.SH "NAME"
modbus_new_rtu \- create a libmodbus context for RTU
.SH "SYNOPSIS"
.sp
\fBmodbus_t *modbus_new_rtu(const char *\fR\fB\fIdevice\fR\fR\fB, int \fR\fB\fIbaud\fR\fR\fB, char \fR\fB\fIparity\fR\fR\fB, int \fR\fB\fIdata_bit\fR\fR\fB, int \fR\fB\fIstop_bit\fR\fR\fB);\fR
.SH "DESCRIPTION"
.sp
The \fBmodbus_new_rtu()\fR function shall allocate and initialize a \fImodbus_t\fR structure to communicate in RTU mode on a serial line\&.
.sp
The \fIdevice\fR argument specifies the name of the serial port handled by the OS, eg\&. "/dev/ttyS0" or "/dev/ttyUSB0"\&. On Windows, it\(cqs necessary to prepend COM name with "\e\e\&.\e" for COM number greater than 9, eg\&. "\e\e\e\e\&.\e\eCOM10"\&. See http://msdn\&.microsoft\&.com/en\-us/library/aa365247(v=vs\&.85)\&.aspx for details
.sp
The \fIbaud\fR argument specifies the baud rate of the communication, eg\&. 9600, 19200, 57600, 115200, etc\&.
.PP
The \fIparity\fR argument can have one of the following values
.RS 4
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
\fIN\fR
for none
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
\fIE\fR
for even
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
\fIO\fR
for odd
.RE
.RE
.sp
The \fIdata_bits\fR argument specifies the number of bits of data, the allowed values are 5, 6, 7 and 8\&.
.sp
The \fIstop_bits\fR argument specifies the bits of stop, the allowed values are 1 and 2\&.
.sp
Once the \fImodbus_t\fR structure is initialized, you must set the slave of your device with \fBmodbus_set_slave\fR(3) and connect to the serial bus with \fBmodbus_connect\fR(3)\&.
.SH "RETURN VALUE"
.sp
The function shall return a pointer to a \fImodbus_t\fR structure if successful\&. Otherwise it shall return NULL and set errno to one of the values defined below\&.
.SH "ERRORS"
.PP
\fBEINVAL\fR
.RS 4
An invalid argument was given\&.
.RE
.PP
\fBENOMEM\fR
.RS 4
Out of memory\&. Possibly, the application hits its memory limit and/or whole system is running out of memory\&.
.RE
.SH "EXAMPLE"
.sp
.if n \{\
.RS 4
.\}
.nf
modbus_t *ctx;
ctx = modbus_new_rtu("/dev/ttyUSB0", 115200, \*(AqN\*(Aq, 8, 1);
if (ctx == NULL) {
fprintf(stderr, "Unable to create the libmodbus context\en");
return \-1;
}
modbus_set_slave(ctx, YOUR_DEVICE_ID);
if (modbus_connect(ctx) == \-1) {
fprintf(stderr, "Connection failed: %s\en", modbus_strerror(errno));
modbus_free(ctx);
return \-1;
}