'\" '\" Copyright (c) 2003-2004 Paul H Alfille, MD '\" (paul.alfille@gmail.com) '\" '\" Device manual page for the OWFS -- 1-wire filesystem package '\" Based on Dallas Semiconductor, Inc's datasheets, and trial and error. '\" '\" Free for all use. No warranty. None. Use at your own risk. '\" $Id$ '\" .TH EDS00xx 3 2003 "OWFS Manpage" "One-Wire File System" .SH NAME EDS \- Embedded Data Systems Sensors .TP .B EDS0064 \- Temperature .TP .B EDS0065 \- Temperature and Humidity .TP .B EDS0066 \- Temperature and Barometric Pressure .TP .B EDS0067 \- Temperature and Light .TP .B EDS0068 \- Temperature, Barometric Pressure and Light .TP .B EDS0070 \- Vibration .TP .B EDS0071 \- RTD 4-wire temperature .TP .B EDS0072 \- RTD 3-wire temperature .TP .B EDS0080 \- 8 Channel Analog Current Input .TP .B EDS0082 \- 8 Channel Analog Voltage Input .TP .B EDS0083 \- 4 Channel Analog Current Input .TP .B EDS0085 \- 4 Channel Analog Voltage Input .TP .B EDS0090 \- 8 Discrete I/O .SH SYNOPSIS .B Embedded Data Systems microprocessor-based sensors .SS Sub-type ( all ) .B 7E [.]XXXXXXXXXXXX[XX][/[ .B device_id | .B device_type | .B tag ]] .SS Memory ( all ) .B 7E [.]XXXXXXXXXXXX[XX][/[ .B memory | .B pages/page.[0-2|ALL] ]] .SS Standard ( all ) .B 7E [.]XXXXXXXXXXXX[XX][/[ .B '\" '\" Copyright (c) 2003-2004 Paul H Alfille, MD '\" (paul.alfille@gmail.com) '\" '\" Program manual page for the OWFS -- 1-wire filesystem package '\" Based on Dallas Semiconductor, Inc's datasheets, and trial and error. '\" '\" Free for all use. No warranty. None. Use at your own risk. '\" $Id$ '\" .B address | .B crc8 | .B id | .B locator | .B r_address | .B r_id | .B r_locator | .B type ]] .SS Temperature ( EDS0064/5/6/7/8 ) .B 7E.XXXXXXXXXXXX/EDS006X [/[ .B temperature | .B counters/seconds | .B alarm/temp_[hi|low] | .B alarm/clear | .B set_alarm/temp_[hi|low] | .B threshold/temp_[hi|low] ]] .SS Humidity ( EDS0065/8 ) .B 7E.XXXXXXXXXXXX/EDS006X [/[ .B humidity | .B humidex | .B dew_point | .B heat_index | .B alarm/humidity_[hi|low] | .B alarm/humidex_[hi|low] | .B alarm/dew_point_[hi|low] | .B alarm/heat_index_[hi|low] | .B alarm/clear | .B set_alarm/humidity_[hi|low] | .B set_alarm/humidex_[hi|low] | .B set_alarm/dew_point_[hi|low] | .B set_alarm/heat_index_[hi|low] | .B threshold/humidity_[hi|low] | .br .B threshold/humidex_[hi|low] | .B threshold/dew_point_[hi|low] | .B threshold/heat_index_[hi|low] ]] .SS Barometric Pressure ( EDS0066/8 ) .B 7E.XXXXXXXXXXXX/EDS006X [/[ .B pressure | .B inHg | .B alarm/pressure_[hi|low] | .B alarm/inHg_[hi|low] | .B alarm/clear | .B set_alarm/pressure_[hi|low] | .B set_alarm/inHg_[hi|low] | .B threshold/pressure_[hi|low] | .B threshold/inHg_[hi|low] ]] .SS Light ( EDS0067/8 ) .B 7E.XXXXXXXXXXXX/EDS006X [/[ .B light | .B alarm/light_[hi|low] | .B alarm/clear | .B set_alarm/light_[hi|low] | .B threshold/light_[hi|low] ]] .SS Vibration ( EDS0070 ) .B 7E.XXXXXXXXXXXX/EDS0070 [/[ .B vib_level | .B vib_peak | .B vib_min | .B vib_max | .B counter/seconds | .B alarm/vib_[hi|low] | .B alarm/clear | .B set_alarm/vib_[hi|low] | .B threshold/vib_[hi|low] ]] .SS RTD Temperature ( EDS0071/2 ) .B 7E.XXXXXXXXXXXX/EDS007X [/[ .B temperature | .B resistance | .B raw | .B delay | .B user_byte | .B calibration/[key|constant] | .B counter/[seconds|samples] | .B alarm/temp_[hi|low] | .B alarm/RTD_[hi_low] | .B alarm/clear | .B set_alarm/temp_[hi|low] | .B set_alarm/RTD_[hi_low] | .B threshold/temp_[hi|low] | .B threshold/RTD_[hi_low] ]] .SS Analog Current ( EDS0080 [0-7] EDS0083 [0-3] ) .B 7E.XXXXXXXXXXXX/EDS0080 [/[ .B current.[0-7|ALL] | .B max_current.[0-7|ALL] | .B min_current.[0-7|ALL] | .B threshold/current_hi.[0-7|ALL] | .B threshold/current_low.[0-7|ALL] | .B alarm/current_hi.[0-7|ALL|BYTE] | .B alarm/current_low.[0-7|ALL|BYTE] | .B set_alarm/current_hi.[0-7|ALL|BYTE] | .B set_alarm/current_low.[0-7|ALL|BYTE] | .B counter/seconds | .B memory | .B pages/page.[0-4|ALL] .SS Analog Voltage ( EDS0082 [0-7] EDS0085 [0-3] ) .B 7E.XXXXXXXXXXXX/EDS0082 [/[ .B volts.[0-7|ALL] | .B max_volts.[0-7|ALL] | .B min_volts.[0-7|ALL] | .B threshold/volts_hi.[0-7|ALL] | .B threshold/volts_low.[0-7|ALL] | .B alarm/volts_hi.[0-7|ALL|BYTE] | .B alarm/volts_low.[0-7|ALL|BYTE] | .B set_alarm/volts_hi.[0-7|ALL|BYTE] | .B set_alarm/volts_low.[0-7|ALL|BYTE] | .B counter/seconds | .B memory | .B pages/page.[0-4|ALL] .SS I/O ( EDS0090 ) .B 7E.XXXXXXXXXXXX/EDS009X [/[ .B input.[0-7|ALL] | .B counter/[seconds | pulses.[0-7|ALL]|reset.[0-7|ALL|BYTE]] | .B output/[set.[0-7|ALL|BYTE]|off.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] | .B latch/[state.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] | .B alarm/[hi.[0-7|ALL]|low.[0-7|ALL]|clear] | .B set_alarm/[hi.[0-7|ALL]|low.[0-7|ALL]] .SS LED ( all ) .B 7E.XXXXXXXXXXXX/EDS00XX/LED/[state|control] .SS relay ( all ) .B 7E.XXXXXXXXXXXX/EDS00XX/relay/[state|control] .SH FAMILY CODE .TP .I 7E .SH TEMPERATURE .SS EDS006X/temperature .I read-only, floating-point .br Temperature for the EDS006X series of chips. In the \-55C to 125C range, with 0.0636C precision. The temperature is read every second, continually. Data is presented in the specified temperature scale, Celsius by default. .SS EDS007X/temperature .I read-only, floating-point .br Temperature for the EDS007X series of chips. Read using a wide-range precise RTD sensor. Typical range is \-60C to 260C with 0.15C accuracy, although a range of \-200C to 850C is possible. The temperature is read every second unless a longer .I EDS007X/delay is given. Data is presented in the specified temperature scale, Celsius by default. .SS EDS007X/resistance .I read-only, floating-point .br Actual measured resistance (Ohms) of the RTD element. Useful if the RTD element doesn't conform to the typical European IEC 60751 standard. .SH HUMIDITY .SS EDS006X/humidity .I read-only, floating-point .br Relative humidity in the 0-100 range (percent). Read every 0.2 seconds. .SS EDS006X/dew_point .I read-only, floating-point .br Dew point computed from .I EDS006X/temperature and .I EDS006X/humidity computered every 0.2 seconds. Data is a calculated temperature and is reported in the specified temperature scale. Default Celsius. .SS EDS006X/heat_index .I read-only, floating-point .br Heat index computed from .I EDS006X/temperature and .I EDS006X/humidity computered every 0.2 seconds. Data is a calculated temperature and is reported in the specified temperature scale. Default Celsius. .SS EDS006X/humidex .I read-only, floating-point .br Humidex (popular in Canada) computed from .I EDS006X/temperature and .I EDS006X/humidity computed every 0.2 seconds. Data is a percent and reported in the 0-100 range. .SH LIGHT .SS EDS006X/light .I read-only, unsigned integer .br Ambient light in Lux. Measured every 0.2 seconds. .SH PRESSURE .SS EDS006X/pressure .I read-only, floating-point .br Ambient pressure, measured every 0.2 seconds. Data in the selected pressure scale (default mBar). .SS EDS006X/inHg .I read-only, floating-point .br Ambient pressure, measured every 0.2 seconds. Data in the inHg scale. .SH VIBRATION .SS EDS0070/vib_level .I read_only, unsigned integer .br Vibration registered by sensor (instantaneous value) in 0-1023 range. .SS EDS0070/vib_peak .I read_only, unsigned integer .br Vibration registered by sensor (highest recent value -- slowly decays) in 0-1023 range. .SS EDS0070/vib_min .I read_only, unsigned integer .br Vibration registered by sensor (lowest value) in 0-1023 range. .SS EDS0070/vib_max .I read_only, unsigned integer .br Vibration registered by sensor (highest value) in 0-1023 range. .SH CURRENT The .B EDS0080 and .B EDS0083 measure current in the 4-20mA range, with upper and threshold limits and the ability to set an alarm and independently trigger a relay if the value is out of range. .SS EDS0080/current.[0-7|ALL] EDS0083/current.[0-3|ALL] .I read-only, floating point .br Current current level. (4-20mA) .SS EDS0080/max_current.[0-7|ALL] EDS0080/max_current.[0-3|ALL] .SS EDS0083/min_current.[0-7|ALL] EDS0083/min_current.[0-3|ALL] .I read-only, floating point .br Maximum and minimum current readings since last .I alarm/clear command. .SH VOLTAGE The .B EDS0082 and .B EDS0085 measure voltage in the 0-10V range, with upper and threshold limits and the ability to set an alarm and independently trigger a relay if the value is out of range. .SS EDS0082/volts.[0-7|ALL] EDS0085/volts.[0-3|ALL] .I read-only, floating point .br Current voltage level. (0-10V) .SS EDS0082/max_volts.[0-7|ALL] EDS0085/max_volts.[0-3|ALL] .SS EDS0082/min_volts.[0-7|ALL] EDS0085/min_volts.[0-3|ALL] .I read-only, floating point .br Maximum and minimum voltage readings since last .I alarm/clear command. .SH THRESHOLD High and low range of acceptable sensor readings. Values outside this range will trigger an alarm if the corresponding .I EDS00XX/set_alarm flag is set. .SS EDS00XX/threshold/temp_hi EDS00XX/threshold/temp_low .I read-write, floating-point .br Threshold temperatures in the specified temperature scale. Default Celsius. .SS EDS006X/threshold/humidity_hi EDS006X/threshold/humidity_low .SS EDS006X/threshold/dew_point_hi EDS006X/threshold/dew_point_low .SS EDS006X/threshold/heat_index_hi EDS006X/threshold/heat_index_low .SS EDS006X/threshold/humidex_hi tEDS006X/threshold/humidex_low .I read-write, floating-point .br Threshold humidity values. .I Dew point and .I Heat index are in the specified temperature scale. Default Celsius. .SS EDS006X/threshold/pressure_hi EDS006X/threshold/pressure_low .SS EDS006X/threshold/inHg_hi EDS006X/threshold/inHg_low .I read-write, floating-point .br Threshold barometric pressure values. .I Pressure is the specified pressure scale. Default mBar. .SS EDS006X/threshold/light_hi EDS006X/threshold/light_low .I read-write, unsigned .br Threshold light (lux) values. .SS EDS0070/threshold/vib_hi EDS0070/threshold/vib_low .I read-write, unsigned .br Vibration sensor alarm limits in 0-1023 range. .SS EDS007X/threshold/resistance_hi EDS007X/threshold/resistance_low .I read-write, floating-point .br Threshold RTD resistance values (Ohm). .SS EDS0080/threshold/current_hi.[0-7|ALL] EDS0080/threshold/current_low.[0-7|ALL] .SS EDS0082/threshold/volts_hi.[0-7|ALL] EDS0082/threshold/volts_low.[0-7|ALL] .SS EDS0083/threshold/current_hi.[0-3|ALL EDS0083/threshold/current_low.[0-3|ALL] .SS EDS0085/threshold/volts_hi.[0-3|ALL] EDS0085/threshold/volts_low.[0-3|ALL|] .I read-write, floating-point .br Voltage or current threshold limits .SH SET ALARM Set conditional alarm to trigger if corresponding flag is set. Also must set high and low .I threshold. .SS EDS00XX/set_alarm/temp_hi EDS00XX/set_alarm/temp_low .SS EDS006X/set_alarm/humidity_hi EDS006X/set_alarm/humidity_low .SS EDS006X/set_alarm/dew_point_hi EDS006X/set_alarm/dew_point_low .SS EDS006X/set_alarm/heat_index_hi EDS006X/set_alarm/heat_index_low .SS EDS006X/set_alarm/humidex_hi EDS006X/set_alarm/humidex_low .SS EDS006X/set_alarm/pressure_hi EDS006X/set_alarm/pressure_low .SS EDS006X/set_alarm/inHg_hi EDS006X/set_alarm/inHg_low .SS EDS006X/set_alarm/light_hi EDS006X/set_alarm/light_low .SS EDS0070/set_alarm/vib_hi EDS0070/set_alarm/vib_low .SS EDS007X/set_alarm/resistance_hi EDS007X/set_alarm/resistance_low .SS EDS0080/set_alarm/current_hi.[0-7|ALL|BYTE] .SS EDS0080/set_alarm/current_low.[0-7|ALL|BYTE] .SS EDS0082/set_alarm/volts_hi.[0-7|ALL|BYTE] .SS EDS0082/set_alarm/volts_low.[0-7|ALL|BYTE] .SS EDS0083/set_alarm/current_hi.[0-3|ALL|BYTE] .SS EDS0083/set_alarm/current_low.[0-3|ALL|BYTE] .SS EDS0085/set_alarm/volts_hi.[0-3|ALL|BYTE] .SS EDS0085/set_alarm/volts_low.[0-3|ALL|BYTE] .I read-write, yes-no .br Flag to set corresponding out-of-range alarm. "1" turns on flag, and "0" turns off. .SH ALARM Show or clear the out-of-range flags. When set, the device will respond to a conditional search. Clearing the flags is performed with the .I EDS00XX/alarm/clear command, not just having the measured value return to the center range. .SS EDS00XX/alarm/clear .I write-only, yes-no .br Write "1" to clear .B ALL the alarm flags. .SS EDS00XX/alarm/temp_hi EDS00XX/alarm/temp_low .SS EDS006X/alarm/humidity_hi EDS006X/alarm/humidity_low .SS EDS006X/alarm/dew_point_hi EDS006X/alarm/dew_point_low .SS EDS006X/alarm/heat_index_hi EDS006X/alarm/heat_index_low .SS EDS006X/alarm/humidex_hi EDS006X/alarm/humidex_low .SS EDS006X/alarm/pressure_hi EDS006X/alarm/pressure_low .SS EDS006X/alarm/inHg_hi EDS006X/alarm/inHg_low .SS EDS006X/alarm/light_hi EDS006X/alarm/light_low .SS EDS0070/alarm/vib_hi EDS007X/alarm/vib_low .SS EDS007X/alarm/resistance_hi EDS007X/alarm/resistance_low .SS EDS0080/alarm/current_hi.[0-7|ALL|BYTE] .SS EDS0080/alarm/current_low.[0-7|ALL|BYTE] .SS EDS0082/alarm/volts_hi.[0-7|ALL|BYTE] .SS EDS0082/alarm/volts_low.[0-7|ALL|BYTE] .SS EDS0083/alarm/current_hi.[0-3|ALL|BYTE] .SS EDS0083/alarm/current_low.[0-3|ALL|BYTE] .SS EDS0085/alarm/volts_hi.[0-3|ALL|BYTE] .SS EDS0085/alarm/volts_low.[0-3|ALL|BYTE] .SS EDS0090/alarm/hi[0-7|ALL] EDS0090/alarm/low[0-7|ALL] .I read-only, yes-no .br Show corresponding out-of-range alarm. "1" means in alarm state. Can only be turned off with .I clear .SH RELAY Optionally found on the EDS006X and EDS007X. Can be controlled by software or the alarm condition. .SS EDS00XX/relay/control .I read-write, unsigned .br Set the relay control scheme: .TP 0 alarm control with hysteresis .TP 1 alarm control but need .I EDS00XX/alarm/clear to unset .TP 2 Control with .I EDS00XX/relay/state .TP 3 Always off .SS EDS00XX/relay/state .I read-write, yes-no .br Turn the relay on or off if the .I EDS00XX/relay/control is set to "2" .SH LED light Found on the EDS006X and EDS007X. Can be controlled by software or the alarm condition. .SS EDS00XX/LED/control .I read-write, unsigned .br Set the LED control scheme: .TP 0 alarm control with hysteresis .TP 1 alarm control but need .I EDS00XX/alarm/clear to unset .TP 2 Control with .I EDS00XX/LED/state .TP 3 Always off .SS EDS00XX/LED/state .I read-write, yes-no .br Turn the LED on or off if the .I EDS00XX/LED/control is set to "2" .SH COUNTER .SS EDS00XX/counter/seconds .I read-only, unsigned integer .br Approximate seconds since power up. .SS EDS0090/counter/pulses.0-7 | ALL .I read-only, unsigned integer .br Pulses on each channel since power up or reset. Channel should be set to input ( .I EDS0090/output/set.x =0 ) .SS EDS0090/counter/reset.0-7 | ALL | BYTE .I read-write, yes-no .br Clear the pulse count on the corresponding channel. .SS EDS007X/counter/samples .I read-only, unsigned integer .br Approximate samples since power up. .SH MEMORY .SS memory .I read-write, binary .br 96 bytes of memory. Not all is writable. Access to .I EDS00XX functions is better accomplished through the data fields, which expose all the chip features. .SS pages/page.0 ... pages/page.2 pages/page.ALL .I read-write, binary .br Memory is split into 3 pages of 32 bytes each. Only page 2 is writable. .I ALL is an aggregate of the pages. Each page is accessed sequentially. .SS EDS008X/memory .I read-write, binary .br 160 bytes of memory. Not all is writable. Access to .I EDS008X functions is better accomplished through the data fields, which expose all the chip features. The .I EDS008X has more memory than the other chips, so a separate entry in the sudbirectory makes it available. .SS EDS008X/pages/page.0-4 EDS008X/pages/page.ALL .I read-write, binary .br Memory is split into 5 pages of 32 bytes each. Only page 5 is writable. The .I EDS008X has more memory than the other chips, so a separate entry in the sudbirectory makes the extra pages available. .I ALL is an aggregate of the pages. Each page is accessed sequentially. .SH SUB-TYPE .SS tag .I read-only, ascii .br Text description of the device. Up to 30 characters. .SS device_type .I read-only, ascii .br Device name. E.g: "EDS0071" .SS device_id .I read-only, unsigned .br Number corresponding to the hexadecimal type. E.g: .br EDS0071 -> 0x0071 -> 113 in decimal .SH STANDARD PROPERTIES '\" '\" Copyright (c) 2003-2004 Paul H Alfille, MD '\" (paul.alfille@gmail.com) '\" '\" Program manual page for the OWFS -- 1-wire filesystem package '\" Based on Dallas Semiconductor, Inc's datasheets, and trial and error. '\" '\" Free for all use. No warranty. None. Use at your own risk. '\" $Id$ '\" .SS address .SS r_address .I read-only, ascii .br The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F). .br .I address starts with the .I family code .br .I r address is the .I address in reverse order, which is often used in other applications and labeling. .SS crc8 .I read-only, ascii .br The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexadecimal digits (0-9A-F). .SS family .I read-only, ascii .br The 8-bit family code. Unique to each .I type of device. Given as upper case hexadecimal digits (0-9A-F). .SS id .SS r_id .I read-only, ascii .br The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexadecimal digits (0-9A-F). .br .I r id is the .I id in reverse order, which is often used in other applications and labeling. .SS locator .SS r_locator .I read-only, ascii .br Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a .B Link Locator the .I locator will show a unique 8-byte number (16 character hexadecimal) starting with family code FE. .br If no .B Link Locator is between the device and the master, the .I locator field will be all FF. .br .I r locator is the .I locator in reverse order. .SS present (DEPRECATED) .I read-only, yes-no .br Is the device currently .I present on the 1-wire bus? .SS type .I read-only, ascii .br Part name assigned by Dallas Semi. E.g. .I DS2401 Alternative packaging (iButton vs chip) will not be distiguished. .SH ALARMS None. .SH DESCRIPTION '\" '\" Copyright (c) 2003-2004 Paul H Alfille, MD '\" (paul.alfille@gmail.com) '\" '\" Program manual page for the OWFS -- 1-wire filesystem package '\" Based on Dallas Semiconductor, Inc's datasheets, and trial and error. '\" '\" Free for all use. No warranty. None. Use at your own risk. '\" $Id$ '\" .SS 1-Wire .I 1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power. .PP Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included. .PP The 1-wire scheme uses a single .I bus master and multiple .I slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID. .PP Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters. .SS OWFS design .I OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written. .PP Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed. .SS EDS00XX Overview The EDS00XX sensors are a family of devices from .I Embedded Data Systems. Although provisional support for several types is included, only early .I EDS0071 has been tested with .I OWFS. .PP The sensors all share the same .I 7E family code. They have the same first memory page layout with a text .I tag property that describes them, and a .I sub-type field giving the particular sensor. The data properties shown in a directory listing will be specific to the sensor .I sub-type. .SS EDS0071 The .B EDS0071 (3) is a micro-processor based 1-wire slave made by EDS (Embedded Data Systams). Is uses a high accuracy and extended range RTD sensor to accurately measure temperatures. .SS Memory The .I EDS00XX sensors are read and controlled by accessing parts of their on-chip memory. Although the raw memory contents are exposed in the .I memory and .I pages fields, all the available functionality is best accessed by the other fields. In fact, directly changing memory will confuse .I OWFS. .SS Relay and LED All the .I EDS00XX sensors have an LED and optional relay. Both can be controlled either directly, or when the sensors reaches an alarm state. .SH ADDRESSING '\" '\" Copyright (c) 2003-2004 Paul H Alfille, MD '\" (paul.alfille@gmail.com) '\" '\" Program manual page for the OWFS -- 1-wire filesystem package '\" Based on Dallas Semiconductor, Inc's datasheets, and trial and error. '\" '\" Free for all use. No warranty. None. Use at your own risk. '\" $Id$ '\" All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form: .TP .B Family Code 8 bits .TP .B Address 48 bits .TP .B CRC 8 bits .IP .PP Addressing under OWFS is in hexadecimal, of form: .IP .B 01.123456789ABC .PP where .B 01 is an example 8-bit family code, and .B 12345678ABC is an example 48 bit address. .PP The dot is optional, and the CRC code can included. If included, it must be correct. .SH DATASHEET .TP .B EDS0064 EDS0065 EDS0066 EDS0067 EDS0068 https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vN2E4NGUwMGItMzc5MS00NDNmLTljZGYtN2NmM2Q3YWE5NmVh&hl=en .TP .B EDS0070 http://www.embeddeddatasystems.com/assets/images/supportFiles/manuals/EN-UserMan%20%20OW-Vibration%20V01.pdf .TP .B EDS0071 EDS0072 https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vMjVhNWQzYzItZTRhMi00NGY2LWI4NTQtYjZlYTgzYzY0NmNm&hl=en .TP .B EDS0080 EDS0083 https://eds.zendesk.com/attachments/token/ulnpj6mvpp6yzwo/?name=EN-USERMAN+OW-IO-AIX-420+v1p0.pdf .TP .B EDS0082 EDS0085 https://eds.zendesk.com/attachments/token/vyai6ylpw6edala/?name=EN-USERMAN+OW-IO-AIX-10V+v1p0.pdf .TP .B EDS0090 8 Discrete I/O .SH SEE ALSO .SS Programs .B owfs (1) owhttpd (1) owftpd (1) owserver (1) .B owdir (1) owread (1) owwrite (1) owpresent (1) .B owtap (1) .SS Configuration and testing .B owfs (5) owtap (1) owmon (1) .SS Language bindings .B owtcl (3) owperl (3) owcapi (3) .SS Clocks .B DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3) .SS ID .B DS2401 (3) DS2411 (3) DS1990A (3) .SS Memory .B DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3) .SS Switches .B DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) .SS Temperature .B DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3) .SS Humidity .B DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3) .SS Voltage .B DS2450 (3) .SS Resistance .B DS2890 (3) .SS Multifunction (current, voltage, temperature) .B DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3) .SS Counter .B DS2423 (3) .SS LCD Screen .B LCD (3) DS2408 (3) .SS Crypto .B DS1977 (3) .SS Pressure .B DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3) .SS Moisture .B EEEF (3) DS2438 (3) .SH AVAILABILITY http://www.owfs.org .SH AUTHOR Paul Alfille (paul.alfille@gmail.com)