.SH "NAME"
modbus_rtu_get_rts \- get the current RTS mode in RTU
.SH "SYNOPSIS"
.sp
\fBint modbus_rtu_get_rts(modbus_t *\fR\fB\fIctx\fR\fR\fB);\fR
.SH "DESCRIPTION"
.sp
The \fBmodbus_rtu_get_rts()\fR function shall get the current Request To Send mode of the libmodbus context \fIctx\fR\&. The possible returned values are:
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
MODBUS_RTU_RTS_NONE
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
MODBUS_RTU_RTS_UP
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
MODBUS_RTU_RTS_DOWN
.RE
.sp
This function can only be used with a context using a RTU backend\&.
.SH "RETURN VALUE"
.sp
The function shall return the current RTS mode if successful\&. Otherwise it shall return \-1 and set errno\&.
.SH "ERRORS"
.PP
\fBEINVAL\fR
.RS 4
The libmodbus backend is not RTU\&.
.RE
.SH "SEE ALSO"