifi | wwan } .sp .RS .TP .B status .br Show overall status of NetworkManager. This is the default action, when no command is provided to \fInm\fP object. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .TP .B enable [true|false] .br Get networking-enabled status or enable/disable networking by NetworkManager. All interfaces managed by NetworkManager are deactivated when networking has been disabled. .br .nf \fBReference to D-Bus:\fP interface: org.freedesktop.NetworkManager method: Enable arguments: TRUE or FALSE .fi .TP .B sleep [true|false] .br Get sleep status or put to sleep/awake NetworkManager. All interfaces managed by NetworkManager are deactivated when it falls asleep. This command is not meant for user to enable/disable networking, use \fIenable\fP for that. D-Bus \fISleep\fP method is designed to put NetworkManager to sleep or awake for suspending/resuming computer. .br .nf \fBReference to D-Bus:\fP interface: org.freedesktop.NetworkManager method: Sleep arguments: TRUE or FALSE .fi .TP .B wifi [on|off] .br Inquire or set status of WiFi in NetworkManager. Without any further argument, WiFi status is printed; \fIon\fP enables WiFi; \fIoff\fP disables WiFi. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .TP .B wwan [on|off] .br Inquire or set status of WWAN in NetworkManager. Without any further argument, WWAN status is printed; \fIon\fP enables WWAN; \fIoff\fP disables WWAN. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .RE .TP .B con Connections .br Get information about NetworkManager's connections. .TP .SS \fICOMMAND\fP := { list | status | up | down | delete } .sp .RS .TP .B list [id | uuid ] .br List configured connections. Without a parameter, all connections are listed. In order to get connection details, \fIid\fP with connection's name or \fIuuid\fP with connection's UUID shall be specified. When no command is given to the \fIcon\fP object, the default action is 'nmcli con list'. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .TP .B status .br Print status of active connections. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .TP .B up id | uuid [iface ] [ap ] [\-\-nowait] [\-\-timeout ] .br Activate a connection. The connection is identified by its name using \fIid\fP or UUID using \fIuuid\fP. For requiring particular device to activate the connection on, \fIiface\fP option with interface name should be given. \fIap\fP option can further concretize what AP should be used in case of WiFi connection. \fI\-\-nowait\fP option causes \fInmcli\fP to exit immediately and not to wait for command completion. \fI\-\-timeout\fP option provides a means to specify how long to wait for operation completion. .br .nf \fBReference to D-Bus:\fP interface: org.freedesktop.NetworkManager method: ActivateConnection arguments: according to arguments .fi .TP .B down id | uuid .br Deactivate a connection. The connection is identified by its name using \fIid\fP or UUID using \fIuuid\fP. .br .nf \fBReference to D-Bus:\fP interface: org.freedesktop.NetworkManager method: DeactivateConnection arguments: according to arguments .fi .TP .B delete id | uuid .br Delete a configured connection. The connection to delete is specified with \fIid\fP (connection name) or \fIuuid\fP (connection UUID). .br .nf \fBReference to D-Bus:\fP interface: org.freedesktop.NetworkManager.Settings.Connection method: Delete arguments: none .fi .RE .TP .B dev Devices .br Get information about devices. .TP .SS \fICOMMAND\fP := { status | list | disconnect | wifi } .sp .RS .TP .B status .br Print status of devices. This is the default action, when no command is specified to \fIdev\fP object. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .TP .B list [iface ] .br Get detailed information about devices. Without an argument, all devices are examined. To get information for a specific device, \fIiface\fP argument with the interface name should be provided. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .TP .B disconnect iface [\-\-nowait] [\-\-timeout ] .br Disconnect a device and prevent the device from automatically activating further connections without user/manual intervention. \fI\-\-nowait\fP option causes \fInmcli\fP to exit immediately and not to wait for command completion. \fI\-\-timeout\fP option provides a means to specify how long to wait for operation completion. .br .nf \fBReference to D-Bus:\fP interface: org.freedesktop.NetworkManager.Device method: Disconnect arguments: none .fi .TP .B wifi [list [iface ] [bssid ]] .br List available WiFi access points. \fIiface\fP and \fIbssid\fP options can be used to get just APs for particular interface or specific AP, respectively. .br .nf \fBReference to D-Bus:\fP No simple reference. .fi .RE .SH ENVIRONMENT VARIABLES \fInmcli\fP's behavior is affected by the following environment variables. .IP "LC_ALL" 13 If set to a non-empty string value, override the values of all the other internationalization variables. .IP "LC_MESSAGES" 13 Determines the locale to be used for internationalised messages. .IP "LANG" 13 Provides a default value for the internationalization variables that are unset or null. .RE Notes about localization: .br Be aware that \fInmcli\fP is localized and that's why the output depends on your environment. It's important to realize that especially when you parse the output. .br Call \fInmcli\fP as \fBLC_ALL=C nmcli\fP to be sure the locale is set to "C" while executing in a script. \fBLC_ALL\fP, \fBLC_MESSAGES\fP, \fBLANG\fP variables specify the LC_MESSAGES locale category (in that order), which determines the language that \fInmcli\fP uses for messages. The "C" locale is used if none of these variables are set, and this locale uses English messages. .SH EXIT STATUS \fInmcli\fP exits with status 0 if it succeeds, a value greater than 0 is returned if errors occur. .IP "0" 4 Success - indicates the operation succeeded .IP "1" 4 Unknown or unspecified error .IP "2" 4 Invalid user input, wrong \fInmcli\fP invocation .IP "3" 4 Timeout expired (see commands with \fI\-\-timeout\fP option) .IP "4" 4 Connection activation failed .IP "5" 4 Connection deactivation failed .IP "6" 4 Disconnecting device failed .SH BUGS There are probably some. If you find a bug, please report to https://bugzilla.gnome.org/ \- product \fINetworkManager\fP. .SH SEE ALSO .BR nm\-tool (1), .BR nm\-online (1), .BR NetworkManager(8).