Scroll to navigation

EUWATCH-DESCRIBE-ALARMS(1) User Commands EUWATCH-DESCRIBE-ALARMS(1)

NAME

euwatch-describe-alarms - Describe alarms

SYNOPSIS

euwatch-describe-alarms [--action-prefix PREFIX]

[--alarm-name-prefix PREFIX] [--show-long]
[--state-value {OK,ALARM,INSUFFICIENT_DATA}] [--show-empty-fields] [-U URL] [--region USER@REGION] [-I KEY_ID] [-S KEY] [--security-token TOKEN] [--debug] [--debugger] [--version] [-h] [ALARM [ALARM ...]]

DESCRIPTION

Describe alarms

positional arguments:

limit results to specific alarms

optional arguments:

limit results to alarms whose actions' ARNs begin with a specific string
limit results to alarms whose names begin with a specific string
show all of the alarms' info
limit results to alarms in a specific state
show empty values as "(nil)"
instance monitoring service endpoint URL
region and/or user names to search when looking up config file data

-I KEY_ID, --access-key-id KEY_ID

-S KEY, --secret-key KEY

--security-token TOKEN

show debugging output
launch interactive debugger on error
show the program's version and exit
show this help message and exit
March 2016 euca2ools 3.3