MODBUS_RTU_GET_SERIA(3) | Libmodbus Manual | MODBUS_RTU_GET_SERIA(3) |
NAME¶
modbus_rtu_get_serial_mode - get the current serial modeSYNOPSIS¶
int modbus_rtu_get_serial_mode(modbus_t *ctx);DESCRIPTION¶
The modbus_rtu_get_serial_mode() function shall return the serial mode currently used by the libmodbus context: MODBUS_RTU_RS232the serial line is set for RS232 communication. RS-232
(Recommended Standard 232) is the traditional name for a series of standards
for serial binary single-ended data and control signals connecting between a
DTE (Data Terminal Equipment) and a DCE (Data Circuit-terminating Equipment).
It is commonly used in computer serial ports
MODBUS_RTU_RS485
the serial line is set for RS485 communication. EIA-485,
also known as TIA/EIA-485 or RS-485, is a standard defining the electrical
characteristics of drivers and receivers for use in balanced digital
multipoint systems. This standard is widely used for communications in
industrial automation because it can be used effectively over long distances
and in electrically noisy environments.
This function is only available on Linux kernels 2.6.28 onwards and can only be
used with a context using a RTU backend.
RETURN VALUE¶
The modbus_rtu_get_serial_mode() function shall return MODBUS_RTU_RS232 or MODBUS_RTU_RS485 if successful. Otherwise it shall return -1 and set errno to one of the values defined below.ERRORS¶
EINVALThe current libmodbus backend is not RTU.