'\" '\" Copyright (c) 1993 The Regents of the University of California. '\" Copyright (c) 1994-1996 Sun Microsystems, Inc. '\" '\" See the file "license.terms" for information on usage and redistribution '\" of this file, and for a DISCLAIMER OF ALL WARRANTIES. '\" .TH Tcl_LinkVar 3tcl 7.5 Tcl "Tcl Library Procedures" .\" The -*- nroff -*- definitions below are for supplemental macros used .\" in Tcl/Tk manual entries. .\" .\" .AP type name in/out ?indent? .\" Start paragraph describing an argument to a library procedure. .\" type is type of argument (int, etc.), in/out is either "in", "out", .\" or "in/out" to describe whether procedure reads or modifies arg, .\" and indent is equivalent to second arg of .IP (shouldn't ever be .\" needed; use .AS below instead) .\" .\" .AS ?type? ?name? .\" Give maximum sizes of arguments for setting tab stops. Type and .\" name are examples of largest possible arguments that will be passed .\" to .AP later. If args are omitted, default tab stops are used. .\" .\" .BS .\" Start box enclosure. From here until next .BE, everything will be .\" enclosed in one large box. .\" .\" .BE .\" End of box enclosure. .\" .\" .CS .\" Begin code excerpt. .\" .\" .CE .\" End code excerpt. .\" .\" .VS ?version? ?br? .\" Begin vertical sidebar, for use in marking newly-changed parts .\" of man pages. The first argument is ignored and used for recording .\" the version when the .VS was added, so that the sidebars can be .\" found and removed when they reach a certain age. If another argument .\" is present, then a line break is forced before starting the sidebar. .\" .\" .VE .\" End of vertical sidebar. .\" .\" .DS .\" Begin an indented unfilled display. .\" .\" .DE .\" End of indented unfilled display. .\" .\" .SO ?manpage? .\" Start of list of standard options for a Tk widget. The manpage .\" argument defines where to look up the standard options; if .\" omitted, defaults to "options". The options follow on successive .\" lines, in three columns separated by tabs. .\" .\" .SE .\" End of list of standard options for a Tk widget. .\" .\" .OP cmdName dbName dbClass .\" Start of description of a specific option. cmdName gives the .\" option's name as specified in the class command, dbName gives .\" the option's name in the option database, and dbClass gives .\" the option's class in the option database. .\" .\" .UL arg1 arg2 .\" Print arg1 underlined, then print arg2 normally. .\" .\" .QW arg1 ?arg2? .\" Print arg1 in quotes, then arg2 normally (for trailing punctuation). .\" .\" .PQ arg1 ?arg2? .\" Print an open parenthesis, arg1 in quotes, then arg2 normally .\" (for trailing punctuation) and then a closing parenthesis. .\" .\" # Set up traps and other miscellaneous stuff for Tcl/Tk man pages. .if t .wh -1.3i ^B .nr ^l \n(.l .ad b .\" # Start an argument description .de AP .ie !"\\$4"" .TP \\$4 .el \{\ . ie !"\\$2"" .TP \\n()Cu . el .TP 15 .\} .ta \\n()Au \\n()Bu .ie !"\\$3"" \{\ \&\\$1 \\fI\\$2\\fP (\\$3) .\".b .\} .el \{\ .br .ie !"\\$2"" \{\ \&\\$1 \\fI\\$2\\fP .\} .el \{\ \&\\fI\\$1\\fP .\} .\} .. .\" # define tabbing values for .AP .de AS .nr )A 10n .if !"\\$1"" .nr )A \\w'\\$1'u+3n .nr )B \\n()Au+15n .\" .if !"\\$2"" .nr )B \\w'\\$2'u+\\n()Au+3n .nr )C \\n()Bu+\\w'(in/out)'u+2n .. .AS Tcl_Interp Tcl_CreateInterp in/out .\" # BS - start boxed text .\" # ^y = starting y location .\" # ^b = 1 .de BS .br .mk ^y .nr ^b 1u .if n .nf .if n .ti 0 .if n \l'\\n(.lu\(ul' .if n .fi .. .\" # BE - end boxed text (draw box now) .de BE .nf .ti 0 .mk ^t .ie n \l'\\n(^lu\(ul' .el \{\ .\" Draw four-sided box normally, but don't draw top of .\" box if the box started on an earlier page. .ie !\\n(^b-1 \{\ \h'-1.5n'\L'|\\n(^yu-1v'\l'\\n(^lu+3n\(ul'\L'\\n(^tu+1v-\\n(^yu'\l'|0u-1.5n\(ul' .\} .el \}\ \h'-1.5n'\L'|\\n(^yu-1v'\h'\\n(^lu+3n'\L'\\n(^tu+1v-\\n(^yu'\l'|0u-1.5n\(ul' .\} .\} .fi .br .nr ^b 0 .. .\" # VS - start vertical sidebar .\" # ^Y = starting y location .\" # ^v = 1 (for troff; for nroff this doesn't matter) .de VS .if !"\\$2"" .br .mk ^Y .ie n 'mc \s12\(br\s0 .el .nr ^v 1u .. .\" # VE - end of vertical sidebar .de VE .ie n 'mc .el \{\ .ev 2 .nf .ti 0 .mk ^t \h'|\\n(^lu+3n'\L'|\\n(^Yu-1v\(bv'\v'\\n(^tu+1v-\\n(^Yu'\h'-|\\n(^lu+3n' .sp -1 .fi .ev .\} .nr ^v 0 .. .\" # Special macro to handle page bottom: finish off current .\" # box/sidebar if in box/sidebar mode, then invoked standard .\" # page bottom macro. .de ^B .ev 2 'ti 0 'nf .mk ^t .if \\n(^b \{\ .\" Draw three-sided box if this is the box's first page, .\" draw two sides but no top otherwise. .ie !\\n(^b-1 \h'-1.5n'\L'|\\n(^yu-1v'\l'\\n(^lu+3n\(ul'\L'\\n(^tu+1v-\\n(^yu'\h'|0u'\c .el \h'-1.5n'\L'|\\n(^yu-1v'\h'\\n(^lu+3n'\L'\\n(^tu+1v-\\n(^yu'\h'|0u'\c .\} .if \\n(^v \{\ .nr ^x \\n(^tu+1v-\\n(^Yu \kx\h'-\\nxu'\h'|\\n(^lu+3n'\ky\L'-\\n(^xu'\v'\\n(^xu'\h'|0u'\c .\} .bp 'fi .ev .if \\n(^b \{\ .mk ^y .nr ^b 2 .\} .if \\n(^v \{\ .mk ^Y .\} .. .\" # DS - begin display .de DS .RS .nf .sp .. .\" # DE - end display .de DE .fi .RE .sp .. .\" # SO - start of list of standard options .de SO 'ie '\\$1'' .ds So \\fBoptions\\fR 'el .ds So \\fB\\$1\\fR .SH "STANDARD OPTIONS" .LP .nf .ta 5.5c 11c .ft B .. .\" # SE - end of list of standard options .de SE .fi .ft R .LP See the \\*(So manual entry for details on the standard options. .. .\" # OP - start of full description for a single option .de OP .LP .nf .ta 4c Command-Line Name: \\fB\\$1\\fR Database Name: \\fB\\$2\\fR Database Class: \\fB\\$3\\fR .fi .IP .. .\" # CS - begin code excerpt .de CS .RS .nf .ta .25i .5i .75i 1i .. .\" # CE - end code excerpt .de CE .fi .RE .. .\" # UL - underline word .de UL \\$1\l'|0\(ul'\\$2 .. .\" # QW - apply quotation marks to word .de QW .ie '\\*(lq'"' ``\\$1''\\$2 .\"" fix emacs highlighting .el \\*(lq\\$1\\*(rq\\$2 .. .\" # PQ - apply parens and quotation marks to word .de PQ .ie '\\*(lq'"' (``\\$1''\\$2)\\$3 .\"" fix emacs highlighting .el (\\*(lq\\$1\\*(rq\\$2)\\$3 .. .\" # QR - quoted range .de QR .ie '\\*(lq'"' ``\\$1''\\-``\\$2''\\$3 .\"" fix emacs highlighting .el \\*(lq\\$1\\*(rq\\-\\*(lq\\$2\\*(rq\\$3 .. .\" # MT - "empty" string .de MT .QW "" .. .BS .SH NAME Tcl_LinkVar, Tcl_UnlinkVar, Tcl_UpdateLinkedVar \- link Tcl variable to C variable .SH SYNOPSIS .nf \fB#include \fR .sp int \fBTcl_LinkVar\fR(\fIinterp, varName, addr, type\fR) .sp \fBTcl_UnlinkVar\fR(\fIinterp, varName\fR) .sp \fBTcl_UpdateLinkedVar\fR(\fIinterp, varName\fR) .SH ARGUMENTS .AS Tcl_Interp writable .AP Tcl_Interp *interp in Interpreter that contains \fIvarName\fR. Also used by \fBTcl_LinkVar\fR to return error messages. .AP "const char" *varName in Name of global variable. .AP char *addr in Address of C variable that is to be linked to \fIvarName\fR. .AP int type in Type of C variable. Must be one of \fBTCL_LINK_INT\fR, \fBTCL_LINK_UINT\fR, \fBTCL_LINK_CHAR\fR, \fBTCL_LINK_UCHAR\fR, \fBTCL_LINK_SHORT\fR, \fBTCL_LINK_USHORT\fR, \fBTCL_LINK_LONG\fR, \fBTCL_LINK_ULONG\fR, \fBTCL_LINK_WIDE_INT\fR, \fBTCL_LINK_WIDE_UINT\fR, \fBTCL_LINK_FLOAT\fR, \fBTCL_LINK_DOUBLE\fR, \fBTCL_LINK_BOOLEAN\fR, or \fBTCL_LINK_STRING\fR, optionally OR'ed with \fBTCL_LINK_READ_ONLY\fR to make Tcl variable read-only. .BE .SH DESCRIPTION .PP \fBTcl_LinkVar\fR uses variable traces to keep the Tcl variable named by \fIvarName\fR in sync with the C variable at the address given by \fIaddr\fR. Whenever the Tcl variable is read the value of the C variable will be returned, and whenever the Tcl variable is written the C variable will be updated to have the same value. \fBTcl_LinkVar\fR normally returns \fBTCL_OK\fR; if an error occurs while setting up the link (e.g. because \fIvarName\fR is the name of array) then \fBTCL_ERROR\fR is returned and the interpreter's result contains an error message. .PP The \fItype\fR argument specifies the type of the C variable, and must have one of the following values, optionally OR'ed with \fBTCL_LINK_READ_ONLY\fR: .TP \fBTCL_LINK_INT\fR The C variable is of type \fBint\fR. Any value written into the Tcl variable must have a proper integer form acceptable to \fBTcl_GetIntFromObj\fR; attempts to write non-integer values into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_UINT\fR The C variable is of type \fBunsigned int\fR. Any value written into the Tcl variable must have a proper unsigned integer form acceptable to \fBTcl_GetWideIntFromObj\fR and in the platform's defined range for the \fBunsigned int\fR type; attempts to write non-integer values (or values outside the range) into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_CHAR\fR The C variable is of type \fBchar\fR. Any value written into the Tcl variable must have a proper integer form acceptable to \fBTcl_GetIntFromObj\fR and be in the range of the \fBchar\fR datatype; attempts to write non-integer or out-of-range values into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_UCHAR\fR The C variable is of type \fBunsigned char\fR. Any value written into the Tcl variable must have a proper unsigned integer form acceptable to \fBTcl_GetIntFromObj\fR and in the platform's defined range for the \fBunsigned char\fR type; attempts to write non-integer values (or values outside the range) into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_SHORT\fR The C variable is of type \fBshort\fR. Any value written into the Tcl variable must have a proper integer form acceptable to \fBTcl_GetIntFromObj\fR and be in the range of the \fBshort\fR datatype; attempts to write non-integer or out-of-range values into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_USHORT\fR The C variable is of type \fBunsigned short\fR. Any value written into the Tcl variable must have a proper unsigned integer form acceptable to \fBTcl_GetIntFromObj\fR and in the platform's defined range for the \fBunsigned short\fR type; attempts to write non-integer values (or values outside the range) into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_LONG\fR The C variable is of type \fBlong\fR. Any value written into the Tcl variable must have a proper integer form acceptable to \fBTcl_GetLongFromObj\fR; attempts to write non-integer or out-of-range values into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_ULONG\fR The C variable is of type \fBunsigned long\fR. Any value written into the Tcl variable must have a proper unsigned integer form acceptable to \fBTcl_GetWideIntFromObj\fR and in the platform's defined range for the \fBunsigned long\fR type; attempts to write non-integer values (or values outside the range) into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_DOUBLE\fR The C variable is of type \fBdouble\fR. Any value written into the Tcl variable must have a proper real form acceptable to \fBTcl_GetDoubleFromObj\fR; attempts to write non-real values into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer or real representations (like the empty string, '.', '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_FLOAT\fR The C variable is of type \fBfloat\fR. Any value written into the Tcl variable must have a proper real form acceptable to \fBTcl_GetDoubleFromObj\fR and must be within the range acceptable for a \fBfloat\fR; attempts to write non-real values (or values outside the range) into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer or real representations (like the empty string, '.', '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_WIDE_INT\fR The C variable is of type \fBTcl_WideInt\fR (which is an integer type at least 64-bits wide on all platforms that can support it.) Any value written into the Tcl variable must have a proper integer form acceptable to \fBTcl_GetWideIntFromObj\fR; attempts to write non-integer values into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_WIDE_UINT\fR The C variable is of type \fBTcl_WideUInt\fR (which is an unsigned integer type at least 64-bits wide on all platforms that can support it.) Any value written into the Tcl variable must have a proper unsigned integer form acceptable to \fBTcl_GetWideIntFromObj\fR (it will be cast to unsigned); .\" FIXME! Use bignums instead. attempts to write non-integer values into \fIvarName\fR will be rejected with Tcl errors. Incomplete integer representations (like the empty string, '+', '-' or the hex/octal/binary prefix) are accepted as if they are valid too. .TP \fBTCL_LINK_BOOLEAN\fR The C variable is of type \fBint\fR. If its value is zero then it will read from Tcl as .QW 0 ; otherwise it will read from Tcl as .QW 1 . Whenever \fIvarName\fR is modified, the C variable will be set to a 0 or 1 value. Any value written into the Tcl variable must have a proper boolean form acceptable to \fBTcl_GetBooleanFromObj\fR; attempts to write non-boolean values into \fIvarName\fR will be rejected with Tcl errors. .TP \fBTCL_LINK_STRING\fR The C variable is of type \fBchar *\fR. If its value is not NULL then it must be a pointer to a string allocated with \fBTcl_Alloc\fR or \fBckalloc\fR. Whenever the Tcl variable is modified the current C string will be freed and new memory will be allocated to hold a copy of the variable's new value. If the C variable contains a NULL pointer then the Tcl variable will read as .QW NULL . .PP If the \fBTCL_LINK_READ_ONLY\fR flag is present in \fItype\fR then the variable will be read-only from Tcl, so that its value can only be changed by modifying the C variable. Attempts to write the variable from Tcl will be rejected with errors. .PP \fBTcl_UnlinkVar\fR removes the link previously set up for the variable given by \fIvarName\fR. If there does not exist a link for \fIvarName\fR then the procedure has no effect. .PP \fBTcl_UpdateLinkedVar\fR may be invoked after the C variable has changed to force the Tcl variable to be updated immediately. In many cases this procedure is not needed, since any attempt to read the Tcl variable will return the latest value of the C variable. However, if a trace has been set on the Tcl variable (such as a Tk widget that wishes to display the value of the variable), the trace will not trigger when the C variable has changed. \fBTcl_UpdateLinkedVar\fR ensures that any traces on the Tcl variable are invoked. .PP Note that, as with any call to a Tcl interpreter, \fBTcl_UpdateLinkedVar\fR must be called from the same thread that created the interpreter. The safest mechanism is to ensure that the C variable is only ever updated from the same thread that created the interpreter (possibly in response to an event posted with \fBTcl_ThreadQueueEvent\fR), but when it is necessary to update the variable in a separate thread, it is advised that \fBTcl_AsyncMark\fR be used to indicate to the thread hosting the interpreter that it is ready to run \fBTcl_UpdateLinkedVar\fR. .SH "SEE ALSO" Tcl_TraceVar(3tcl) .SH KEYWORDS boolean, integer, link, read-only, real, string, trace, variable