.\" DO NOT MODIFY THIS FILE! It was generated by help2man 1.44.1. .TH MEASURE "1" "September 2014" "spotread" "User Commands" .SH NAME Measure \- Read Print Spot values. .SH DESCRIPTION Measure spot values, Version 1.6.3 .SH SYNOPSIS .B spotread .RB [\-options]\ [logfile] .TP \fB\-v\fR Verbose mode .TP \fB\-s\fR Print spectrum for each reading .TP \fB\-S\fR Plot spectrum for each reading .TP \fB\-c\fR listno Set communication port from the following list (default 1) .IP ** No ports found ** .TP \fB\-t\fR Use transmission measurement mode .TP \fB\-e\fR Use emissive measurement mode (absolute results) .TP \fB\-eb\fR Use display white brightness relative measurement mode .TP \fB\-ew\fR Use display white point relative chromatically adjusted mode .TP \fB\-p\fR Use telephoto measurement mode (absolute results) .TP \fB\-pb\fR Use projector white brightness relative measurement mode .TP \fB\-pw\fR Use projector white point relative chromatically adjusted mode .TP \fB\-a\fR Use ambient measurement mode (absolute results) .TP \fB\-f\fR Use ambient flash measurement mode (absolute results) .TP \fB\-I\fR illum Set simulated instrument illumination using FWA (def \fB\-i\fR illum): M0, M1, M2, A, C, D50, D50M2, D65, F5, F8, F10 or file.sp] .TP \fB\-i\fR illum Choose illuminant for computation of CIE XYZ from spectral data & FWA: A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp .TP \fB\-Q\fR observ Choose CIE Observer for spectral data or CCSS instrument: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 (Choose FWA during operation) .TP \fB\-F\fR filter Set filter configuration (if aplicable): .TP n None .TP p Polarising filter .TP 6 D65 .TP u U.V. Cut .TP \fB\-E\fR extrafilterfile Apply extra filter compensation file .TP \fB\-x\fR Display Yxy instead of Lab .TP \fB\-h\fR Display LCh instead of Lab .TP \fB\-V\fR Show running average and std. devation from ref. .TP \fB\-T\fR Display correlated color temperatures and CRI .TP \fB\-N\fR Disable auto calibration of instrument .TP \fB\-H\fR Start in high resolution spectrum mode (if available) .TP \fB\-X\fR file.ccmx Apply Colorimeter Correction Matrix .TP \fB\-X\fR file.ccss Use Colorimeter Calibration Spectral Samples for calibration .TP \fB\-Y\fR r|n Override refresh, non\-refresh display mode .TP \fB\-Y\fR R:rate Override measured refresh rate with rate Hz .TP \fB\-Y\fR A Use non\-adaptive integration time mode (if available). .TP \fB\-W\fR n|h|x Override serial port flow control: n = none, h = HW, x = Xon/Xoff .TP \fB\-D\fR [level] Print debug diagnostics to stderr .TP logfile Optional file to save reading results as text