.SH "NAME"
modbus_read_registers \- read many registers
.SH "SYNOPSIS"
.sp
\fBint modbus_read_registers(modbus_t *\fR\fB\fIctx\fR\fR\fB, int \fR\fB\fIaddr\fR\fR\fB, int \fR\fB\fInb\fR\fR\fB, uint16_t *\fR\fB\fIdest\fR\fR\fB);\fR
.SH "DESCRIPTION"
.sp
The \fBmodbus_read_registers()\fR function shall read the content of the \fInb\fR holding registers to the address \fIaddr\fR of the remote device\&. The result of reading is stored in \fIdest\fR array as word values (16 bits)\&.
.sp
You must take care to allocate enough memory to store the results in \fIdest\fR (at least \fInb\fR * sizeof(uint16_t))\&.
.sp
The function uses the Modbus function code 0x03 (read holding registers)\&.
.SH "RETURN VALUE"
.sp
The function shall return the number of read registers if successful\&. Otherwise it shall return \-1 and set errno\&.
.SH "ERRORS"
.PP
\fBEMBMDATA\fR
.RS 4
Too many registers requested
.RE
.SH "EXAMPLE"
.sp
.if n \{\
.RS 4
.\}
.nf
modbus_t *ctx;
uint16_t tab_reg[64];
int rc;
int i;
ctx = modbus_new_tcp("127\&.0\&.0\&.1", 1502);
if (modbus_connect(ctx) == \-1) {
fprintf(stderr, "Connection failed: %s\en", modbus_strerror(errno));
modbus_free(ctx);
return \-1;
}
rc = modbus_read_registers(ctx, 0, 10, tab_reg);
if (rc == \-1) {
fprintf(stderr, "%s\en", modbus_strerror(errno));
return \-1;
}
for (i=0; i < rc; i++) {
printf("reg[%d]=%d (0x%X)\en", i, tab_reg[i], tab_reg[i]);
}
modbus_close(ctx);
modbus_free(ctx);
.fi
.if n \{\
.RE
.\}
.SH "SEE ALSO"
.sp
\fBmodbus_write_register\fR(3) \fBmodbus_write_registers\fR(3)
.SH "AUTHORS"
.sp
The libmodbus documentation was written by Stéphane Raimbault