prelude-manager(1) | General Commands Manual | prelude-manager(1) |
NAME¶
prelude-manager - Collects and normalize events.
SYNOPSIS¶
prelude-manager [options]
DESCRIPTION¶
Prelude Manager is a high-availability server which can collect, filter, relay, reverse-relay, normalize and store events. Events can come from registered analyzers and/or managers. The common usage is to store nomalized events into a database, thus this can be extended to store information in plain text or xml files.
OPTIONS¶
Some prelude-manager option are contextual, they have to be prefixed by another.
--prelude Prelude generic options
--profile=<name> Profile to use for this analyzer
--heartbeat-interval=<interval> Number of seconds between two heartbeat
--server-addr=<address> Address where this sensor should report to (addr:port)
--analyzer-name=<name> Name for this analyzer
- --db=<INAME>
- Options for the libpreludedb plugin
-t, --type=<type> Type of database (mysql/pgsql/sqlite3)
-l, --log=<file name> Log all queries in a file, should be only used for debugging purpose
-h, --host=<address> The host where the database server is running (in case of client/server database)
-f, --file=<file name> The file where the database is stored (in case of file based database)
-p, --port=<port number> The port where the database server is listening (in case of client/server database)
-d, --name=<name> The name of the database where the alerts will be stored
-u, --user=<user> User of the database (in case of client/server database)
-P, --pass=<password> Password for the user (in case of client/server database)
- --debug=<INAME>
- Option for the debug plugin
-o, --object=<name> Name of IDMEF object to print (no object provided will print the entire message)
-l, --logfile=<file name> Specify output file to use (default to stdout)
- --relaying=<INAME>
- Relaying plugin option
-p, --parent-managers=<address> List of managers address:port pair where messages should be sent to
- --textmod=<INAME>
- Option for the textmod plugin
-l, --logfile=<file name> Specify logfile to use
- --xmlmod=<INAME>
- Option for the xmlmod plugin
-l, --logfile=<file name> Specify output file to use
-v, --validate=<xml> Validate IDMEF XML output against DTD
-f, --format=<format> Format XML output so that it is readable
-d, --disable-buffering=<boolean> Disable output file buffering to prevent truncated tags
--idmef-criteria-filter=<INAME> Filter message based on IDMEF criteria
-r, --rule=<rule> Filter rule, or filename containing rule
--hook=<value> Where the filter should be hooked (reporting|reverse-relaying|plugin name)
- --config=<file name>
- Configuration file to use
- -v, --version
- Print version number
- -D, --debug-level=<level>
- Run in debug mode
- -d, --daemon
- Run in daemon mode
- -P, --pidfile=<file name>
- Write Prelude PID to pidfile
- -c, --child-managers=<address>
- List of managers address:port pair where messages should be gathered from
- -l, --listen=<address>
- Address the sensors server should listen on (addr:port)
- -f, --failover=<boolean>
- Enable failover for specified report plugin
- -h, --help
- Print help
FILES¶
/etc/prelude/prelude-manager.conf - the configuration file
BUGS¶
This man page hadn't been proof-read yet.
SEE ALSO¶
prelude-adduser(1)