Scroll to navigation

DLT-LOGSTORAGE-CTRL(1) DLT-LOGSTORAGE-CTRL(1)

NAME

dlt-logstorage-ctrl - Trigger DLT Daemon to start/stop using an offline logstorage device

SYNOPSIS

dlt-logstorage-ctrl [-h] [-c ctype] [-p path] [-e ecu] [-p<prop>] [-t timeout] [-v]

DESCRIPTION

Send a trigger to DLT Daemon to connect/disconnect a certain offline logstorage device

OPTIONS

Display a short help text.
Specify connection type: connect = 1, disconnect = 0.
Run as daemon: prop = use proprietary handler
Mount point path.
Specify the ECU ID. Default is: ECU1.
Specify connection timeout. Default is: 10s.

EXAMPLES

Activate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 1 -p /mnt/dltlog

Deactivate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 0 -p /mnt/dltlog

Run logstorage control application as daemon listen to udev events dlt-logstorage-ctrl -d

EXIT STATUS

Non zero is returned in case of failure.

AUTHOR

Christoph Lipka (clipka (at) jp.adit-jv (dot) com), Syed Hameed (shameed (at) jp.adit-jv (dot) com)

COPYRIGHT

Copyright (C) 2015 Advanced Driver Information Technology, Bosch and DENSO. License MPL-2.0: Mozilla Public License version 2.0 <http://mozilla.org/MPL/2.0/>.

BUGS

See Github issue: <https://github.com/GENIVI/dlt-daemon/issues>