NAME¶
udpclo - UDP-based BP convergence layer output task
SYNOPSIS¶
udpclo
DESCRIPTION¶
udpclo is a background "daemon" task that extracts bundles from
the queues of bundles ready for transmission via UDP to remote bundle protocol
agents, encapsulates them in UDP datagrams, and sends those datagrams to the
appropriate remote UDP sockets as indicated by the host names and UDP port
numbers (destination induct names) associated with the bundles by the routing
daemons that enqueued them.
Note that
udpclo is a "promiscuous" CLO daemon, able to
transmit bundles to any UDP destination induct. Its duct name is '*' rather
than the induct name of any single UDP destination induct to which it might be
dedicated, so scheme configuration directives that cite this outduct must
provide destination induct IDs. For the UDP convergence-layer protocol,
destination induct IDs are identical to induct names, i.e., they are of the
form
local_hostname[:
local_port_nbr].
udpclo is spawned automatically by
bpadmin in response to the 's'
(START) command that starts operation of the Bundle Protocol, and it is
terminated by
bpadmin in response to an 'x' (STOP) command.
udpclo can also be spawned and terminated in response to START and STOP
commands that pertain specifically to the UDP convergence layer protocol.
EXIT STATUS¶
- "0"
- udpclo terminated normally, for reasons noted in the ion.log
file. If this termination was not commanded, investigate and solve the
problem identified in the log file and use bpadmin to restart
udpclo.
- "1"
- udpclo terminated abnormally, for reasons noted in the
ion.log file. Investigate and solve the problem identified in the
log file, then use bpadmin to restart udpclo.
FILES¶
No configuration files are needed.
ENVIRONMENT¶
No environment variables apply.
DIAGNOSTICS¶
The following diagnostics may be issued to the
ion.log log file:
- udpclo can't attach to BP.
- bpadmin has not yet initialized Bundle Protocol operations.
- No memory for UDP buffer in udpclo.
- ION system error. Check errtext, correct problem, and restart UDP.
- No such udp duct.
- No UDP outduct with duct name '*' has been added to the BP database. Use
bpadmin to stop the UDP convergence-layer protocol, add the
outduct, and then restart the UDP protocol.
- CLO task is already started for this engine.
- Redundant initiation of udpclo.
- CLO can't open UDP socket
- Operating system error. Check errtext, correct problem, and restart
udpclo.
- CLO write() error on socket
- Operating system error. Check errtext, correct problem, and restart
udpclo.
- Bundle is too big for UDP CLA.
- Configuration error: bundles that are too large for UDP transmission
(i.e., larger than 65535 bytes) are being enqueued for udpclo.
Change routing.
BUGS¶
Report bugs to <ion-bugs@korgano.eecs.ohiou.edu>
SEE ALSO¶
bpadmin(1),
bprc(5),
udpcli(1)