'\" t .\" Title: apcupsd-ups .\" Author: [see the "AUTHOR" section] .\" Generator: DocBook XSL Stylesheets vsnapshot .\" Date: 02/19/2024 .\" Manual: NUT Manual .\" Source: Network UPS Tools 2.8.1 .\" Language: English .\" .TH "APCUPSD\-UPS" "8" "02/19/2024" "Network UPS Tools 2\&.8\&.1" "NUT Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "NAME" apcupsd-ups \- Driver for apcupsd client access .SH "NOTE" .sp This man page only documents the specific features of the \fBapcupsd\-ups\fR driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&. .SH "DESCRIPTION" .sp This driver is a client to \fBapcupsd\fR (another UPS monitoring project)\&. .sp \fBapcupsd\-ups\fR acts as an \fBapcupsd\fR client, simply forwarding data\&. This can be useful in cases where both protocols are required in a network, or in case apcupsd has a required UPS access mode missing from NUT\&. .SH "EXTRA ARGUMENTS" .sp This driver supports the following optional settings in \fBnut.conf\fR(5): .PP \fBport\fR=[:] .RS 4 This is the name of a remote host running apcupsd (plus an optional port)\&. .RE .sp For instance: .sp .if n \{\ .RS 4 .\} .nf [apcupsd] driver = apcupsd\-ups port = localhost desc = "apcupsd client" .fi .if n \{\ .RE .\} .SH "BACKGROUND" .sp This driver was originally written in one evening to allow interoperating with \fBapcupsd\fR\&. .SH "SUPPORTED VARIABLES" .sp The following variables are translated from \fBapcupsd\fR to NUT\&. All times should be converted to seconds (please file a bug if you notice a mismatch in units)\&. .TS allbox tab(:); ltB ltB. T{ apcupsd variable T}:T{ NUT variable(s) T} .T& lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt lt. T{ .sp BCHARGE T}:T{ .sp battery\&.charge T} T{ .sp MBATTCHG T}:T{ .sp battery\&.charge\&.low T} T{ .sp RETPCT T}:T{ .sp battery\&.charge\&.restart T} T{ .sp BATTDATE T}:T{ .sp battery\&.date T} T{ .sp TIMELEFT T}:T{ .sp battery\&.runtime T} T{ .sp MINTIMEL T}:T{ .sp battery\&.runtime\&.low T} T{ .sp BATTV T}:T{ .sp battery\&.voltage T} T{ .sp NOMBATTV T}:T{ .sp battery\&.voltage\&.nominal T} T{ .sp LINEFREQ T}:T{ .sp input\&.frequency T} T{ .sp SENSE T}:T{ .sp input\&.sensitivity T} T{ .sp HITRANS T}:T{ .sp input\&.transfer\&.high T} T{ .sp LOTRANS T}:T{ .sp input\&.transfer\&.low T} T{ .sp LASTXFER T}:T{ .sp input\&.transfer\&.reason T} T{ .sp LINEV T}:T{ .sp input\&.voltage T} T{ .sp MAXLINEV T}:T{ .sp input\&.voltage\&.maximum T} T{ .sp MINLINEV T}:T{ .sp input\&.voltage\&.minimum T} T{ .sp NOMINV T}:T{ .sp input\&.voltage\&.nominal T} T{ .sp LINEFREQ T}:T{ .sp output\&.frequency T} T{ .sp OUTPUTV T}:T{ .sp output\&.voltage T} T{ .sp NOMOUTV T}:T{ .sp output\&.voltage\&.nominal T} T{ .sp DATE T}:T{ .sp ups\&.date, ups\&.time T} T{ .sp DSHUTD T}:T{ .sp ups\&.delay\&.shutdown T} T{ .sp DWAKE T}:T{ .sp ups\&.delay\&.start T} T{ .sp FIRMWARE T}:T{ .sp ups\&.firmware, ups\&.firmware\&.aux T} T{ .sp UPSNAME T}:T{ .sp ups\&.id T} T{ .sp LOADPCT T}:T{ .sp ups\&.load T} T{ .sp MANDATE T}:T{ .sp ups\&.mfr\&.date T} T{ .sp NOMPOWER T}:T{ .sp ups\&.realpower\&.nominal T} T{ .sp SERIALNO T}:T{ .sp ups\&.serial T} T{ .sp STATUS T}:T{ .sp ups\&.status T} T{ .sp ITEMP T}:T{ .sp ups\&.temperature T} T{ .sp STESTI T}:T{ .sp ups\&.test\&.interval T} T{ .sp SELFTEST T}:T{ .sp ups\&.test\&.result T} .TE .sp 1 .SH "LIMITATIONS" .sp Access to \fBapcupsd\fR is strictly read only: no commands can be issued\&. This stems from the design of \fBapcupsd\fR, where the settings are changed in \fBapctest\fR\&. In order to run \fBapctest\fR, \fBapcupsd\fR must be stopped (and it is \fBapcupsd\fR exposes the UPS to the network and to this NUT driver as its client)\&. .SH "AUTHOR" .sp Andreas Steinmetz .SH "SEE ALSO" .sp \fBups.conf\fR(5), \fBnutupsdrv\fR(8) .SS "Internet Resources:" .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} The NUT (Network UPS Tools) home page: https://www\&.networkupstools\&.org/ .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} The apcupsd home page: http://www\&.apcupsd\&.org/ .RE