MODBUS_NEW_TCP_PI(3) | Libmodbus Manual | MODBUS_NEW_TCP_PI(3) |
NAME¶
modbus_new_tcp_pi - create a libmodbus context for TCP Protocol IndependentSYNOPSIS¶
modbus_t *modbus_new_tcp_pi(const char *node, const char * service);DESCRIPTION¶
The modbus_new_tcp_pi() function shall allocate and initialize a modbus_t structure to communicate with a Modbus TCP IPv4 or Ipv6 server. The node argument specifies the host name or IP address of the host to connect to, eg. 192.168.0.5 , ::1 or server.com. The service argument is the service name/port number to connect to. To use the default Modbus port use the string "502". On many Unix systems, it’s convenient to use a port number greater than or equal to 1024 because it’s not necessary to have administrator privileges.RETURN VALUE¶
The modbus_new_tcp_pi() function shall return a pointer to a modbus_t structure if successful. Otherwise it shall return NULL and set errno to one of the values defined below.ERRORS¶
EINVALThe node string is empty or has been truncated. The
service string is empty or has been truncated.
EXAMPLE¶
modbus_t *ctx; ctx = modbus_new_tcp_pi("::1", "1502"); if (ctx == NULL) { fprintf(stderr, "Unable to allocate libmodbus context\n"); return -1; } if (modbus_connect(ctx) == -1) { fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno)); modbus_free(ctx); return -1; }
SEE ALSO¶
modbus_new_tcp(3) modbus_new_rtu(3) modbus_free(3)AUTHORS¶
The libmodbus documentation was written by Stéphane Raimbault < stephane.raimbault@gmail.com[1]>NOTES¶