.TH SMP_REP_MANUFACTURER "8" "May 2011" "smp_utils\-0.96" SMP_UTILS .SH NAME smp_rep_manufacturer \- invoke REPORT MANUFACTURER INFORMATION SMP function .SH SYNOPSIS .B smp_rep_manufacturer [\fI\-\-help\fR] [\fI\-\-hex\fR] [\fI\-\-interface=PARAMS\fR] [\fI\-\-raw\fR] [\fI\-\-sa=SAS_ADDR\fR] [\fI\-\-verbose\fR] [\fI\-\-version\fR] [\fI\-\-zero\fR] \fISMP_DEVICE[,N]\fR .SH DESCRIPTION .\" Add any additional description here .PP Sends a SAS Serial Management Protocol (SMP) REPORT MANUFACTURER INFORMATION function request to an SMP target. The SMP target is identified by the \fISMP_DEVICE\fR and the \fISAS_ADDR\fR. Depending on the interface, the \fISAS_ADDR\fR may be deduced from the \fISMP_DEVICE\fR. The mpt interface uses \fISMP_DEVICE\fR to identify a HBA (an SMP initiator) and needs the additional \fI,N\fR to differentiate between HBAs if there are multiple present. .SH OPTIONS Mandatory arguments to long options are mandatory for short options as well. .TP \fB\-h\fR, \fB\-\-help\fR output the usage message then exit. .TP \fB\-H\fR, \fB\-\-hex\fR output the response (less the CRC field) in hexadecimal. .TP \fB\-I\fR, \fB\-\-interface\fR=\fIPARAMS\fR interface specific parameters. In this case "interface" refers to the path through the operating system to the SMP initiator. See the smp_utils man page for more information. .TP \fB\-r\fR, \fB\-\-raw\fR send the response (less the CRC field) to stdout in binary. All error messages are sent to stderr. .TP \fB\-s\fR, \fB\-\-sa\fR=\fISAS_ADDR\fR specifies the SAS address of the SMP target device. Typically this is an expander. This option may not be needed if the \fISMP_DEVICE\fR has the target's SAS address within it. The \fISAS_ADDR\fR is in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either prefix it with '0x' or put a trailing 'h' on it. .TP \fB\-v\fR, \fB\-\-verbose\fR increase the verbosity of the output. Can be used multiple times .TP \fB\-V\fR, \fB\-\-version\fR print the version string and then exit. .TP \fB\-z\fR, \fB\-\-zero\fR zero the Allocated Response Length field in the request. This is required for strict SAS\-1.1 compliance. However this option should not be given in SAS\-2 and later; if it is given an abridged response may result. .SH CONFORMING TO The SMP REPORT MANUFACTURER function was introduced in SAS\-1, with small additions in SAS\-1.1 . This function remains unaltered in SAS\-2 and SPL\-1. .SH AUTHORS Written by Douglas Gilbert. .SH "REPORTING BUGS" Report bugs to . .SH COPYRIGHT Copyright \(co 2006\-2011 Douglas Gilbert .br This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. .SH "SEE ALSO" .B smp_utils, smp_discover(smp_utils)