.\" Automatically generated by Pod::Man 2.28 (Pod::Simple 3.29) .\" .\" Standard preamble: .\" ======================================================================== .de Sp \" Vertical space (when we can't use .PP) .if t .sp .5v .if n .sp .. .de Vb \" Begin verbatim text .ft CW .nf .ne \\$1 .. .de Ve \" End verbatim text .ft R .fi .. .\" Set up some character translations and predefined strings. \*(-- will .\" give an unbreakable dash, \*(PI will give pi, \*(L" will give a left .\" double quote, and \*(R" will give a right double quote. \*(C+ will .\" give a nicer C++. Capital omega is used to do unbreakable dashes and .\" therefore won't be available. \*(C` and \*(C' expand to `' in nroff, .\" nothing in troff, for use with C<>. .tr \(*W- .ds C+ C\v'-.1v'\h'-1p'\s-2+\h'-1p'+\s0\v'.1v'\h'-1p' .ie n \{\ . ds -- \(*W- . ds PI pi . if (\n(.H=4u)&(1m=24u) .ds -- \(*W\h'-12u'\(*W\h'-12u'-\" diablo 10 pitch . if (\n(.H=4u)&(1m=20u) .ds -- \(*W\h'-12u'\(*W\h'-8u'-\" diablo 12 pitch . ds L" "" . ds R" "" . ds C` . ds C' 'br\} .el\{\ . ds -- \|\(em\| . ds PI \(*p . ds L" `` . ds R" '' . ds C` . ds C' 'br\} .\" .\" Escape single quotes in literal strings from groff's Unicode transform. .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" .\" If the F register is turned on, we'll generate index entries on stderr for .\" titles (.TH), headers (.SH), subsections (.SS), items (.Ip), and index .\" entries marked with X<> in POD. Of course, you'll have to process the .\" output yourself in some meaningful fashion. .\" .\" Avoid warning from groff about undefined register 'F'. .de IX .. .nr rF 0 .if \n(.g .if rF .nr rF 1 .if (\n(rF:(\n(.g==0)) \{ . if \nF \{ . de IX . tm Index:\\$1\t\\n%\t"\\$2" .. . if !\nF==2 \{ . nr % 0 . nr F 2 . \} . \} .\} .rr rF .\" .\" Accent mark definitions (@(#)ms.acc 1.5 88/02/08 SMI; from UCB 4.2). .\" Fear. Run. Save yourself. No user-serviceable parts. . \" fudge factors for nroff and troff .if n \{\ . ds #H 0 . ds #V .8m . ds #F .3m . ds #[ \f1 . ds #] \fP .\} .if t \{\ . ds #H ((1u-(\\\\n(.fu%2u))*.13m) . ds #V .6m . ds #F 0 . ds #[ \& . ds #] \& .\} . \" simple accents for nroff and troff .if n \{\ . ds ' \& . ds ` \& . ds ^ \& . ds , \& . ds ~ ~ . ds / .\} .if t \{\ . ds ' \\k:\h'-(\\n(.wu*8/10-\*(#H)'\'\h"|\\n:u" . ds ` \\k:\h'-(\\n(.wu*8/10-\*(#H)'\`\h'|\\n:u' . ds ^ \\k:\h'-(\\n(.wu*10/11-\*(#H)'^\h'|\\n:u' . ds , \\k:\h'-(\\n(.wu*8/10)',\h'|\\n:u' . ds ~ \\k:\h'-(\\n(.wu-\*(#H-.1m)'~\h'|\\n:u' . ds / \\k:\h'-(\\n(.wu*8/10-\*(#H)'\z\(sl\h'|\\n:u' .\} . \" troff and (daisy-wheel) nroff accents .ds : \\k:\h'-(\\n(.wu*8/10-\*(#H+.1m+\*(#F)'\v'-\*(#V'\z.\h'.2m+\*(#F'.\h'|\\n:u'\v'\*(#V' .ds 8 \h'\*(#H'\(*b\h'-\*(#H' .ds o \\k:\h'-(\\n(.wu+\w'\(de'u-\*(#H)/2u'\v'-.3n'\*(#[\z\(de\v'.3n'\h'|\\n:u'\*(#] .ds d- \h'\*(#H'\(pd\h'-\w'~'u'\v'-.25m'\f2\(hy\fP\v'.25m'\h'-\*(#H' .ds D- D\\k:\h'-\w'D'u'\v'-.11m'\z\(hy\v'.11m'\h'|\\n:u' .ds th \*(#[\v'.3m'\s+1I\s-1\v'-.3m'\h'-(\w'I'u*2/3)'\s-1o\s+1\*(#] .ds Th \*(#[\s+2I\s-2\h'-\w'I'u*3/5'\v'-.3m'o\v'.3m'\*(#] .ds ae a\h'-(\w'a'u*4/10)'e .ds Ae A\h'-(\w'A'u*4/10)'E . \" corrections for vroff .if v .ds ~ \\k:\h'-(\\n(.wu*9/10-\*(#H)'\s-2\u~\d\s+2\h'|\\n:u' .if v .ds ^ \\k:\h'-(\\n(.wu*10/11-\*(#H)'\v'-.4m'^\v'.4m'\h'|\\n:u' . \" for low resolution devices (crt and lpr) .if \n(.H>23 .if \n(.V>19 \ \{\ . ds : e . ds 8 ss . ds o a . ds d- d\h'-1'\(ga . ds D- D\h'-1'\(hy . ds th \o'bp' . ds Th \o'LP' . ds ae ae . ds Ae AE .\} .rm #[ #] #H #V #F C .\" ======================================================================== .\" .IX Title "GVPE.CONF 5" .TH GVPE.CONF 5 "2016-11-12" "3.0" "GNU Virtual Private Ethernet" .\" For nroff, turn off justification. Always turn off hyphenation; it makes .\" way too many mistakes in technical documents. .if n .ad l .nh .SH "NAME" gvpe.conf \- configuration file for the GNU VPE daemon .SH "SYNOPSIS" .IX Header "SYNOPSIS" .Vb 4 \& # global options for all nodes \& udp\-port = 407 \& mtu = 1492 \& ifname = vpn0 \& \& # first node is named branch1 and is at 1.2.3.4 \& node = branch1 \& hostname = 1.2.3.4 \& \& # second node uses dns to resolve the address \& node = branch2 \& hostname = www.example.net \& udp\-port = 500 # this host uses a different udp\-port \& \& # third node has no fixed ip address \& node = branch3 \& connect = ondemand .Ve .SH "DESCRIPTION" .IX Header "DESCRIPTION" The gvpe config file consists of a series of lines that contain \f(CW\*(C`variable = value\*(C'\fR pairs. Empty lines are ignored. Comments start with a \f(CW\*(C`#\*(C'\fR and extend to the end of the line. They can be used on their own lines, or after any directives. Whitespace is allowed around the \f(CW\*(C`=\*(C'\fR sign or after values, but not within the variable names or values themselves. .PP All settings are applied \*(L"in order\*(R", that is, later settings of the same variable overwrite earlier ones. .PP The only exceptions to the above are the following directives: .IP "node nodename" 4 .IX Item "node nodename" Introduces a node section. The nodename is used to select the right configuration section and is the same string as is passed as an argument to the gvpe daemon. .Sp Multiple \f(CW\*(C`node\*(C'\fR statements with the same node name are supported and will be merged together. .IP "global" 4 .IX Item "global" This statement switches back to the global section, which is mainly useful if you want to include a second config file, e..g for local customisations. To do that, simply include this at the very end of your config file: .Sp .Vb 2 \& global \& include local.conf .Ve .IP "on nodename ..." 4 .IX Item "on nodename ..." .PD 0 .IP "on !nodename ..." 4 .IX Item "on !nodename ..." .PD You can prefix any configuration directive with \f(CW\*(C`on\*(C'\fR and a nodename. \s-1GVPE\s0 will will only \*(L"execute\*(R" it on the named node, or (if the nodename starts with \f(CW\*(C`!\*(C'\fR) on all nodes except the named one. .Sp Example: set the \s-1MTU\s0 to \f(CW1450\fR everywhere, \f(CW\*(C`loglevel\*(C'\fR to \f(CW\*(C`noise\*(C'\fR on \&\f(CW\*(C`branch1\*(C'\fR, and \f(CW\*(C`connect\*(C'\fR to \f(CW\*(C`ondemand\*(C'\fR everywhere but on branch2. .Sp .Vb 3 \& mtu = 1450 \& on branch1 loglevel = noise \& on !branch2 connect = ondemand .Ve .IP "include relative-or-absolute-path" 4 .IX Item "include relative-or-absolute-path" Reads the specified file (the path must not contain whitespace or \f(CW\*(C`=\*(C'\fR characters) and evaluate all config directives in it as if they were spelled out in place of the \f(CW\*(C`include\*(C'\fR directive. .Sp The path is a printf format string, that is, you must escape any \f(CW\*(C`%\*(C'\fR by doubling it, and you can have a single \f(CW%s\fR inside, which will be replaced by the current nodename. .Sp Relative paths are interpreted relative to the \s-1GVPE\s0 config directory. .Sp Example: include the file \fIlocal.conf\fR in the config directory on every node. .Sp .Vb 1 \& include local.conf .Ve .Sp Example: include a file \fIconf/\fRnodename\fI.conf\fR .Sp .Vb 1 \& include conf/%s.conf .Ve .SH "ANATOMY OF A CONFIG FILE" .IX Header "ANATOMY OF A CONFIG FILE" Usually, a config file starts with a few global settings (like the \s-1UDP\s0 port to listen on), followed by node-specific sections that begin with a \&\f(CW\*(C`node = nickname\*(C'\fR line. .PP Every node that is part of the network must have a section that starts with \f(CW\*(C`node = nickname\*(C'\fR. The number and order of the nodes is important and must be the same on all nodes. It is not uncommon for node sections to be completely empty \- if the default values are right. .PP Node-specific settings can be used at any time. If used before the first node section they will set the default values for all following nodes. .SH "CONFIG VARIABLES" .IX Header "CONFIG VARIABLES" .SS "\s-1GLOBAL SETTINGS\s0" .IX Subsection "GLOBAL SETTINGS" Global settings will affect the behaviour of the running gvpe daemon, that is, they are in some sense node-specific (config files can set different values on different nodes using \f(CW\*(C`on\*(C'\fR), but will affect the behaviour of the gvpe daemon and all connections it creates. .IP "chroot = path or /" 4 .IX Item "chroot = path or /" Tells \s-1GVPE\s0 to \fIchroot\fR\|(2) to the specified path after reading all necessary files, binding to sockets and running the \f(CW\*(C`if\-up\*(C'\fR script, but before running \f(CW\*(C`node\-up\*(C'\fR or any other scripts. .Sp The special path \fI/\fR instructs \s-1GVPE\s0 to create (and remove) an empty temporary directory to use as new root. This is most secure, but makes it impossible to use any scripts other than the \f(CW\*(C`if\-up\*(C'\fR one. .IP "chuid = numerical-uid" 4 .IX Item "chuid = numerical-uid" .PD 0 .IP "chgid = numerical-gid" 4 .IX Item "chgid = numerical-gid" .PD These two options tell \s-1GVPE\s0 to change to the given user and/or group id after reading all necessary files, binding to sockets and running the \&\f(CW\*(C`if\-up\*(C'\fR script. .Sp Other scripts, such as \f(CW\*(C`node\-up\*(C'\fR, are run with the new user id or group id. .IP "chuser = username" 4 .IX Item "chuser = username" Alternative to \f(CW\*(C`chuid\*(C'\fR and \f(CW\*(C`chgid\*(C'\fR: Sets both \f(CW\*(C`chuid\*(C'\fR and \f(CW\*(C`chgid\*(C'\fR to the user and (primary) group ids of the specified user (for example, \&\f(CW\*(C`nobody\*(C'\fR). .IP "dns-forw-host = hostname/ip" 4 .IX Item "dns-forw-host = hostname/ip" The \s-1DNS\s0 server to forward \s-1DNS\s0 requests to for the \s-1DNS\s0 tunnel protocol (default: \f(CW127.0.0.1\fR, changing it is highly recommended). .IP "dns-forw-port = port-number" 4 .IX Item "dns-forw-port = port-number" The port where the \f(CW\*(C`dns\-forw\-host\*(C'\fR is to be contacted (default: \f(CW53\fR, which is fine in most cases). .IP "dns-case-preserving = yes|true|on | no|false|off" 4 .IX Item "dns-case-preserving = yes|true|on | no|false|off" Sets whether the \s-1DNS\s0 transport forwarding server preserves case (\s-1DNS\s0 servers have to, but some access systems are even more broken than others) (default: true). .Sp Normally, when the forwarding server changes the case of domain names then \&\s-1GVPE\s0 will automatically set this to false. .IP "dns-max-outstanding = integer-number-of-requests" 4 .IX Item "dns-max-outstanding = integer-number-of-requests" The maximum number of outstanding \s-1DNS\s0 transport requests (default: \f(CW100\fR). \s-1GVPE\s0 will never issue more requests then the given limit without receiving replies. In heavily overloaded situations it might help to set this to a low number (e.g. \f(CW3\fR or even \f(CW1\fR) to limit the number of parallel requests. .Sp The default should be working \s-1OK\s0 for most links. .IP "dns-overlap-factor = float" 4 .IX Item "dns-overlap-factor = float" The \s-1DNS\s0 transport uses the minimum request latency (\fBmin_latency\fR) seen during a connection as it's timing base. This factor (default: \f(CW0.5\fR, must be > 0) is multiplied by \fBmin_latency\fR to get the maximum sending rate (= minimum send interval), i.e. a factor of \f(CW1\fR means that a new request might be generated every \fBmin_latency\fR seconds, which means on average there should only ever be one outstanding request. A factor of \&\f(CW0.5\fR means that \s-1GVPE\s0 will send requests twice as often as the minimum latency measured. .Sp For congested or picky \s-1DNS\s0 forwarders you could use a value nearer to or exceeding \f(CW1\fR. .Sp The default should be working \s-1OK\s0 for most links. .IP "dns-send-interval = send-interval-in-seconds" 4 .IX Item "dns-send-interval = send-interval-in-seconds" The minimum send interval (= maximum rate) that the \s-1DNS\s0 transport will use to send new \s-1DNS\s0 requests. \s-1GVPE\s0 will not exceed this rate even when the latency is very low. The default is \f(CW0.01\fR, which means \s-1GVPE\s0 will not send more than 100 \s-1DNS\s0 requests per connection per second. For high-bandwidth links you could go lower, e.g. to \f(CW0.001\fR or so. For congested or rate-limited links, you might want to go higher, say \f(CW0.1\fR, \&\f(CW0.2\fR or even higher. .Sp The default should be working \s-1OK\s0 for most links. .IP "dns-timeout-factor = float" 4 .IX Item "dns-timeout-factor = float" Factor to multiply the \f(CW\*(C`min_latency\*(C'\fR (see \f(CW\*(C`dns\-overlap\-factor\*(C'\fR) by to get request timeouts. The default of \f(CW8\fR means that the \s-1DNS\s0 transport will resend the request when no reply has been received for longer than eight times the minimum (= expected) latency, assuming the request or reply has been lost. .Sp For congested links a higher value might be necessary (e.g. \f(CW30\fR). If the link is very stable lower values (e.g. \f(CW2\fR) might work nicely. Values near or below \f(CW1\fR makes no sense whatsoever. .Sp The default should be working \s-1OK\s0 for most links but will result in low throughput if packet loss is high. .IP "if-up = relative-or-absolute-path" 4 .IX Item "if-up = relative-or-absolute-path" Sets the path of a script that should be called immediately after the network interface is initialized (but not necessarily up). The following environment variables are passed to it (the values are just examples). .Sp Variables that have the same value on all nodes: .RS 4 .IP "CONFBASE=/etc/gvpe" 4 .IX Item "CONFBASE=/etc/gvpe" The configuration base directory. .IP "IFNAME=vpn0" 4 .IX Item "IFNAME=vpn0" The network interface to initialize. .IP "IFTYPE=native # or tincd" 4 .IX Item "IFTYPE=native # or tincd" .PD 0 .IP "IFSUBTYPE=linux # or freebsd, darwin etc.." 4 .IX Item "IFSUBTYPE=linux # or freebsd, darwin etc.." .PD The interface type (\f(CW\*(C`native\*(C'\fR or \f(CW\*(C`tincd\*(C'\fR) and the subtype (usually the \&\s-1OS\s0 name in lowercase) that this \s-1GVPE\s0 was configured for. Can be used to select the correct syntax to use for network-related commands. .IP "MTU=1436" 4 .IX Item "MTU=1436" The \s-1MTU\s0 to set the interface to. You can use lower values (if done consistently on all nodes), but this is usually either inefficient or simply ineffective. .IP "NODES=5" 4 .IX Item "NODES=5" The number of nodes in this \s-1GVPE\s0 network. .RE .RS 4 .Sp Variables that are node-specific and with values pertaining to the node running this \s-1GVPE:\s0 .IP "IFUPDATA=string" 4 .IX Item "IFUPDATA=string" The value of the configuration directive \f(CW\*(C`if\-up\-data\*(C'\fR. .IP "MAC=fe:fd:80:00:00:01" 4 .IX Item "MAC=fe:fd:80:00:00:01" The \s-1MAC\s0 address the network interface has to use. .Sp Might be used to initialize interfaces on platforms where \s-1GVPE\s0 does not do this automatically. Please see the \f(CW\*(C`gvpe.osdep(5)\*(C'\fR man page for platform-specific information. .IP "NODENAME=branch1" 4 .IX Item "NODENAME=branch1" The nickname of the node. .IP "NODEID=1" 4 .IX Item "NODEID=1" The numerical node \s-1ID\s0 of the node running this instance of \s-1GVPE.\s0 The first node mentioned in the config file gets \s-1ID 1,\s0 the second \s-1ID 2\s0 and so on. .RE .RS 4 .Sp In addition, all node-specific variables (except \f(CW\*(C`NODEID\*(C'\fR) will be available with a postfix of \f(CW\*(C`_nodeid\*(C'\fR, which contains the value for that node, e.g. the \f(CW\*(C`MAC_1\*(C'\fR variable contains the \s-1MAC\s0 address of node #1, while the \f(CW\*(C`NODENAME_22\*(C'\fR variable contains the name of node #22. .Sp Here is a simple if-up script: .Sp .Vb 5 \& #!/bin/sh \& ip link set $IFNAME up \& [ $NODENAME = branch1 ] && ip addr add 10.0.0.1 dev $IFNAME \& [ $NODENAME = branch2 ] && ip addr add 10.1.0.1 dev $IFNAME \& ip route add 10.0.0.0/8 dev $IFNAME .Ve .Sp More complicated examples (using routing to reduce \s-1ARP\s0 traffic) can be found in the \fIetc/\fR subdirectory of the distribution. .RE .IP "ifname = devname" 4 .IX Item "ifname = devname" Sets the tun interface name to the given name. The default is OS-specific and most probably something like \f(CW\*(C`tun0\*(C'\fR. .IP "ifpersist = yes|true|on | no|false|off" 4 .IX Item "ifpersist = yes|true|on | no|false|off" Should the tun/tap device be made persistent, that is, should the device stay up even when gvpe exits? Some versions of the tunnel device have problems sending packets when gvpe is restarted in persistent mode, so if the connections can be established but you cannot send packets from the local node, try to set this to \f(CW\*(C`off\*(C'\fR and do an ifconfig down on the device. .IP "ip-proto = numerical-ip-protocol" 4 .IX Item "ip-proto = numerical-ip-protocol" Sets the protocol number to be used for the rawip protocol. This is a global option because all nodes must use the same protocol, and since there are no port numbers, you cannot easily run more than one gvpe instance using the same protocol, nor can you share the protocol with other programs. .Sp The default is 47 (\s-1GRE\s0), which has a good chance of tunneling through firewalls (but note that gvpe's rawip protocol is not \s-1GRE\s0 compatible). Other common choices are 50 (\s-1IPSEC, ESP\s0), 51 (\s-1IPSEC, AH\s0), 4 (\s-1IPIP\s0 tunnels) or 98 (\s-1ENCAP,\s0 rfc1241). .Sp Many versions of Linux seem to have a bug that causes them to reorder packets for some ip protocols (\s-1GRE, ESP\s0) but not for others (\s-1AH\s0), so choose wisely (that is, use 51, \s-1AH\s0). .IP "http-proxy-host = hostname/ip" 4 .IX Item "http-proxy-host = hostname/ip" The \f(CW\*(C`http\-proxy\-*\*(C'\fR family of options are only available if gvpe was compiled with the \f(CW\*(C`\-\-enable\-http\-proxy\*(C'\fR option and enable tunneling of tcp connections through a http proxy server. .Sp \&\f(CW\*(C`http\-proxy\-host\*(C'\fR and \f(CW\*(C`http\-proxy\-port\*(C'\fR should specify the hostname and port number of the proxy server. See \f(CW\*(C`http\-proxy\-loginpw\*(C'\fR if your proxy requires authentication. .Sp Please note that gvpe will still try to resolve all hostnames in the configuration file, so if you are behind a proxy without access to a \s-1DNS\s0 server better use numerical \s-1IP\s0 addresses. .Sp To make best use of this option disable all protocols except \s-1TCP\s0 in your config file and make sure your routers (or all other nodes) are listening on a port that the proxy allows (443, https, is a common choice). .Sp If you have a router, connecting to it will suffice. Otherwise \s-1TCP\s0 must be enabled on all nodes. .Sp Example: .Sp .Vb 3 \& http\-proxy\-host = proxy.example.com \& http\-proxy\-port = 3128 # 8080 is another common choice \& http\-proxy\-auth = schmorp:grumbeere .Ve .IP "http-proxy-port = proxy-tcp-port" 4 .IX Item "http-proxy-port = proxy-tcp-port" The port where your proxy server listens. .IP "http-proxy-auth = login:password" 4 .IX Item "http-proxy-auth = login:password" The optional login and password used to authenticate to the proxy server, separated by a literal colon (\f(CW\*(C`:\*(C'\fR). Only basic authentication is currently supported. .IP "keepalive = seconds" 4 .IX Item "keepalive = seconds" Sets the keepalive probe interval in seconds (default: \f(CW60\fR). After this many seconds of inactivity the daemon will start to send keepalive probe every 3 seconds until it receives a reply from the other end. If no reply is received within 15 seconds, the peer is considered unreachable and the connection is closed. .IP "loglevel = noise|trace|debug|info|notice|warn|error|critical" 4 .IX Item "loglevel = noise|trace|debug|info|notice|warn|error|critical" Set the logging level. Connection established messages are logged at level \&\f(CW\*(C`info\*(C'\fR, notable errors are logged with \f(CW\*(C`error\*(C'\fR. Default is \f(CW\*(C`info\*(C'\fR. .IP "mtu = bytes" 4 .IX Item "mtu = bytes" Sets the maximum \s-1MTU\s0 that should be used on outgoing packets (basically the \s-1MTU\s0 of the outgoing interface) The daemon will automatically calculate maximum overhead (e.g. \s-1UDP\s0 header size, encryption blocksize...) and pass this information to the \f(CW\*(C`if\-up\*(C'\fR script. .Sp Recommended values are 1500 (ethernet), 1492 (pppoe), 1472 (pptp). .Sp This value must be the minimum of the \s-1MTU\s0 values of all nodes. .IP "nfmark = integer" 4 .IX Item "nfmark = integer" This advanced option, when set to a nonzero value (default: \f(CW0\fR), tries to set the netfilter mark (or fwmark) value on all sockets gvpe uses to send packets. .Sp This can be used to make gvpe use a different set of routing rules. For example, on GNU/Linux, the \f(CW\*(C`if\-up\*(C'\fR could set \f(CW\*(C`nfmark\*(C'\fR to 1000 and then put all routing rules into table \f(CW99\fR and then use an ip rule to make gvpe traffic avoid that routing table, in effect routing normal traffic via gvpe and gvpe traffic via the normal system routing tables: .Sp .Vb 1 \& ip rule add not fwmark 1000 lookup 99 .Ve .IP "node-up = relative-or-absolute-path" 4 .IX Item "node-up = relative-or-absolute-path" Sets a command (default: none) that should be called whenever a connection is established (even on rekeying operations). Note that node\-up/down scripts will be run asynchronously, but execution is serialised, so there will only ever be one such script running. .Sp In addition to all the variables passed to \f(CW\*(C`if\-up\*(C'\fR scripts, the following environment variables will be set (values are just examples): .RS 4 .IP "DESTNODE=branch2" 4 .IX Item "DESTNODE=branch2" The name of the remote node. .IP "DESTID=2" 4 .IX Item "DESTID=2" The node id of the remote node. .IP "DESTSI=rawip/88.99.77.55:0" 4 .IX Item "DESTSI=rawip/88.99.77.55:0" The \*(L"socket info\*(R" of the target node, protocol dependent but usually in the format protocol/ip:port. .IP "DESTIP=188.13.66.8" 4 .IX Item "DESTIP=188.13.66.8" The numerical \s-1IP\s0 address of the remote node (gvpe accepts connections from everywhere, as long as the other node can authenticate itself). .IP "DESTPORT=655 # deprecated" 4 .IX Item "DESTPORT=655 # deprecated" The protocol port used by the other side, if applicable. .IP "STATE=up" 4 .IX Item "STATE=up" Node-up scripts get called with STATE=up, node-change scripts get called with STATE=change and node-down scripts get called with STATE=down. .RE .RS 4 .Sp Here is a nontrivial example that uses nsupdate to update the name => ip mapping in some \s-1DNS\s0 zone: .Sp .Vb 6 \& #!/bin/sh \& { \& echo update delete $DESTNODE.lowttl.example.net. a \& echo update add $DESTNODE.lowttl.example.net. 1 in a $DESTIP \& echo \& } | nsupdate \-d \-k $CONFBASE:key.example.net. .Ve .RE .IP "node-change = relative-or-absolute-path" 4 .IX Item "node-change = relative-or-absolute-path" Same as \f(CW\*(C`node\-change\*(C'\fR, but gets called whenever something about a connection changes (such as the source \s-1IP\s0 address). .IP "node-down = relative-or-absolute-path" 4 .IX Item "node-down = relative-or-absolute-path" Same as \f(CW\*(C`node\-up\*(C'\fR, but gets called whenever a connection is lost. .IP "pid-file = path" 4 .IX Item "pid-file = path" The path to the pid file to check and create (default: \f(CW\*(C`LOCALSTATEDIR/run/gvpe.pid\*(C'\fR). The first \f(CW%s\fR is replaced by the nodename \- any other use of \f(CW\*(C`%\*(C'\fR must be written as \f(CW\*(C`%%\*(C'\fR. .IP "private-key = relative-path-to-key" 4 .IX Item "private-key = relative-path-to-key" Sets the path (relative to the config directory) to the private key (default: \f(CW\*(C`hostkey\*(C'\fR). This is a printf format string so every \f(CW\*(C`%\*(C'\fR must be doubled. A single \f(CW%s\fR is replaced by the hostname, so you could use paths like \f(CW\*(C`hostkeys/%s\*(C'\fR to be able to share the same config directory between nodes. .Sp Since only the private key file of the current node is used and the private key file should be kept secret per-node to avoid spoofing, it is not recommended to use this feature this way though. .IP "rekey = seconds" 4 .IX Item "rekey = seconds" Sets the rekeying interval in seconds (default: \f(CW3607\fR). Connections are reestablished every \f(CW\*(C`rekey\*(C'\fR seconds, making them use a new encryption key. .IP "seed-device = path" 4 .IX Item "seed-device = path" The random device used to initially and regularly seed the random number generator (default: \fI/dev/urandom\fR). Randomness is of paramount importance to the security of the algorithms used in gvpe. .Sp On program start and every seed-interval, gvpe will read 64 octets. .Sp Setting this path to the empty string will disable this functionality completely (the underlying crypto library will likely look for entropy sources on it's own though, so not all is lost). .IP "seed-interval = seconds" 4 .IX Item "seed-interval = seconds" The number of seconds between reseeds of the random number generator (default: \f(CW3613\fR). A value of \f(CW0\fR disables this regular reseeding. .IP "serial = string" 4 .IX Item "serial = string" The configuration serial number. This can be any string up to 16 bytes length. Only when the serial matches on both sides of a connection will the connection succeed. This is \fInot\fR a security mechanism and eay to spoof, this mechanism exists to alert users that their config is outdated. .Sp It's recommended to specify this is a date string such as \f(CW\*(C`2013\-05\-05\*(C'\fR or \&\f(CW20121205084417\fR. .Sp The exact algorithm is as this: if a connection request is received form a node with an identical serial, then it succeeds normally. .Sp If the remote serial is lower than the local serial, it is ignored. .Sp If the remote serial is higher than the local serial, a warning message is logged. .SS "\s-1NODE SPECIFIC SETTINGS\s0" .IX Subsection "NODE SPECIFIC SETTINGS" The following settings are node-specific, that is, every node can have different settings, even within the same gvpe instance. Settings that are set before the first node section set the defaults, settings that are set within a node section only apply to the given node. .IP "allow-direct = nodename" 4 .IX Item "allow-direct = nodename" Allow direct connections to this node. See \f(CW\*(C`deny\-direct\*(C'\fR for more info. .IP "compress = yes|true|on | no|false|off" 4 .IX Item "compress = yes|true|on | no|false|off" For the current node, this specified whether it will accept compressed packets, and for all other nodes, this specifies whether to try to compress data packets sent to this node (default: \f(CW\*(C`yes\*(C'\fR). Compression is really cheap even on slow computers, has no size overhead at all and will only be used when the other side supports compression, so enabling this is often a good idea. .IP "connect = ondemand | never | always | disabled" 4 .IX Item "connect = ondemand | never | always | disabled" Sets the connect mode (default: \f(CW\*(C`always\*(C'\fR). It can be \f(CW\*(C`always\*(C'\fR (always try to establish and keep a connection to the given node), \f(CW\*(C`never\*(C'\fR (never initiate a connection to the given host, but accept connections), \&\f(CW\*(C`ondemand\*(C'\fR (try to establish a connection when there are outstanding packets in the queue and take it down after the keepalive interval) or \&\f(CW\*(C`disabled\*(C'\fR (node is bad, don't talk to it). .Sp Routers will automatically be forced to \f(CW\*(C`always\*(C'\fR unless they are \&\f(CW\*(C`disabled\*(C'\fR, to ensure all nodes can talk to each other. .IP "deny-direct = nodename | *" 4 .IX Item "deny-direct = nodename | *" Deny direct connections to the specified node (or all nodes when \f(CW\*(C`*\*(C'\fR is given). Only one node can be specified, but you can use multiple \&\f(CW\*(C`allow\-direct\*(C'\fR and \f(CW\*(C`deny\-direct\*(C'\fR statements. This only makes sense in networks with routers, as routers are required for indirect connections. .Sp Sometimes, a node cannot reach some other nodes for reasons of network connectivity. For example, a node behind a firewall that only allows connections to/from a single other node in the network. In this case one should specify \f(CW\*(C`deny\-direct = *\*(C'\fR and \f(CW\*(C`allow\-direct = othernodename\*(C'\fR (the other node \fImust\fR be a router for this to work). .Sp The algorithm to check whether a connection may be direct is as follows: .Sp 1. Other node mentioned in an \f(CW\*(C`allow\-direct\*(C'\fR? If yes, allow the connection. .Sp 2. Other node mentioned in a \f(CW\*(C`deny\-direct\*(C'\fR? If yes, deny direct connections. .Sp 3. Allow the connection. .Sp That is, \f(CW\*(C`allow\-direct\*(C'\fR takes precedence over \f(CW\*(C`deny\-direct\*(C'\fR. .Sp The check is done in both directions, i.e. both nodes must allow a direct connection before one is attempted, so you only need to specify connect limitations on one node. .IP "dns-domain = domain-suffix" 4 .IX Item "dns-domain = domain-suffix" The \s-1DNS\s0 domain suffix that points to the \s-1DNS\s0 tunnel server for this node. .Sp The domain must point to a \s-1NS\s0 record that points to the \fIdns-hostname\fR, i.e. .Sp .Vb 2 \& dns\-domainname = tunnel.example.net \& dns\-hostname = tunnel\-server.example.net .Ve .Sp Corresponds to the following \s-1DNS\s0 entries in the \f(CW\*(C`example.net\*(C'\fR domain: .Sp .Vb 2 \& tunnel.example.net. NS tunnel\-server.example.net. \& tunnel\-server.example.net. A 13.13.13.13 .Ve .IP "dns-hostname = hostname/ip" 4 .IX Item "dns-hostname = hostname/ip" The address to bind the \s-1DNS\s0 tunnel socket to, similar to the \f(CW\*(C`hostname\*(C'\fR, but for the \s-1DNS\s0 tunnel protocol only. Default: \f(CW0.0.0.0\fR, but that might change. .IP "dns-port = port-number" 4 .IX Item "dns-port = port-number" The port to bind the \s-1DNS\s0 tunnel socket to. Must be \f(CW53\fR on \s-1DNS\s0 tunnel servers. .IP "enable-dns = yes|true|on | no|false|off" 4 .IX Item "enable-dns = yes|true|on | no|false|off" See \fIgvpe.protocol\fR\|(7) for a description of the \s-1DNS\s0 transport protocol. Avoid this protocol if you can. .Sp Enable the \s-1DNS\s0 tunneling protocol on this node, either as server or as client. Support for this transport protocol is only available when gvpe was compiled using the \f(CW\*(C`\-\-enable\-dns\*(C'\fR option. .IP "enable-icmp = yes|true|on | no|false|off" 4 .IX Item "enable-icmp = yes|true|on | no|false|off" See \fIgvpe.protocol\fR\|(7) for a description of the \s-1ICMP\s0 transport protocol. .Sp Enable the \s-1ICMP\s0 transport using \s-1ICMP\s0 packets of type \f(CW\*(C`icmp\-type\*(C'\fR on this node. .IP "enable-rawip = yes|true|on | no|false|off" 4 .IX Item "enable-rawip = yes|true|on | no|false|off" See \fIgvpe.protocol\fR\|(7) for a description of the \s-1RAW IP\s0 transport protocol. .Sp Enable the \s-1RAW\s0 IPv4 transport using the \f(CW\*(C`ip\-proto\*(C'\fR protocol (default: \f(CW\*(C`no\*(C'\fR). .IP "enable-tcp = yes|true|on | no|false|off" 4 .IX Item "enable-tcp = yes|true|on | no|false|off" See \fIgvpe.protocol\fR\|(7) for a description of the \s-1TCP\s0 transport protocol. .Sp Enable the TCPv4 transport using the \f(CW\*(C`tcp\-port\*(C'\fR port (default: \f(CW\*(C`no\*(C'\fR). Support for this transport protocol is only available when gvpe was compiled using the \f(CW\*(C`\-\-enable\-tcp\*(C'\fR option. .IP "enable-udp = yes|true|on | no|false|off" 4 .IX Item "enable-udp = yes|true|on | no|false|off" See \fIgvpe.protocol\fR\|(7) for a description of the \s-1UDP\s0 transport protocol. .Sp Enable the UDPv4 transport using the \f(CW\*(C`udp\-port\*(C'\fR port (default: \f(CW\*(C`no\*(C'\fR). .IP "hostname = hostname | ip [can not be defaulted]" 4 .IX Item "hostname = hostname | ip [can not be defaulted]" Forces the address of this node to be set to the given \s-1DNS\s0 hostname or \s-1IP\s0 address. It will be resolved before each connect request, so dyndns should work fine. If this setting is not specified and a router is available, then the router will be queried for the address of this node. Otherwise, the connection attempt will fail. .Sp Note that \s-1DNS\s0 resolving is done synchronously, pausing the daemon. If that is an issue you need to specify \s-1IP\s0 addresses. .IP "icmp-type = integer" 4 .IX Item "icmp-type = integer" Sets the type value to be used for outgoing (and incoming) packets sent via the \s-1ICMP\s0 transport. .Sp The default is \f(CW0\fR (which is \f(CW\*(C`echo\-reply\*(C'\fR, also known as \&\*(L"ping-reply\*(R"). Other useful values include \f(CW8\fR (\f(CW\*(C`echo\-request\*(C'\fR, a.k.a. \&\*(L"ping\*(R") and \f(CW11\fR (\f(CW\*(C`time\-exceeded\*(C'\fR), but any 8\-bit value can be used. .IP "if-up-data = value" 4 .IX Item "if-up-data = value" The value specified using this directive will be passed to the \f(CW\*(C`if\-up\*(C'\fR script in the environment variable \f(CW\*(C`IFUPDATA\*(C'\fR. .IP "inherit-tos = yes|true|on | no|false|off" 4 .IX Item "inherit-tos = yes|true|on | no|false|off" Whether to inherit the \s-1TOS\s0 settings of packets sent to the tunnel when sending packets to this node (default: \f(CW\*(C`yes\*(C'\fR). If set to \f(CW\*(C`yes\*(C'\fR then outgoing tunnel packets will have the same \s-1TOS\s0 setting as the packets sent to the tunnel device, which is usually what you want. .IP "low-power = yes|true|on | no|false|off" 4 .IX Item "low-power = yes|true|on | no|false|off" If true, designates a node as a low-power node. Low-power nodes use larger timeouts and try to reduce cpu time. Other nodes talking to a low-power node will also use larger timeouts, and will use less aggressive optimisations, in the hope of reducing load. Security is not compromised. .Sp The typical low-power node would be a mobile phone, where wakeups and encryption can significantly increase power drain. .IP "max-retry = positive-number" 4 .IX Item "max-retry = positive-number" The maximum interval in seconds (default: \f(CW3600\fR, one hour) between retries to establish a connection to this node. When a connection cannot be established, gvpe uses exponential back-off capped at this value. It's sometimes useful to set this to a much lower value (e.g. \f(CW120\fR) on connections to routers that usually are stable but sometimes are down, to assure quick reconnections even after longer downtimes. .IP "max-ttl = seconds" 4 .IX Item "max-ttl = seconds" Expire packets that couldn't be sent after this many seconds (default: \f(CW60\fR). Gvpe will normally queue packets for a node without an active connection, in the hope of establishing a connection soon. This value specifies the maximum lifetime a packet will stay in the queue, if a packet gets older, it will be thrown away. .IP "max-queue = positive\-number>=1" 4 .IX Item "max-queue = positive-number>=1" The maximum number of packets that will be queued (default: \f(CW512\fR) for this node. If more packets are sent then earlier packets will be expired. See \f(CW\*(C`max\-ttl\*(C'\fR, above. .IP "router-priority = 0 | 1 | positive\-number>=2" 4 .IX Item "router-priority = 0 | 1 | positive-number>=2" Sets the router priority of the given node (default: \f(CW0\fR, disabled). .Sp If some node tries to connect to another node but it doesn't have a hostname, it asks a router node for it's \s-1IP\s0 address. The router node chosen is the one with the highest priority larger than \f(CW1\fR that is currently reachable. This is called a \fImediated\fR connection, as the connection itself will still be direct, but it uses another node to mediate between the two nodes. .Sp The value \f(CW0\fR disables routing, that means if the node receives a packet not for itself it will not forward it but instead drop it. .Sp The special value \f(CW1\fR allows other hosts to route through the router host, but they will never route through it by default (i.e. the config file of another node needs to specify a router priority higher than one to choose such a node for routing). .Sp The idea behind this is that some hosts can, if required, bump the \&\f(CW\*(C`router\-priority\*(C'\fR setting to higher than \f(CW1\fR in their local config to route through specific hosts. If \f(CW\*(C`router\-priority\*(C'\fR is \f(CW0\fR, then routing will be refused, so \f(CW1\fR serves as a \*(L"enable, but do not use by default\*(R" switch. .Sp Nodes with \f(CW\*(C`router\-priority\*(C'\fR set to \f(CW2\fR or higher will always be forced to \f(CW\*(C`connect\*(C'\fR = \f(CW\*(C`always\*(C'\fR (unless they are \f(CW\*(C`disabled\*(C'\fR). .IP "tcp-port = port-number" 4 .IX Item "tcp-port = port-number" Similar to \f(CW\*(C`udp\-port\*(C'\fR (default: \f(CW655\fR), but sets the \s-1TCP\s0 port number. .IP "udp-port = port-number" 4 .IX Item "udp-port = port-number" Sets the port number used by the \s-1UDP\s0 protocol (default: \f(CW655\fR, not officially assigned by \s-1IANA\s0!). .SH "CONFIG DIRECTORY LAYOUT" .IX Header "CONFIG DIRECTORY LAYOUT" The default (or recommended) directory layout for the config directory is: .IP "gvpe.conf" 4 .IX Item "gvpe.conf" The config file. .IP "if-up" 4 .IX Item "if-up" The if-up script .IP "node-up, node-down" 4 .IX Item "node-up, node-down" If used the node up or node-down scripts. .IP "hostkey" 4 .IX Item "hostkey" The (default path of the) private key of the current host. .IP "pubkey/nodename" 4 .IX Item "pubkey/nodename" The public keys of the other nodes, one file per node. .SH "SEE ALSO" .IX Header "SEE ALSO" \&\fIgvpe\fR\|(5), \fIgvpe\fR\|(8), \fIgvpectrl\fR\|(8). .SH "AUTHOR" .IX Header "AUTHOR" Marc Lehmann